Dell PowerEdge FX2 Owner's manual

Category
Network equipment chassis
Type
Owner's manual
Dell PowerEdge FX2 and FX2s Enclosure
Owner's Manual
Regulatory Model: E24S
Regulatory Type: E24S001
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell
â„¢
and the Dell logo are trademarks of Dell Inc. in the United States and/or other
jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2015 - 03
Rev. A02
Contents
1 About your Dell PowerEdge FX2/FX2s..............................................................6
Terms used in the document................................................................................................................6
Sled slot numbering.............................................................................................................................. 8
Front panel features and indicators—PowerEdge FX2/FX2s............................................................... 9
Diagnostic indicators.....................................................................................................................10
Power button functions.................................................................................................................11
KVM features.................................................................................................................................. 12
Back panel features and indicators—PowerEdge FX2s and FX2........................................................12
Power supply unit indicators.........................................................................................................14
I/O module indicators................................................................................................................... 15
CMC module..................................................................................................................................16
Cooling fan indicator codes................................................................................................................18
Configuration wizard...........................................................................................................................19
System messages................................................................................................................................ 19
Documentation matrix........................................................................................................................20
Quick Resource Locator..................................................................................................................... 21
2 Initial system configuration..............................................................................22
Before you begin.................................................................................................................................22
Setting up your PowerEdge FX2/FX2s................................................................................................22
Logging in to the CMC........................................................................................................................23
3 PowerEdge FX2/FX2s mapping configurations............................................ 24
LAN On Motherboard network...........................................................................................................24
Supported I/O modules................................................................................................................ 24
I/O module port mapping—four-bay chassis.............................................................................. 25
I/O module port mapping—eight-bay chassis.............................................................................26
I/O module port mapping—six-bay chassis.................................................................................27
I/O module port mapping—two-bay chassis...............................................................................28
I/O module port mapping—three-bay chassis............................................................................ 28
I/O module and PCIe mezzanine card configuration guidelines..................................................... 29
Configuring network settings for the I/O module.............................................................................30
Expansion bus..................................................................................................................................... 30
PCIe expansion slot mapping ......................................................................................................30
PCIe slot mapping from compute sleds...................................................................................... 30
PCIe slot mapping from compute sleds mapped to storage sleds.............................................32
Managing PCIe slots......................................................................................................................34
Internal management network...........................................................................................................34
3
4 Installing and removing PowerEdge FX2/FX2s enclosure
components............................................................................................................35
Customer and field replaceable units—PowerEdge FX2/FX2s..........................................................35
Safety instructions...............................................................................................................................35
Before working inside your system.................................................................................................... 36
After working inside your system....................................................................................................... 36
Recommended tools.......................................................................................................................... 36
System cover.......................................................................................................................................36
Removing the system cover......................................................................................................... 36
Installing the system cover............................................................................................................37
Sleds.....................................................................................................................................................38
Removing a compute sled............................................................................................................38
Installing a compute sled..............................................................................................................39
Removing a storage sled.............................................................................................................. 40
Installing a storage sled.................................................................................................................42
Inside the system.................................................................................................................................43
CMC module....................................................................................................................................... 45
Removing the CMC module......................................................................................................... 45
Installing the CMC module...........................................................................................................46
I/O module.......................................................................................................................................... 47
Removing an I/O module..............................................................................................................47
Installing an I/O module............................................................................................................... 48
PCIe module....................................................................................................................................... 48
Removing a PCIe module.............................................................................................................49
Installing a PCIe module...............................................................................................................50
Expansion cards.................................................................................................................................. 50
Expansion card types and form factor......................................................................................... 50
Expansion card operational power status.....................................................................................51
PCIe module indicators................................................................................................................. 51
Removing an expansion card........................................................................................................52
Installing an expansion card..........................................................................................................53
Power supply units..............................................................................................................................53
Removing a power supply unit..................................................................................................... 54
Installing a power supply unit....................................................................................................... 55
Cooling fans........................................................................................................................................ 55
Removing a cooling fan................................................................................................................ 55
Installing a cooling fan.................................................................................................................. 57
Cooling-fan cage................................................................................................................................ 57
Removing the cooling-fan cage...................................................................................................57
Installing the cooling-fan cage.....................................................................................................59
PCIe switch board...............................................................................................................................59
4
Removing the PCIe switch board.................................................................................................59
Installing the PCIe switch board................................................................................................... 61
Fan interface board............................................................................................................................. 61
Removing the fan interface board................................................................................................62
Installing the fan interface board..................................................................................................63
Interposer module.............................................................................................................................. 64
Removing the bottom interposer module................................................................................... 65
Installing the bottom interposer module.....................................................................................68
Removing the top interposer module..........................................................................................69
Installing the top interposer module............................................................................................ 72
Midplane assembly..............................................................................................................................73
Removing the midplane assembly................................................................................................73
Installing the midplane assembly..................................................................................................75
Power interposer board................................................................................................................ 76
Control panel.......................................................................................................................................78
Removing the control panel......................................................................................................... 78
Installing the control panel...........................................................................................................80
KVM panel........................................................................................................................................... 80
Removing the KVM panel............................................................................................................. 80
Installing the KVM panel................................................................................................................82
5 Troubleshooting your system..........................................................................84
Safety first—for you and your system................................................................................................ 84
Responding to a systems management alert message.....................................................................84
Troubleshooting external connections..............................................................................................84
Troubleshooting a damaged enclosure.............................................................................................84
Troubleshooting enclosure components.......................................................................................... 85
Troubleshooting a wet enclosure................................................................................................ 85
Troubleshooting power supply units............................................................................................85
Troubleshooting cooling problems............................................................................................. 86
Troubleshooting cooling fans...................................................................................................... 86
Troubleshooting expansion cards................................................................................................ 87
Troubleshooting I/O modules............................................................................................................87
6 Technical specifications—PowerEdge FX2/FX2s......................................... 89
7 Getting help.........................................................................................................94
Contacting Dell................................................................................................................................... 94
Locating your system Service Tag......................................................................................................94
Quick Resource Locator.....................................................................................................................94
5
1
About your Dell PowerEdge FX2/FX2s
The Dell PowerEdge FX2/FX2s is a 2U enclosure that can support up to four half-width compute sleds, up
to eight quarter-width compute sleds, up to two full-width compute sleds, or a mix of compute sled
types. The PowerEdge FX2s enclosure also supports half-width storage sleds mapped to the compute
sleds.
NOTE: For information on mapping configurations from storage sleds to compute sleds in the
PowerEdge FX2s enclosure, see the Dell PowerEdge FD332 Owner’s Manual at dell.com/
poweredgemanuals.
NOTE: PowerEdge FX2 does not support storage sleds.
For the enclosure and sleds to function as a system, you must install the sleds in the enclosure. Enclosure
components like power supply units, fan modules, Chassis Management Controller (CMC) module, KVM
panel, and I/O modules for external network connectivity are shared resources of the sleds installed in
the enclosure.
PowerEdge FX2s supports eight low-profile PCIe slots assigned to the compute sleds in the enclosure.
NOTE: PowerEdge FX2 does not support PCIe slots.
Terms used in the document
The following table describes the terms used in this document.
Term Description
Enclosure, chassis, or system Refers to the Dell PowerEdge FX2 or FX2s system.
Storage sled Refers to the PowerEdge FD332 sled, which supports up to sixteen
2.5 inch hot-swap hard drives/SSDs in a drive drawer.
NOTE: PowerEdge FX2 does not support the PowerEdge
FD332 storage sled.
Compute sled Refers to the half-width, quarter-width, or full-width servers, to
which the storage sleds are mapped.
NOTE: The PowerEdge FM120x4 half-width compute sled
does not support the storage sled.
NOTE: For information on mapping of storage sleds to
compute sleds in PowerEdge FX2s, see the Dell PowerEdge
FD332 Owner’s Manual at dell.com/poweredgemanuals.
6
Term Description
Four-bay chassis Refers to the PowerEdge FX2/FX2s enclosure configuration that
supports up to four half-width compute sleds.
NOTE: In PowerEdge FX2s, the four-bay chassis configuration
supports a combination of half-width compute and storage
sleds. It supports a maximum of three storage sleds mapped
to a compute sled.
Eight-bay chassis Refers to the PowerEdge FX2/FX2s enclosure configuration that
supports up to eight quarter-width compute sleds.
Two-bay chassis Refers to the PowerEdge FX2/FX2s enclosure configuration that up
to supports two full-width compute sleds.
Three-bay chassis Refers to the PowerEdge FX2/FX2s enclosure configuration that
supports one full-width compute sled and up to two half-width
compute sleds.
NOTE: In PowerEdge FX2s, this configuration also supports up
to two half-width storage sleds mapped to one full-width
compute sled.
Six-bay chassis Refers to the PowerEdge FX2/FX2s enclosure configuration that
supports up to four quarter-width compute sleds and up to two
half-width compute sleds.
NOTE: In PowerEdge FX2s, this configuration also supports up
to two half-width storage sleds mapped to up to four quarter-
width compute sleds.
I/O module Refers to an Ethernet pass-through module or switch module
installed in the enclosure.
Expansion card Refers to low-profile PCIe cards installed in the enclosure that
provide I/O expansion.
Warm swap A slot is considered warm-swap if the sled associated with a
component in that slot must be turned off before adding or
replacing the component. However, the enclosure and the rest of
the sleds remain powered on.
Hot swap A component in the enclosure is considered as hot swap if it can
be replaced or installed while the enclosure and sleds are powered
on.
7
Sled slot numbering
Figure 1. Sled slot numbering—four-bay chassis
Figure 2. Sled slot numbering—eight-bay chassis
Figure 3. Sled slot numbering—two-bay chassis
Figure 4. Sled slot numbering — six-bay chassis
8
Figure 5. Sled slot numbering—three-bay chassis
Front panel features and indicators—PowerEdge FX2/
FX2s
Figure 6. Front panel features and indicators—PowerEdge FX2/FX2s
Item Indicator, Button, or
Connector
Icon Description
1 System identification
button
The identification buttons on the front and
back panels can be used to locate a particular
system within a rack. When one of these
buttons is pressed, the system status indicator
on the back flashes until one of the buttons is
pressed again.
Press to toggle the system ID on and off.
2 Enclosure power-on
indicator, power
button
The power-on indicator lights when the
enclosure power is on. The power button
controls the power supply output to the
system. For more information, see Power
Button Functions.
3 Diagnostic indicators The diagnostic indicators light up to display
error status. For more information, see
Diagnostic Indicators.
9
Item Indicator, Button, or
Connector
Icon Description
4 KVM select button Enables you to map the KVM to the sleds.
5 Sleds PowerEdge FX2/FX2s supports up to:
• four half-width compute sleds, or
• eight quarter-width compute sleds, or
• two full-width compute sleds, or
• four quarter-width compute sleds and
two half-width compute sleds, or
• one full-width compute sled and up to
two half-width compute sleds
NOTE: PowerEdge FX2s supports a
combination of compute and storage
sleds. For information on mapping of
storage sleds to compute sleds in
PowerEdge FX2s, see the Dell
PowerEdge FD332 Owner's Manual at
dell.com/poweredgemanuals.
6 Video connector Enables you to connect a monitor to the
system.
7 USB connector Enables you to connect a keyboard or mouse
to the system.
Diagnostic indicators
The diagnostic indicators on the system front panel display error status during system startup.
NOTE: No diagnostic indicators are lit when the system is switched off. To start the system, plug it
into a working power source and press the power button.
The following table describes the system conditions and possible corrective actions associated with the
diagnostic indicators.
Table 1.
Health indicator
Condition Corrective Action
If the system is on, and in
good health, the indicator
lights solid blue.
None required.
The indicator blinks amber if
the system is on or in
standby, and any error exists
(for example, a failed fan or
hard drive)
See the CMC Chassis Log or system messages for the
specific issue.
10
Health indicator
Electrical indicator
Condition Corrective Action
The indicator blinks amber if
the system experiences an
electrical error (for example,
voltage out of range, or a
failed power supply or
voltage regulator).
See the CMC Chassis Log or system messages for the
specific issue. If it is due to a problem with the power
supply, check the LED on the power supply. Reseat the
power supply by removing and reinstalling it. If the problem
persists, see Getting Help.
Temperature indicator
Condition Corrective Action
The indicator blinks amber if
the system experiences a
thermal error (for example, a
temperature out of range or
fan failure).
Ensure that none of the following conditions exist:
• A cooling fan is removed or has failed.
• The system cover, cooling shroud, EMI filler panel,
memory-module blank, or back-filler bracket is
removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See Getting Help.
PCIe indicator
Condition Corrective Action
The indicator blinks amber if
a PCIe card experiences an
error.
Restart the sled. Update any required drivers for the PCIe
card. Reinstall the card. If the problem persists, see Getting
Help.
Power button functions
The following section describes the different functions of the power button on your PowerEdge FX2/FX2s
enclosure.
Chassis power
button and chassis
power button LED
The chassis power button is used to control power to the chassis and the
sleds. The chassis power button LED indicates the status of power to the chassis
and the sleds:
• If the LED is OFF, power to the chassis and the sleds is turned off.
• If the LED is ON, power to the chassis and the sleds in turned on.
Powering on
the chassis and
sleds
Press the chassis power button and the chassis power button LED changes from
OFF to ON. If pressing the chassis power button does not change the power
button LED from OFF to ON, see the troubleshooting section.
11
Powering off
the chassis and
sleds
For a graceful shutdown of all the sleds and the chassis, press and hold the chassis
power button for 4 to 10 seconds and release it.
NOTE: Depending on the status of the sleds, graceful shutdown may not be
possible. You may opt for a forced shutdown by pressing and holding the
chassis power button for more than 10 seconds.
KVM features
• Local KVM access can be remotely disabled on the enclosure by using the CMC interface.
• One VGA connector—The KVM supports a video display resolution range from 640 × 480 at 60 Hz up
to 1280 × 1024 × 65,000 colors (non-interlaced) at 75 Hz.
• One USB port for keyboard or mouse.
• The KVM provides access to the compute sleds. You can access one compute sled at a time by using
the KVM select button.
Back panel features and indicators—PowerEdge FX2s and
FX2
Figure 7. Back panel features and indicators—PowerEdge FX2s
12
Figure 8. Back panel features and indicators—PowerEdge FX2
Item Indicator, Button, or
Connector
Description
1 Serial connector DB-9 serial connector for CMC configuration.
2 Ethernet connector Gb1 Connects the network cable from the management
system to the CMC.
3 Ethernet connector
STK/Gb2 (stack)
Used for daisy-chaining CMCs in separate enclosures.
NOTE: This port can also be used for CMC NIC
failover.
4 System identification button The identification buttons on the front and back panels
can be used to locate a particular system within a rack.
When one of these buttons is pressed, the system status
indicator on the back flashes until one of the buttons is
pressed again.
Press to toggle the system ID on and off.
5 Low-profile PCIe expansion
slots (8)
Enable you to connect up to eight low-profile PCIe
expansion cards.
NOTE: PowerEdge FX2 does not support PCIe
expansion slots and has a filler panel.
6 Power supply unit (PSU1) 1100 W (1050 W for low line)
1600 W (800 W for low line)
2000 W (1000 W for low line)
7 Power supply unit (PSU2) 1100 W (1050 W for low line)
1600 W (800 W for low line)
2000 W (1000 W for low line)
13
Item Indicator, Button, or
Connector
Description
8 I/O module (2) Provides Ethernet connectivity to the compute sleds in the
enclosure.
9 I/O module ports Network interface for I/O modules.
10 I/O module indicators Two indicators for:
• Status
• Power
Power supply unit indicators
Each AC power supply unit (PSU) has an illuminated translucent handle that serves as an indicator to
show whether power is present or whether a power fault has occurred. The AC PSUs must be connected
to a Power Distribution Unit (PDU) or to an electrical outlet.
Figure 9. PSU indicators
1. AC PSU status indicator/handle
NOTE: The 2000 W PSU power cable connector is different from the connector shown in the image
above.
The PSU indicators provide the following information:
Convent
ion
Power indicator
pattern
Condition
A Green In standby mode, the handle lights green indicating that a valid power
source is connected to the PSU and that the PSU is operational.
B Flashing amber Indicates a problem with the PSU.
14
Convent
ion
Power indicator
pattern
Condition
CAUTION: When correcting a PSU mismatch, replace only the PSU
with the flashing indicator. Swapping the opposite PSU to make a
matched pair can result in an error condition and unexpected
system shutdown. To change from a High Output configuration to
a Low Output configuration or vice versa, you must power down
the system.
CAUTION: AC power supplies support both 220 V and 110 V input
voltages. When two identical power supplies receive different
input voltages, they can output different wattages, and trigger a
mismatch.
CAUTION: All power supplies used must be of the same type and
have the same maximum output power.
C Not lit Power is not connected.
I/O module indicators
Figure 10. I/O module indicators (pass-through module)
Figure 11. I/O module indicators (switch module)
1. power indicator 2. status indicator
The indicators provide the following information:
Indicator Description
Power indicator
Green The I/O module is operating normally.
Off The I/O module is powered off.
15
Indicator Description
Status indicator
Blue The I/O module is operating normally.
Blinking Blue The CMC is identifying the I/O module.
Blinking Amber The I/O module is in a fault condition.
Off The I/O module is powered off, or booting is in progress.
For more information, see the I/O module documentation at dell.com/poweredgemanuals.
CMC module
1 DB-9 serial connector for local configuration 2 Ethernet connector Gb1
3 link indicator 4 activity indicator
5 Ethernet connector STK/Gb2 (stack)
NOTE: This port can also be used for
CMC NIC failover.
6 system identification button
CMC indicators
The CMC indicators on the back panel of the enclosure provide the following information:
Indicator Description
System
identification
button
The identification buttons on the front and back panels can be used to locate a
particular system within a rack. When one of these buttons is pressed, the system
status indicator on the back flashes until one of the buttons is pressed again. Press
to toggle the system ID on and off.
Status indicator
Blue The CMC is active and operating normally.
Amber The chassis is in fault condition.
CMC features
The CMC provides the following multiple systems management functions:
• Enclosure-level real-time automatic power and thermal management:
– Monitors system power requirements.
– Reports real-time power consumption, which includes logging high and low points with a time
stamp.
16
– Supports setting an optional enclosure Maximum Power Limit, which either alerts or takes actions,
such as throttling compute sleds and/or preventing the power up of new compute sleds to keep
the enclosure under the defined maximum power limit.
– Monitors and automatically controls cooling fans based on actual ambient and internal
temperature measurements.
– Provides comprehensive enclosure inventory and status or error reporting.
• Centralized configuration of the following:
– The enclosure’s network and security settings.
– Power redundancy and power ceiling settings.
– I/O module and iDRAC network settings.
– First boot device on the compute sleds.
– Checks I/O path consistency for the I/O module, PCIe slots, and sleds and disables components if
necessary to protect the system hardware.
– User access security.
The CMC module is hot-swappable. During the period that the CMC module is removed:
• you cannot turn on newly installed compute sleds
• existing compute sleds cannot be accessed remotely
• enclosure cooling fans run at maximum speed for thermal protection of the components
Daisy-chain CMC network connection
The CMC has two RJ-45 Ethernet ports, labeled Gb1 (the uplink port) and STK/Gb2 (the stacking or cable
consolidation port). With basic cabling, you can connect the Gb port to the management network and
leave the STK/Gb2 port unused.
NOTE: The STK/Gb2 port can also be used for CMC NIC failover. Ensure that the CMC setting is
changed from default Stacking to Redundant to implement NIC failover.
CAUTION: Connecting the STK/Gb2 port to the management network will have unpredictable
results if the CMC setting is not changed from default Stacking to Redundant, to implement NIC
failover. In the default Stacking mode, cabling the Gb1 and STK/Gb2 ports to the same network
(broadcast domain) can cause a broadcast storm. A broadcast storm can also occur if the CMC
setting is changed to Redundant mode, but the cabling is daisy chained between chassis in the
Stacking mode. Ensure that the cabling model matches the CMC setting for the intended usage.
If you have multiple chassis in a rack, you can reduce the number of connections to the management
network by daisy-chaining up to four chassis together. This reduces the connections required from four
to one.
When daisy-chaining chassis together, Gb1 is the uplink port and STK/Gb2 is the stacking (cable
consolidation) port. Connect the Gb ports to the management network or to the STK port of the CMC in
a chassis that is closer to the network. You must connect the STK port only to a Gb port that is further
from the chain or network.
NOTE: The CMC must be installed for the system to power on. See the PowerEdge FX2/FX2s CMC
User’s Guide at dell.com/esmmanuals for complete instructions on setting up and operating the
CMC module.
17
Figure 12. CMC daisy-chaining
1. management network 2. CMC
Cooling fan indicator codes
Each cooling fan has an LED that indicates the power status of the cooling fan.
Indicator Pattern Condition
Not lit Cooling fan is functioning correctly.
Flashing Amber Indicates a problem with the cooling fan.
18
Figure 13. Cooling fan indicators
1. status indicator
Configuration wizard
The CMC is pre-configured to use a static IP address. To use Dynamic Host Configuration Protocol
(DHCP):
1. Access the Chassis Management Controller (CMC)
2. Click Network.
3. Click IPv4 or IPv6.
4. Select DHCP Enable.
For more information, see the Dell PowerEdge FX2 CMC User’s Guide at dell.com/esmmanuals.
System messages
The CMC web interface displays system messages to notify you of possible problems related to the
enclosure and to the sleds in the enclosure. For a detailed listing of these error messages, including
possible causes and solutions, see the Dell Event and Error Messages Reference Guide at dell.com/
esmmanuals.
19
Documentation matrix
The documentation matrix provides information about documents that you can refer to, for setting up
and managing your system.
To... Refer to...
Install your system into a rack Rack documentation included with your rack
solution
Set up your system and know the technical
specifications of your system
Getting Started Guide
Install the operating system Operating system documentation at dell.com/
operatingsystemmanuals
Get an overview of the Dell Systems Management
offerings
Dell OpenManage Systems Management Overview
Guide at dell.com/openmanagemanuals
Install, configure, and use the Chassis Management
Controller (CMC)
Dell PowerEdge FX2/FX2s CMC User’s Guide at
dell.com/esmmanuals
Know about the RACADM subcommands and
supported RACADM interfaces
RACADM Command Line Reference Guide for
iDRAC and CMC at dell.com/esmmanuals
Launch, enable and disable Lifecycle Controller,
know the features, use and troubleshoot Lifecycle
Controller
Dell Lifecycle Controller User’s Guide at dell.com/
esmmanuals
Use Lifecycle Controller Remote Services Dell Lifecycle Controller Remote Services Quick
Start Guide at dell.com/esmmanuals
Set up, use, and troubleshoot OpenManage Server
Administrator
Dell OpenManage Server Administrator User’s
Guide at dell.com/openmanagemanuals
Install, use and troubleshoot OpenManage
Essentials
Dell OpenManage Essentials User’s Guide at
dell.com/openmanagemanuals
Know the system features, remove and install
system components, and troubleshoot
components
Owner’s Manual at dell.com/poweredgemanuals
Know the compute sled features, remove and
install compute sled components, troubleshoot
compute sled components
Compute sled Owner’s Manual at dell.com/
poweredgemanuals
Know the storage sled features, storage sled to
compute sled configuration options, remove and
install storage sled components, and troubleshoot
components
Storage sled Owner’s Manual at dell.com/
poweredgemanuals
Configure and log in to iDRAC, set up managed
and management system, know the iDRAC
features and troubleshoot using iDRAC
Integrated Dell Remote Access Controller User's
Guide at dell.com/esmmanuals
Know about I/O module features, configure the
I/O module and additional I/O module information
I/O module documentation at dell.com/
poweredgemanuals
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95

Dell PowerEdge FX2 Owner's manual

Category
Network equipment chassis
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI