Herman Miller My Studio Environments Product Instructions

  • Hello! I'm a chat assistant who has read the installation instructions for the Herman Miller My Studio Environments 1B1JSS Power Harness. This document provides detailed information about the electrical ratings of the harness and the necessary steps for its proper and safe installation, including warnings about electrical safety. I'm here to answer your questions about this product.
  • What is the electrical rating of the power harness?
    What is the maximum number of receptacles a 20A circuit can supply?
    What is the maximum number of receptacles a 15A circuit can supply?
    What should you do before installation?
    What is important for electrical connections?
My Studio Environments
Power Harness
Installation
A1BLLF RLS FOR PROD MK JC
01-Apr-05
INSTRUCTIONS-
POWER HARNESS INSTALLATION
MAKE FROM 115160
PTL 19-Jan-10 JC -
JC - - -
13
1B1JSS
1B1JSS
REV PRODUCT NAME MK PG
21-Apr-06
1BSKRB
C1BTPXREV PART A & STEP 1 PIX MK JC
18-Aug-06
D 1CBNJ ADDED TEXT PTL JC
19-Jan-10
L
2009 Herman Miller, Inc., Zeeland, Michigan Printed in U.S.A.
L, Abak, Action Office, Avive, Co/Struc, Ethospace, Intersect, Meridian, Passage, Prospects, Quadrant, Resolve, Scooter, Vivo interiors, Lifework, Teneo,
and V-Wall are among the registered trademarks of Herman Miller Inc.
Burdick Group, CLT, Flex-Edge, My Studio Environments, and Q system, are among the trademarks of Herman Miller Inc.
Illustrations and specifications are based on the latest product information available at the time of publication. The right is reserved to make changes in design and specifications
at any time, without notice, and also to discontinue products.
©
®
1B1JSS REV D
My Studio Environments Power Harness Installation
Tools Required:
Power Driver #2 Phillips Bit
Electrical Harness
Screws (8)
Parts Included:
A
Hardware Pack
B
WARNING
!
Disconnect power before installation. Failure to do so can
cause electrical shock and personal injury.
WARNING
!
Electrically interconnected units must be mechanically
interconnected.
Electrical Rating:
120/208V, 120/240V 20A (15A CSA)
15A When Powered with Energy Manager (PT 130, PT 131)
1. A 20A rated circuit can supply a maximum of 13
receptacles at 15 A.
2. A 15A rated circuit can supply a maximum of 10
receptacles rated at 15A. Receptacles rated at
20A are not allowed.
1
1. Remove Center Wall Electrical Cladding.
2. Assemble Electrical Harness onto Center Wall Frame with (10) Screws.
Center Wall Frame
B
A
IMPORTANT: Save these instructions for layout changes.
L
2009 Herman Miller, Inc., Zeeland, Michigan Printed in U.S.A.
L, Abak, Action Office, Avive, Co/Struc, Ethospace, Intersect, Meridian, Passage, Prospects, Quadrant, Resolve, Scooter, Vivo interiors, Lifework, Teneo,
and V-Wall are among the registered trademarks of Herman Miller Inc.
Burdick Group, CLT, Flex-Edge, My Studio Environments, and Q system, are among the trademarks of Herman Miller Inc.
Illustrations and specifications are based on the latest product information available at the time of publication. The right is reserved to make changes in design and specifications
at any time, without notice, and also to discontinue products.
©
®
1B1JSS REV D
2
1. Connect Electrical Harnesses together.
Electrical Harness
Electrical Harness
WARNING
!
All electrical connections must be fully engaged and locked.
Loose connections can cause fire and /or electrical shock.
2. Make sure flexible end sections of Harnesses are formed into “S” shape before
installing cladding.