42-02-4P21 TABLE OF CONTENTS • v
5.4.4.15 Fully Manual Doors? ................................5-46
5.4.4.16 Cont. D.C.B. to Close Doors? .........................5-46
5.4.4.17 Cont. D.C.B. for Fire Ph 1? ...........................5-46
5.4.4.18 Moment. D.O.B. Door Opening ? .......................5-46
5.4.4.19 Doors to Open If Parked: ............................5-47
5.4.4.20 Doors to Open on Main Fire?..........................5-47
5.4.4.21 Doors to Open on Alt Fire? ...........................5-47
5.4.4.22 Leave Doors Open on CTL? ..........................5-47
5.4.4.23 Limited Door Re-open Option .........................5-47
5.4.4.24 Reduce HCT with Photo Eye ..........................5-47
5.4.4.26 Doors to Open If No Demand .........................5-47
5.4.4.27 Const. Press Op. Bypass PHE?........................5-47
5.4.4.28 Door Type Is Horizontal / Vertical ......................5-48
5.4.4.29 Front Door Cam Is Retiring / Fixed Type .................5-48
5.4.4.30 Rear Door Cam Is Retiring / Fixed Type .................5-48
5.4.4.31 Prevent DCP Til Doors Close?.........................5-48
5.4.4.32 Moment. D.C.B to Close Doors? .......................5-48
5.4.4.33 Doors to Latch DOF?................................5-48
5.4.4.34 Doors to Latch DCF?................................5-48
5.4.5 Timer Menu Options........................................5-48
5.4.5.1 Short Door Timer (Range: 0.5-16.0 Seconds) ..............5-48
5.4.5.2 Car Call Door Timer (Range: 0.5-16.0 Seconds) ............5-48
5.4.5.3 Hall Call Door Timer (Range: 0.5-16.0 Seconds) ............5-48
5.4.5.4 Lobby Door Timer (Range: 0.5-16.0 Seconds) .............5-48
5.4.5.5 Nudging Timer (Range: 10-60 Seconds) ..................5-49
5.4.5.6 Time out of Svce. Timer (Range: 15-120 Seconds or None) . . . 5-49
5.4.5.7 Motor Limit Timer (Range: 1.0 - 6.0 Minutes)...............5-49
5.4.5.8 Mgr Output Timer (Range: 0 - 27 Minutes) ................5-49
5.4.5.9 Door Hold Input Timer (Range: 0-120 Seconds) ............5-49
5.4.5.10 Parking Delay Timer (Range: 0.0-6.0 Minutes) ............5-49
5.4.5.11 Fan/light Output Timer (Range : 1.0-10.0 Minutes) .........5-49
5.4.5.12 Hospital Emerg. Timer (Range : 0.0-10.0 Minutes) .........5-49
5.4.5.13 Door Open Protection Timer (Range 8 - 30 Seconds) .......5-49
5.4.5.14 CTL Door Open Timer (Range: 2.0 - 60.0 Seconds) ........5-50
5.4.5.15 Door Buzzer Timer (Range: 0.0 - 30.0 Seconds) ...........5-50
5.4.6 Gongs/lanterns Menu Options ................................5-50
5.4.6.1 Mounted in Hall or Car? ...............................5-50
5.4.6.2 Double Strike on Down? ..............................5-50
5.4.6.3 PFG Enable Button? .................................5-50
5.4.6.4 Egress Floor Arrival Gong? ............................5-50
5.4.7 Spare Inputs Menu Options ..................................5-50
5.4.8 Spare Outputs Menu Options .................................5-53
5.4.9 Extra Features Menu Options.................................5-56
5.4.9.1 PI Output Type .....................................5-56
5.4.9.2 Floor Encoding Inputs? ...............................5-56
5.4.9.3 Encode All Floors?...................................5-56
5.4.9.4 Intermediate Speed? .................................5-56
5.4.9.5 Emergency Power Operation? / Emergency Power Return Floor 5-56
5.4.9.6 Light Load Weighing? / Light Load Car Call Limit ...........5-57
5.4.9.7 Photo Eye Anti-nuisance? / Consec Stops w/o PHE Limit .....5-57
5.4.9.8 Earthquake Operation ................................5-57
5.4.9.9 Counterweighted Drum Machine? .......................5-57
5.4.9.10 Mg Shutdown Operation? / MGS Return Floor.............5-58
5.4.9.11 Peripheral Device?..................................5-58
5.4.9.12 Automatic Floor Stop Option? .........................5-58