Krone Messages - Parameters Operating instructions

Type
Operating instructions
Enclose this document with the operating instructions of the
machine.
Supplement to operating
instructions
Document number: 150001737_02_us
Version: 14/08/2023
Bale accumulator
Software version: D2515020094000008
Table of contents
2
Bale accumulator
Supplement to operating instructions 150001737_02_en
1 Information on this document ..................................................................................................3
1.1 Validity .........................................................................................................................................3
1.2 Re-ordering ..................................................................................................................................3
1.3 Applicable documents..................................................................................................................3
2 Safety ..........................................................................................................................................4
2.1 Meaning of the supplement to the operating instructions ............................................................4
3 Error messages..........................................................................................................................5
3.1 Possible error types (FMI)............................................................................................................6
3.2 Error list........................................................................................................................................6
Index..........................................................................................................................................19
Information on this document 1
Validity 1.1
Bale accumulator
Supplement to operating instructions 150001737_02_en 3
1 Information on this document
1.1 Validity
This document is valid for:
Ballensammelwagen
1.2 Re-ordering
You can request a replacement document if this document became completely or partly
unusable, or if you need it in a different language. Please specify the document number shown
on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.mykrone.green.
1.3 Applicable documents
To ensure that the machine is used safely and as intended, observe the following further
applicable documents.
Operating instructions of the respective machine
2 Safety
2.1 Meaning of the supplement to the operating instructions
4
Bale accumulator
Supplement to operating instructions 150001737_02_en
2 Safety
WARNING
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions
must be read and observed.
WARNING
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read
and observed.
INFO
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating
instructions.
2.1 Meaning of the supplement to the operating instructions
The supplement to the operating instructions is an important document and a part of the
machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured
or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time,see Page3.
Before working, also read and observe the respective sections of the corresponding
operating instructions,see Page3.
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
Error messages 3
Bale accumulator
Supplement to operating instructions 150001737_02_en 5
3 Error messages
WARNING
Risk of injury to persons and damage to machines if error messages are ignored
If error messages are ignored and the fault is not rectified, there is a risk of injury to persons
and/or severe damage to the machine.
Eliminate the disturbance when an error message is displayed, see Page6.
If the fault cannot be rectified, contact KRONE service partner.
CAN1
KMC - 520192- 19
EQG000-034
The display shows an error message when a disturbance occurs on the machine. At the same
time, an audible signal sounds (continuous horn signal). For a list of the error messages, see
Page6.
Configuration of an error message
The error message is configured according to the following sample: e.g. error message
"520192-19
CAN1
"
520192 19
CAN1
SPN (Suspect Parameter
Number) = error number
FMI = type of error, see
Page6
Icon
Acknowledging error message
Note down the error message.
Briefly press on .
ÆThe acoustic signal stops and the error display is no longer indicated. The error message is
displayed again if the fault occurs again.
Rectify the error, see Page6.
Acknowledged and still pending error messages can be displayed again via the "Error list" menu
or the status line.
3 Error messages
3.1 Possible error types (FMI)
6
Bale accumulator
Supplement to operating instructions 150001737_02_en
3.1 Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI Meaning
0 The upper limit value was greatly exceeded.
1 The lower limit value was far below the required one.
2 The data is not permitted.
3 There is an overvoltage or a short circuit to supply voltage.
4 There is an undervoltage or a short circuit to ground.
5 A cable is broken or amperage is too low.
6 There is a short circuit to ground or amperage is too low.
7 The mechanics do not respond or the expected result was not achieved.
8 The frequency is not permitted.
9 There is an abnormal update rate.
10 There is an abnormal rate of change.
11 The error cause is unknown.
12 There is an internal error.
13 The values of the calibration are outside the value range.
14 Particular instructions are required.
15 The upper limit value has been reached.
16 The upper limit value has been exceeded.
17 The lower limit value has been reached.
18 The lower limit value has not been reached.
19 There is a CAN communication failure.
20 The data deviates upwards.
21 The data deviates downwards.
31 The condition has been fulfilled.
3.2 Error list
Overview of the control units
Abbreviation Explanation
>>>
2en_Fehlerliste [}7]
Error list
Software version: D2515020094000008_100,
D2515020140900008_100
Control unit: KMC
Page 1
Error number Error text Description Figure
KMC-520192-19 CAN 1 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 1.
KMC-520193-19 CAN 2 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 2.
KMC-520194-19 CAN 3 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 3.
KMC-520195-19 CAN 4 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 4.
KMC-520198-12 Control unit - Internal Error An internal error in the control unit
which was actuated by defective
software or hardware.
KMC-520232-12 Vehicle identification number -
Internal Error
Vehicle identification number has not
been initialised.
KMC-520234-31 System check with KMC failed With the KMC the cross-controller
adjustment of system-relevant
machine data has failed.
KMC-521100-3 Voltage group UB1 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521100-4 Voltage group UB1 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521100-5 Voltage group UB1 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521100-6 Voltage group UB1 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521101-3 Voltage group UB2 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521101-4 Voltage group UB2 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521101-5 Voltage group UB2 - Ground fault The maximum load on the supply
voltage has been exceeded.
KMC-521101-6 Voltage group UB2 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521102-3 Voltage group UB3 - Overvoltage The input voltage of the corresponding
voltage group is too high.
Page 2
Error number Error text Description Figure
KMC-521102-4 Voltage group UB3 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521102-5 Voltage group UB3 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521102-6 Voltage group UB3 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521103-3 Voltage group UB4 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521103-4 Voltage group UB4 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521103-5 Voltage group UB4 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521103-6 Voltage group UB4 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521104-3 Voltage group UB5 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521104-4 Voltage group UB5 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521104-5 Voltage group UB5 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521104-6 Voltage group UB5 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521105-3 Voltage group UB6 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521105-4 Voltage group UB6 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521105-5 Voltage group UB6 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521105-6 Voltage group UB6 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521106-11 Supply voltage sensors - General
disturbance
The voltage has been switched off due
to an overload or a short circuit on the
supply voltage of the sensors.
Page 3
Error number Error text Description Figure
KMC-521107-3 Supply voltage - Overvoltage The power supply on the UE
connection is too high.
KMC-521107-4 Supply voltage - Undervoltage The power supply on the UE
connection is too low.
KMC-521108-11 Control unit - General disturbance The voltage group relay UB1 has not
passed the self-test.
KMC-521109-11 Control unit - General disturbance The voltage group relay UB2 has not
passed the self-test.
KMC-521110-11 Control unit - General disturbance The voltage group relay UB3 has not
passed the self-test.
KMC-521111-11 Control unit - General disturbance The voltage group relay UB4 has not
passed the self-test.
KMC-521112-11 Control unit - General disturbance The voltage group relay UB5 has not
passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not
passed the self-test.
KMC-521114-11 Sensor supply voltage Uext1 -
General disturbance
The voltage group Uext1 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521115-11 Sensor supply voltage Uext2 -
General disturbance
The voltage group Uext2 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521116-11 Sensor supply voltage Uext3 -
General disturbance
The voltage group Uext3 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521117-11 Sensor supply voltage Uext4 -
General disturbance
The voltage group Uext4 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521320-2 Machine configuration - Logic error
electronics
Configuration of the machine is not
compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
KMC-521351-11 Control unit - General disturbance
KMC-522001-7 Lateral platform on left - Logic fault
mechanics
The bale accumulator is in field mode
and the lateral platform on left is not
completely folded out.
Page 4
Error number Error text Description Figure
KMC-522002-7 Lateral platform on left - Logic fault
mechanics
The bale accumulator is in road mode
and the lateral platform on left has not
been completely folded in.
KMC-522003-16 Time error lateral platform on left -
Upper limit value exceeded
The lateral platform on left has not
been completely folded in within a
defined time.
KMC-522004-16 Time error lateral platform on left -
Upper limit value exceeded
The lateral platform on left has not
been completely folded out within a
defined time.
KMC-522005-7 Lateral platform on right - Logic fault
mechanics
The bale accumulator is in field mode
and the lateral platform on right is not
completely folded out.
KMC-522006-7 Lateral platform on right - Logic fault
mechanics
The bale accumulator is in road mode
and the lateral platform on right has
not been completely folded in.
KMC-522007-16 Time error lateral platform on right -
Upper limit value exceeded
The lateral platform on right has not
been completely folded in within a
defined time.
KMC-522008-16 Time error lateral platform on right -
Upper limit value exceeded
The lateral platform on right has not
been completely folded out within a
defined time.
KMC-522010-16 Time error move side shift bar to right
- Upper limit value exceeded
The side shift bar has not completely
moved to the right into the end position
within a defined time.
KMC-522011-16 Time error move side shift bar to left -
Upper limit value exceeded
The side shift bar has not completely
moved to the left into the end position
within a defined time.
KMC-522013-16 Time error move ejector forwards -
Upper limit value exceeded
The ejector has not completely moved
to the front within a defined time.
KMC-522014-16 Time error move ejector backwards -
Upper limit value exceeded
The ejector has not completely moved
to the rear within a defined time.
KMC-522016-7 Drawbar - Logic fault mechanics The drawbar has not been completely
extended in road mode.
KMC-522017-16 Time error retract drawbar - Upper
limit value exceeded
The drawbar has not been completely
retracted within a defined time.
KMC-522018-16 Time error extend drawbar - Upper
limit value exceeded
The drawbar has not been completely
extended within a defined time.
KMC-522020-7 Switch/momentary switch S1
Retracting drawbar - Key pressed
when system starts
The momentary switch S1 "Retract
drawbar" is sticking.
KMC-522021-7 Self-steering on left - Logic fault
mechanics
Self-steering on left has not been
locked in road mode.
Page 5
Error number Error text Description Figure
KMC-522022-7 Self-steering on left - Logic fault
mechanics
Self-steering on left has not been
released in field mode.
KMC-522023-16 Time error release self-steering on
left - Upper limit value exceeded
Self-steering on left has not been
completely released within a defined
time.
KMC-522024-16 Time error lock self-steering on left -
Upper limit value exceeded
The pendulum wheel on left has not
been completely locked within a
defined time.
KMC-522025-7 Self-steering on right - Logic fault
mechanics
Self-steering on right has not been
locked in road mode.
KMC-522026-7 Self-steering on right - Logic fault
mechanics
Self-steering on right has not been
released in field mode.
KMC-522027-16 Time error release self-steering on
right - Upper limit value exceeded
Self-steering on right has not been
completely released within a defined
time.
KMC-522028-16 Time error lock self-steering on right -
Upper limit value exceeded
Self-steering on right has not been
completely locked within a defined
time.
KMC-522029-7 Bale sensor at front - Logic fault
mechanics
Sensor B90 "Bale sensor at front" is
still attenuated.
KMC-522030-7 Rear bale sensor - Logic fault
mechanics
Sensor B95 "Bale sensor at rear" is
still attenuated.
KMC-522031-2 Automatic mode terminated - Logic
error electronics
Automatic mode was automatically
terminated due to a fault.
KMC-522032-2 Drawbar - Logic error electronics Sensor B89 "Retract drawbar" is not
attenuated even through the sensor
B88 "Extend drawbar" is already
attenuated.
KMC-522033-2 Self-steering on right - Logic error
electronics
The sensors B92 "Self-steering on
right locked" and B94 "Self-steering on
right released" do not deliver any
plausible values for the end position of
self-steering on right. Both sensors are
attenuated.
KMC-522034-2 Self-steering on left - Logic error
electronics
The sensors B91 "Self-steering on left
locked" and B93 "Self-steering on left
released" do not deliver any plausible
values for the end position of self-
steering on left. Both sensors are
attenuated.
KMC-522035-2 Lateral platform on right - Logic error
electronics
The sensors B86 "Lateral platform on
right folded in" and B87 "Lateral
platform on right folded out" do not
deliver any plausible values for the end
position of the lateral platform on right.
Both sensors are attenuated.
Page 6
Error number Error text Description Figure
KMC-522036-2 Lateral platform on left - Logic error
electronics
The sensors B84 "Lateral platform on
left folded in" and B85 "Lateral platform
on left folded out" do not deliver any
plausible values for the end position of
the lateral platform on left. Both
sensors are attenuated.
KMC-522037-2 Machine in working position - Logic
error electronics
The machine is in field mode and is
not prepared for road mode.
KMC-522101-3 Sensor B80 Ejector end position at
front - Cable break
KMC-522101-4 Sensor B80 Ejector end position at
front - Short circuit to ground or UB
KMC-522102-3 Sensor B81 Ejector end position at
rear - Cable break
KMC-522102-4 Sensor B81 Ejector end position at
rear - Short circuit to ground or UB
KMC-522103-3 Sensor B82 Side shift bar end
position on right - Cable break
KMC-522103-4 Sensor B82 Side shift bar end
position on right - Short circuit to
ground or UB
KMC-522104-3 Sensor B83 Side shift bar end
position on left - Cable break
KMC-522104-4 Sensor B83 Side shift bar end
position on left - Short circuit to
ground or UB
KMC-522105-3 Sensor B84 Lateral platform on left
folded in - Cable break
KMC-522105-4 Sensor B84 Lateral platform on left
folded in - Short circuit to ground or
UB
KMC-522106-3 Sensor B85 Lateral platform left
folded out - Cable break
KMC-522106-4 Sensor B85 Lateral platform left
folded out - Short circuit to ground or
UB
KMC-522107-3 Sensor B86 Lateral platform on right
folded in - Cable break
KMC-522107-4 Sensor B86 Lateral platform on right
folded in - Short circuit to ground or
UB
Page 7
Error number Error text Description Figure
KMC-522108-3 Sensor B87 Lateral platform on right
folded out - Cable break
KMC-522108-4 Sensor B87 Lateral platform on right
folded out - Short circuit to ground or
UB
KMC-522109-3 Sensor B88 Drawbar extended -
Cable break
KMC-522109-4 Sensor B88 Drawbar extended -
Short circuit to ground or UB
KMC-522110-3 Sensor B89 Drawbar retracted -
Cable break
KMC-522110-4 Sensor B89 Drawbar retracted -
Short circuit to ground or UB
KMC-522111-3 Sensor B90 Bale sensor at front -
Cable break
KMC-522111-4 Sensor B90 Bale sensor at front -
Short circuit to ground or UB
KMC-522112-3 Sensor B91 Self-steering on left
locked - Cable break
KMC-522112-4 Sensor B91 Self-steering on left
locked - Short circuit to ground or UB
KMC-522113-3 Sensor B92 Self-steering on right
locked - Cable break
KMC-522113-4 Sensor B92 Self-steering on right
locked - Short circuit to ground or UB
KMC-522114-3 Sensor B93 Self-steering on left
released - Cable break
KMC-522114-4 Sensor B93 Self-steering on left
released - Short circuit to ground or
UB
KMC-522115-3 Sensor B94 Self-steering on right
released - Cable break
KMC-522115-4 Sensor B94 Self-steering on right
released - Short circuit to ground or
UB
Page 8
Error number Error text Description Figure
KMC-522116-3 Switch/momentary switch S1
Retracting drawbar - Cable break
KMC-522116-4 Switch/momentary switch S1
Retracting drawbar - Short circuit to
ground or UB
KMC-522117-3 Sensor B95 Rear bale sensor - Cable
break
KMC-522117-4 Sensor B95 Rear bale sensor - Short
circuit to ground or UB
KMC-522140-16 Sensor
- B97 Force sensor front left
- B98 Force sensor front right
- Upper limit value exceeded
KMC-522140-18 Sensor
- B97 Force sensor front left
- B98 Force sensor front right
- Lower limit value below minimum
KMC-522141-16 Sensor
- B99 Force sensor rear left
- B100 Force sensor rear right
- Upper limit value exceeded
KMC-522141-18 Sensor
- B99 Force sensor rear left
- B100 Force sensor rear right
- Lower limit value below minimum
KMC-522144-3 Sensor B96 acceleration sensor -
Cable break
KMC-522144-4 Sensor B96 acceleration sensor -
Short circuit to ground or UB
KMC-522301-3 Valve K81 Pilot valve 1 - Cable break
or short circuit to UB
KMC-522301-6 Valve K81 Pilot valve 1 - Short circuit
to ground
KMC-522302-3 Valve K82 Pilot valve 2 - Cable break
or short circuit to UB
KMC-522302-6 Valve K82 Pilot valve 2 - Short circuit
to ground
KMC-522303-3 Valve K83 Move ejector backwards 1
- Cable break or short circuit to UB
KMC-522303-6 Valve K83 Move ejector backwards 1
- Short circuit to ground
Page 9
Error number Error text Description Figure
KMC-522304-3 Valve K84 Move ejector forwards 1 -
Cable break or short circuit to UB
KMC-522304-6 Valve K84 Move ejector forwards 1 -
Short circuit to ground
KMC-522305-3 Valve K85 Move side shift bar to left 1
- Cable break or short circuit to UB
KMC-522305-6 Valve K85 Move side shift bar to left 1
- Short circuit to ground
KMC-522306-3 Valve K86 Move side shift bar to right
1 - Cable break or short circuit to UB
KMC-522306-6 Valve K86 Move side shift bar to right
1 - Short circuit to ground
KMC-522307-3 Valve K87 Load Sensing active -
Cable break or short circuit to UB
KMC-522307-6 Valve K87 Load Sensing active -
Short circuit to ground
KMC-522308-3 Valve K88 Retracting drawbar - Cable
break or short circuit to UB
KMC-522308-6 Valve K88 Retracting drawbar - Short
circuit to ground
KMC-522309-3 Valve K89 Extend drawbar - Cable
break or short circuit to UB
KMC-522309-6 Valve K89 Extend drawbar - Short
circuit to ground
KMC-522310-3 Valve K90 Fold in lateral platforms -
Cable break or short circuit to UB
KMC-522310-6 Valve K90 Fold in lateral platforms -
Short circuit to ground
KMC-522311-3 Sensor B91 Self-steering on left
locked - Cable break or short circuit
to UB
KMC-522311-6 Valve K91 Fold out lateral platforms -
Short circuit to ground
Page 10
Error number Error text Description Figure
KMC-522312-3 Valve K92 Lock self-steering - Cable
break or short circuit to UB
KMC-522312-6 Sensor B92 Self-steering on right
locked - Short circuit to ground
KMC-522313-3 Sensor B93 Self-steering on left
released - Cable break or short
circuit to UB
KMC-522313-6 Sensor B93 Self-steering on left
released - Short circuit to ground
KMC-522315-3 Valve K94 Move ejector backwards 2
- Cable break or short circuit to UB
KMC-522315-6 Sensor B94 Self-steering on right
released - Short circuit to ground
KMC-522316-3 Valve K95 Move ejector forwards 2 -
Cable break or short circuit to UB
KMC-522316-6 Sensor B95 Rear bale sensor - Short
circuit to ground
KMC-522317-3 Valve K96 Move side shift bar to left 2
- Cable break or short circuit to UB
KMC-522317-6 Valve K96 Move side shift bar to left 2
- Short circuit to ground
KMC-522318-3 Valve K97 Move side shift bar to right
2 - Cable break or short circuit to UB
KMC-522318-6 Valve K97 Move side shift bar to right
2 - Short circuit to ground
KMC-522506-11 TECU - General disturbance
KMC-522510-19 ISB - Malfunction
KMC-522511-12 ISB - Internal Error
KMC-522560-19 FMA1 - Malfunction
Page 11
Error number Error text Description Figure
KMC-522561-4 FMA1 - Undervoltage FMA 1 undervoltage
KMC-522562-12 FMA1 - Internal Error
Index
Bale accumulator
Supplement to operating instructions 150001737_02_en 19
A
Acknowledging error message ............................. 5
Applicable documents .......................................... 3
E
Error list ................................................................ 6
Error messages .................................................... 5
I
Information on this document ............................... 3
M
Meaning of the supplement to the operating
instructions ........................................................... 4
P
Possible error types (FMI) .................................... 6
R
Re-ordering .......................................................... 3
S
Safety ................................................................... 4
V
Validity.................................................................. 3
Maschinenfabrik
Bernard Krone GmbH & Co. KG
*Heinrich-Krone-Straße 10
D-48480 Spelle
*Postfach 11 63
D-48478 Spelle
'+49 (0) 59 77 / 935-0
6+49 (0) 59 77 / 935-339
üwww.landmaschinen.krone.de
V.3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Krone Messages - Parameters Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI