Bale wrapper
Software version: D2515020139100002
Error messages
Table of contents
2
Bale wrapper
Supplement to operating instructions 150001621_01_en
1 Information on this document ..................................................................................................3
1.1 Validity .........................................................................................................................................3
1.2 Re-ordering ..................................................................................................................................3
1.3 Applicable documents..................................................................................................................3
2 Safety ..........................................................................................................................................4
2.1 Meaning of the supplement to the operating instructions ............................................................4
3 Error messages..........................................................................................................................5
3.1 Possible error types (FMI)............................................................................................................6
3.2 Error list........................................................................................................................................6
4 Index..........................................................................................................................................20
Information on this document 1
Validity 1.1
Bale wrapper
Supplement to operating instructions 150001621_01_en 3
1 Information on this document
1.1 Validity
This document is valid for:
BW301-20 (EasyWrap 165 T)
1.2 Re-ordering
You can request a replacement document if this document became completely or partly
unusable, or if you need it in a different language. Please specify the document number shown
on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.mykrone.green.
1.3 Applicable documents
To ensure that the machine is used safely and as intended, observe the following further
applicable documents.
Operating instructions of the respective machine
2 Safety
2.1 Meaning of the supplement to the operating instructions
4
Bale wrapper
Supplement to operating instructions 150001621_01_en
2 Safety
WARNING
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions
must be read and observed.
WARNING
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read
and observed.
INFO
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating
instructions.
2.1 Meaning of the supplement to the operating instructions
The supplement to the operating instructions is an important document and a part of the
machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured
or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time,see Page3.
Before working, also read and observe the respective sections of the corresponding
operating instructions,see Page3.
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
Error messages 3
Bale wrapper
Supplement to operating instructions 150001621_01_en 5
3 Error messages
WARNING
Risk of injury to persons and damage to machines if error messages are ignored
If error messages are ignored and the fault is not rectified, there is a risk of injury to persons
and/or severe damage to the machine.
Eliminate the disturbance when an error message is displayed, see Page6.
If the fault cannot be rectified, contact KRONE service partner.
CAN1
KMC - 520192- 19
EQG000-034
The display shows an error message when a disturbance occurs on the machine. At the same
time, an audible signal sounds (continuous horn signal). For a list of the error messages, see
Page6.
Configuration of an error message
The error message is configured according to the following sample: e.g. error message
"520192-19
CAN1
"
520192 19
CAN1
SPN (Suspect Parameter
Number) = error number
FMI = type of error, see
Page6
Icon
Acknowledging error message
Note down the error message.
Briefly press on .
ÆThe acoustic signal stops and the error display is no longer indicated. The error message is
displayed again if the fault occurs again.
Rectify the error, see Page6.
Acknowledged and still pending error messages can be displayed again via the "Error list" menu
or the status line.
3 Error messages
3.1 Possible error types (FMI)
6
Bale wrapper
Supplement to operating instructions 150001621_01_en
3.1 Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI Meaning
0 The upper limit value was greatly exceeded.
1 The lower limit value was far below the required one.
2 The data is not permitted.
3 There is an overvoltage or a short circuit to supply voltage.
4 There is an undervoltage or a short circuit to ground.
5 A cable is broken or amperage is too low.
6 There is a short circuit to ground or amperage is too low.
7 The mechanics do not respond or the expected result was not achieved.
8 The frequency is not permitted.
9 There is an abnormal update rate.
10 There is an abnormal rate of change.
11 The error cause is unknown.
12 There is an internal error.
13 The values of the calibration are outside the value range.
14 Particular instructions are required.
15 The upper limit value has been reached.
16 The upper limit value has been exceeded.
17 The lower limit value has been reached.
18 The lower limit value has not been reached.
19 There is a CAN communication failure.
20 The data deviates upwards.
21 The data deviates downwards.
31 The condition has been fulfilled.
3.2 Error list
Overview of the control units
Abbreviation Explanation
KMC KRONE Machine Controller
>>>
2D2515020139100002_en-gb [}7]
Error list
Software version: D2515020143000002_300,
D2515020139300002_300
Control unit: KMC
Page 1
Error number Error text Description Figure
KMC-520192-19 CAN 1 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 1.
KMC-520193-19 CAN 2 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 2.
KMC-520194-19 CAN 3 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 3.
KMC-520195-19 CAN 4 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 4.
KMC-520198-12 Control unit - Internal Error An internal error in the control unit
which was actuated by defective
software or hardware.
KMC-520232-12 Vehicle identification number -
Internal Error
Vehicle identification number has not
been initialised.
KMC-520234-31 System check with KMC failed With the KMC the cross-controller
adjustment of system-relevant
machine data has failed.
KMC-521100-3 Voltage group UB1 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521100-4 Voltage group UB1 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521100-5 Voltage group UB1 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521100-6 Voltage group UB1 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521101-3 Voltage group UB2 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521101-4 Voltage group UB2 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521101-5 Voltage group UB2 - Ground fault The maximum load on the supply
voltage has been exceeded.
KMC-521101-6 Voltage group UB2 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521102-3 Voltage group UB3 - Overvoltage The input voltage of the corresponding
voltage group is too high.
Page 2
Error number Error text Description Figure
KMC-521102-4 Voltage group UB3 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521102-5 Voltage group UB3 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521102-6 Voltage group UB3 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521103-3 Voltage group UB4 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521103-4 Voltage group UB4 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521103-5 Voltage group UB4 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521103-6 Voltage group UB4 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521104-3 Voltage group UB5 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521104-4 Voltage group UB5 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521104-5 Voltage group UB5 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521104-6 Voltage group UB5 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521105-3 Voltage group UB6 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521105-4 Voltage group UB6 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521105-5 Voltage group UB6 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521105-6 Voltage group UB6 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521106-11 Supply voltage sensors - General
disturbance
The voltage has been switched off due
to an overload or a short circuit on the
supply voltage of the sensors.
Page 3
Error number Error text Description Figure
KMC-521107-3 Supply voltage - Overvoltage The power supply on the UE
connection is too high.
KMC-521107-4 Supply voltage - Undervoltage The power supply on the UE
connection is too low.
KMC-521108-11 Control unit - General disturbance The voltage group relay UB1 has not
passed the self-test.
KMC-521109-11 Control unit - General disturbance The voltage group relay UB2 has not
passed the self-test.
KMC-521110-11 Control unit - General disturbance The voltage group relay UB3 has not
passed the self-test.
KMC-521111-11 Control unit - General disturbance The voltage group relay UB4 has not
passed the self-test.
KMC-521112-11 Control unit - General disturbance The voltage group relay UB5 has not
passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not
passed the self-test.
KMC-521114-11 Sensor supply voltage Uext1 -
General disturbance
The voltage group Uext1 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521115-11 Sensor supply voltage Uext2 -
General disturbance
The voltage group Uext2 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521116-11 Sensor supply voltage Uext3 -
General disturbance
The voltage group Uext3 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521117-11 Sensor supply voltage Uext4 -
General disturbance
The voltage group Uext4 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521320-2 Machine configuration - Logic error
electronics
Configuration of the machine is not
compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
KMC-521351-11 Control unit - General disturbance
KMC-520198-12 Internal Error Internal error in the control unit caused
by defective software or hardware.
Page 4
Error number Error text Description Figure
KMC-522002-7 Logic fault mechanics Automatic function timeout. The target
position could not be reached.
KMC-522003-7 Logic fault mechanics Stuck key quick stop
KMC-522004-7 Logic fault mechanics Stuck key wrapping arm safety
bracket
KMC-522005-7 Logic fault mechanics Quick stop triggered
KMC-522006-7 Logic fault mechanics Wrapping arm safety bracket triggered
KMC-522008-7 Logic fault mechanics Bale on table in road mode
KMC-522009-7 Logic fault mechanics Film tear detected on one side
KMC-522010-7 Logic fault mechanics Film tear detected on two sides
KMC-522011-7 Logic fault mechanics The current rotational speed of the
wrapping arm deviates from the default.
KMC-522012-7 Logic fault mechanics The current rotational speed of the
wrapping table deviates from the
default.
KMC-522013-7 Switch/momentary switch S4
Release button - lift/right/reverse/turn
- Logic fault mechanics
Stuck key release button for lift/right/
forward
KMC-522014-7 Logic fault mechanics Stuck key release button lower/left/
reverse
KMC-522021-7 Logic fault mechanics No bale detected
KMC-522022-7 Logic fault mechanics Bale on table
KMC-522023-7 Logic fault mechanics Holding and cutting device not closed
KMC-522024-7 Position of bale turner - Logic fault
mechanics
The position of the bale turner does not
correspond to the target position
Page 5
Error number Error text Description Figure
KMC-522025-7 Drawbar position - Logic fault
mechanics
The position of the drawbar does not
correspond to the target position
KMC-522026-7 Holding and cutting device position -
Logic fault mechanics
The position of the holding and cutting
device does not correspond to the
target position
KMC-522027-7 Lifting arm position - Logic fault
mechanics
The position of the lifting arm does not
correspond to the target position
KMC-522028-7 Holder bracket position - Logic fault
mechanics
The position of the holder bracket does
not correspond to the target position
KMC-522029-7 Position wrapping arm - Logic fault
mechanics
The position of the wrapping arm does
not correspond to the target position
KMC-522030-7 Position of wrapping table - Logic
fault mechanics
The position of the wrapping table does
not correspond to the target position
KMC-522031-7 Safety check for road mode 1 - Logic
fault mechanics
The safety check for road mode 1
failed.
KMC-522032-7 Safety check for road mode 2 Valve
Q10 Speed drawbar - Logic fault
mechanics
The safety check for road mode 2
failed
KMC-522033-7 Safety check for field mode 1 Valve
Q10 Speed drawbar - Logic fault
mechanics
The safety check for field mode 1
failed.
KMC-522034-7 Drawbar not in transport position -
Logic fault mechanics
The drawbar is not in transport position
during road mode.
KMC-522035-7 Plausibility of wheel sensors Sensor
- B16 Wheel speed on left
- B21 Wheel speed on right
- Logic fault mechanics
The speeds of the wheel sensors are
not plausible in combination
KMC-522036-7 Rotational speed deviation wrapping
arm - Logic fault mechanics
The speed of the wrapping arm
deviates from the default.
KMC-522037-7 Wrapping arm valve fault Valve Q2
Drive of wrapping arm - Logic fault
mechanics
The wrapping arm speed valve does
not close correctly.
KMC-522038-7 Valve error holding and cutting device
left Valve Q14 Move holding and
cutting device on left - Logic fault
mechanics
The "Move holding and cutting device
left" valve does not close correctly.
KMC-522039-7 Valve error holding and cutting device
right Valve Q15 Move right holding
and cutting device - Logic fault
mechanics
The "Move holding and cutting device
right" valve does not close correctly.
KMC-522040-7 Valve error holder bracket Valve Q7
Move lifting unit - Logic fault
mechanics
The "Lifting unit" valve does not close
correctly.
Page 6
Error number Error text Description Figure
KMC-522041-7 Valve error wrapping table Valve Q16
Move wrapping table - Logic fault
mechanics
The "Move wrapping table" valve does
not close correctly.
KMC-522042-7 Valve error bale turner Valve Q17
Move bale turner - Logic fault
mechanics
The "Move bale turner" valve does not
close correctly.
KMC-522043-7 Valve error drawbar Valve Q10 Speed
drawbar - Logic fault mechanics
The "Drawbar speed" valve does not
close correctly.
KMC-522044-7 Setting down timeout - Logic fault
mechanics
The bale could not be set down in the
assigned time.
KMC-522045-7 Valve error lifting arm Valve Q8 Move
lifting arm - Logic fault mechanics
The "Move lifting arm" valve does not
close correctly.
KMC-522046-2 Contact fault slip ring - Logic error
electronics
The signals of the slip ring transmitter
do not logically match.
KMC-522101-3 Sensor A70.B240 Position wrapping
arm - Short circuit to UB
The "Wrapping arm position" sensor is
reporting a short circuit
KMC-522101-4 Sensor A70.B240 Position wrapping
arm - Cable break or short circuit to
ground
The "Wrapping arm position" sensor is
reporting a cable break
KMC-522102-3 Sensor B2 Bale in pick-up position -
Cable break
The "Bale in pick-up position" sensor
is reporting a cable break
KMC-522102-4 Sensor B2 Bale in pick-up position -
Short circuit to ground or UB
The "Bale in pick-up position" sensor
is reporting a short circuit
KMC-522104-3 Sensor B4 Holding and cutting device
on left closed - Cable break
The "Holding and cutting device left
closed" sensor is reporting a cable
break
KMC-522104-4 Sensor B4 Holding and cutting device
on left closed - Short circuit to
ground or UB
The "Holding and cutting device left
closed" sensor is reporting a short
circuit
KMC-522106-3 Sensor B6 Holding and cutting device
on right closed - Cable break
The "Holding and cutting device right
closed" sensor is reporting a cable
break
KMC-522106-4 Sensor B6 Holding and cutting device
on right closed - Short circuit to
ground or UB
The "Holding and cutting device right
closed" sensor is reporting a short
circuit
KMC-522107-3 Sensor A70.B225 Film tear detection
1 - Cable break
The "Film tear detection 1" sensor is
reporting a cable break
KMC-522107-4 Sensor A70.B225 Film tear detection
1 - Short circuit to ground or UB
The "Film tear detection 1" sensor is
reporting a short circuit
Page 7
Error number Error text Description Figure
KMC-522108-3 Sensor A70.B226 Film tear detection
2 - Cable break
The "Film tear detection 2" sensor is
reporting a cable break
KMC-522108-4 Sensor A70.B226 Film tear detection
2 - Short circuit to ground or UB
The "Film tear detection 2" sensor is
reporting a short circuit
KMC-522109-3 Sensor B9 Bale detection wrapping
table - Cable break
The "Bale on table" sensor is reporting
a cable break
KMC-522109-4 Sensor B9 Bale detection wrapping
table - Short circuit to ground or UB
The "Bale on table" sensor is reporting
a short circuit
KMC-522110-3 Sensor B10 Position of wrapping
table - Short circuit to UB
The "Wrapping table position" sensor
is reporting a short circuit
KMC-522110-4 Sensor B10 Position of wrapping
table - Cable break or short circuit to
ground
The "Wrapping table position" sensor
is reporting a cable break
KMC-522111-3 Sensor B11 Speed of wrapping table
- Cable break
The "Speed of wrapping table" sensor
is reporting a cable break
KMC-522111-4 Sensor B11 Speed of wrapping table
- Short circuit to ground or UB
The "Speed of wrapping table" sensor
is reporting a short circuit
KMC-522112-3 Sensor B12 Position of lifting unit -
Short circuit to UB
The "Holder bracket position" sensor is
reporting a short circuit
KMC-522112-4 Sensor B12 Position of lifting unit -
Cable break or short circuit to ground
The "Holder bracket position" sensor is
reporting a cable break
KMC-522112-6 Valve Q12 Pilot valve speed 2 - Short
circuit to ground
The "Pilot valve speed 2" actuator is
reporting a short circuit
KMC-522113-3 Sensor B13 Lifting arm closed -
Cable break
The "Lifting arm closed" sensor is
reporting a cable break
KMC-522113-4 Sensor B13 Lifting arm closed -
Short circuit to ground or UB
The "Lifting arm closed" sensor is
reporting a short circuit
KMC-522116-3 Sensor B16 Wheel speed on left -
Cable break
The "Wheel speed left" sensor is
reporting a cable break
KMC-522116-4 Sensor B16 Wheel speed on left -
Short circuit to ground or UB
The "Wheel speed left" sensor is
reporting a short circuit
KMC-522118-3 Sensor B19 Bale turner folded in -
Cable break
The "Bale turner folded in" sensor is
reporting a cable break
Page 8
Error number Error text Description Figure
KMC-522118-4 Sensor B19 Bale turner folded in -
Short circuit to ground or UB
The "Bale turner folded in" sensor is
reporting a short circuit
KMC-522120-3 Sensor B20 Working angle of
articulated drawbar - Short circuit to
UB
The "Articulated drawbar working
angle" sensor is reporting a short
circuit
KMC-522120-4 Sensor B20 Working angle of
articulated drawbar - Cable break or
short circuit to ground
The "Articulated drawbar working
angle" sensor is reporting a cable
break
KMC-522121-3 Sensor B21 Wheel speed on right -
Cable break
The "Wheel speed right" sensor is
reporting a cable break
KMC-522121-4 Sensor B21 Wheel speed on right -
Short circuit to ground or UB
The "Wheel speed right" sensor is
reporting a short circuit
KMC-522130-22 Cable break or short circuit to ground The "Weighing device acceleration"
sensor is reporting a cable break
KMC-522130-23 Cable break, short circuit to ground
or short circuit to UB
The "Weighing device acceleration"
sensor is reporting a short circuit.
KMC-522151-4 Switch/momentary switch
- A70.S201 Safety installation
wrapping arm 1
- A70.S202 Safety installation
wrapping arm 2
- Short circuit to ground or UB
The "Safety installation wrapping arm"
momentary switch is reporting a short
circuit
KMC-522151-24 Switch/momentary switch
- A70.S201 Safety installation
wrapping arm 1
- A70.S202 Safety installation
wrapping arm 2
- Short circuit to earth or short
circuit to UB
The "Safety installation wrapping arm"
momentary switch is reporting a cable
break
KMC-522153-4 Switch/momentary switch S3 Quick-
stop switch - Short circuit to ground
The "Quick-stop switch" momentary
switch is reporting a short circuit
KMC-522153-22 Switch/momentary switch S3 Quick-
stop switch - Cable break or short
circuit to ground
The "Quick-stop switch" momentary
switch is reporting a cable break
KMC-522154-3 Switch/momentary switch S4
Release button - lift/right/reverse/turn
- Cable break or short circuit to UB
The "Enable manual operation 1"
momentary switch is reporting a cable
break
KMC-522154-4 Switch/momentary switch S4
Release button - lift/right/reverse/turn
- Short circuit to ground
The "Enable manual operation 1"
momentary switch is reporting a short
circuit
KMC-522155-3 Switch/momentary switch S5
Release button - lower/left/forward/
reverse - Cable break or short circuit
to UB
The "Enable manual operation 2"
momentary switch is reporting a cable
break
Page 9
Error number Error text Description Figure
KMC-522155-4 Switch/momentary switch S5
Release button - lower/left/forward/
reverse - Short circuit to ground
The "Enable manual operation 2"
momentary switch is reporting a short
circuit
KMC-522250-16 Upper limit value exceeded
KMC-522250-18 Lower limit value below minimum
KMC-522251-16 Upper limit value exceeded
KMC-522251-18 Lower limit value below minimum
KMC-522301-3 Valve Q1 Load Sensing active - Cable
break or short circuit to UB
The "Load Sensing" actuator is
reporting a cable break
KMC-522301-6 Valve Q1 Load Sensing active - Short
circuit to ground
The "Load Sensing" actuator is
reporting a short circuit
KMC-522302-3 Valve Q2 Drive of wrapping arm -
Cable break or short circuit to UB
The "Wrapping arm drive" actuator is
reporting a cable break
KMC-522302-6 Valve Q2 Drive of wrapping arm -
Short circuit to ground
The "Wrapping arm drive" actuator is
reporting a short circuit
KMC-522303-3 Valve Q3 Wrapping table drive -
Cable break or short circuit to UB
The "Wrapping table drive" actuator is
reporting a cable break
KMC-522303-6 Valve Q3 Wrapping table drive - Short
circuit to ground
The "Wrapping table drive" actuator is
reporting a short circuit
KMC-522304-3 Valve Q4 Pressure supply valve -
Cable break or short circuit to UB
The "Pressure supply valve" actuator is
reporting a cable break
KMC-522304-6 Valve Q4 Pressure supply valve -
Short circuit to ground
The "Pressure supply valve" actuator is
reporting a short circuit
KMC-522305-3 Valve Q5 Pilot valve speed 1 - Cable
break or short circuit to UB
The "Pilot valve speed 1" actuator is
reporting a cable break
KMC-522305-6 Valve Q5 Pilot valve speed 1 - Short
circuit to ground
The "Pilot valve speed 1" actuator is
reporting a short circuit
KMC-522306-3 Valve Q6 Pilot valve direction 1 -
Cable break or short circuit to UB
The "Pilot valve direction 1" actuator is
reporting a cable break
Page 10
Error number Error text Description Figure
KMC-522306-6 Valve Q6 Pilot valve direction 1 -
Short circuit to ground
The "Pilot valve direction 1" actuator is
reporting a short circuit
KMC-522307-3 Valve Q7 Move lifting unit - Cable
break or short circuit to UB
The "Move holder bracket" actuator is
reporting a cable break
KMC-522307-6 Valve Q7 Move lifting unit - Short
circuit to ground
The "Move holder bracket" actuator is
reporting a short circuit
KMC-522308-3 Valve Q8 Move lifting arm - Cable
break or short circuit to UB
The "Move lifting arm" actuator is
reporting a cable break
KMC-522308-6 Valve Q8 Move lifting arm - Short
circuit to ground
The "Move lifting arm" actuator is
reporting a short circuit
KMC-522309-3 Valve Q9 Reverse wrapping arm -
Cable break or short circuit to UB
The "Reverse wrapping arm" actuator
is reporting a cable break
KMC-522309-6 Valve Q9 Reverse wrapping arm -
Short circuit to ground
The "Reverse wrapping arm" actuator
is reporting a short circuit
KMC-522310-3 Valve Q10 Speed drawbar - Cable
break or short circuit to UB
The "Drawbar speed" actuator is
reporting a cable break
KMC-522310-6 Valve Q10 Speed drawbar - Short
circuit to ground
The "Drawbar speed" actuator is
reporting a short circuit
KMC-522311-3 Valve Q11 Direction of motion of
drawbar - Cable break or short circuit
to UB
The "Drawbar direction of motion"
actuator is reporting a cable break
KMC-522311-6 Valve Q11 Direction of motion of
drawbar - Short circuit to ground
The "Drawbar direction of motion"
actuator is reporting a short circuit
KMC-522312-3 Valve Q12 Pilot valve speed 2 - Cable
break or short circuit to UB
The "Pilot valve speed 2" actuator is
reporting a cable break
KMC-522313-3 Valve Q13 Pilot valve direction 2 -
Cable break or short circuit to UB
The "Pilot valve direction 2" actuator is
reporting a cable break
KMC-522313-6 Valve Q13 Pilot valve direction 2 -
Short circuit to ground
The "Pilot valve direction 2" actuator is
reporting a short circuit
KMC-522314-3 Valve Q14 Move holding and cutting
device on left - Cable break or short
circuit to UB
The "Move holding and cutting device
left" actuator is reporting a cable break
KMC-522314-6 Valve Q14 Move holding and cutting
device on left - Short circuit to ground
The "Move holding and cutting device
left" actuator is reporting a short circuit
Page 11
Error number Error text Description Figure
KMC-522315-3 Valve Q15 Move right holding and
cutting device - Cable break or short
circuit to UB
The "Move holding and cutting device
right" actuator is reporting a cable
break
KMC-522315-6 Valve Q15 Move right holding and
cutting device - Short circuit to
ground
The "Move holding and cutting device
right" actuator is reporting a short
circuit
KMC-522316-3 Valve Q16 Move wrapping table -
Cable break or short circuit to UB
The "Move wrapping table" actuator is
reporting a cable break
KMC-522316-6 Valve Q16 Move wrapping table -
Short circuit to ground
The "Move wrapping table" actuator is
reporting a short circuit
KMC-522317-3 Valve Q17 Move bale turner - Cable
break or short circuit to UB
The "move bale turner" actuator
signals a cable break.
KMC-522317-6 Valve Q17 Move bale turner - Short
circuit to ground
The "move bale turner" actuator
signals a short circuit
KMC-522351-3 Lamp
- E1 Working light 1
- E2 Working light 2
- Cable break or short circuit to UB
The "Working light 1/2" actuator is
reporting a cable break
KMC-522351-6 Lamp
- E1 Working light 1
- E2 Working light 2
- Short circuit to ground
The "Working light 1/2" actuator is
reporting a short circuit
KMC-522352-6 Lamp E7 Working light 3 - Short
circuit to ground
The "Working light 3" actuator is
reporting a short circuit
KMC-522355-5 The "Additional function right" actuator
is reporting a cable break
KMC-522500-13 The wrong configuration values were
saved
KMC-522503-31 ISOBUS terminal, connection
interrupted
KMC-522504-31 AUX connection interrupted
KMC-522505-31 ISOBUS TC, connection interrupted
KMC-522506-31 ISOBUS TECU, connection interrupted
KMC-522560-19 FMA 1 - Malfunction
Page 12
Error number Error text Description Figure
KMC-522561-4 FMA 1 - Undervoltage
KMC-522562-12 FMA 1 - Internal Error
KMC-522563-3 FMA 1 - Overvoltage
KMC-522650-3 Overvoltage KP1 overvoltage
KMC-522650-4 Undervoltage KP1 undervoltage
KMC-522650-12 Internal Error KP1 general error
KMC-522650-19 KP1 timeout
4 Index
20
Bale wrapper
Supplement to operating instructions 150001621_01_en
4 Index
A
Acknowledging error message ............................. 5
Applicable documents .......................................... 3
E
Error list ................................................................ 6
Error messages .................................................... 5
I
Information on this document ............................... 3
M
Meaning of the supplement to the operating
instructions ........................................................... 4
P
Possible error types (FMI) .................................... 6
R
Re-ordering .......................................................... 3
S
Safety ................................................................... 4
V
Validity.................................................................. 3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Krone Messages - Parameters Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI