Krone Messages - Parameters provides real-time monitoring and control of your Krone machine's parameters, allowing you to optimize performance and efficiency. With a user-friendly interface, you can easily access and adjust settings, monitor machine status, receive error messages, and even perform remote diagnostics. The device can also store and export data for further analysis, helping you identify trends and make informed decisions.

Krone Messages - Parameters provides real-time monitoring and control of your Krone machine's parameters, allowing you to optimize performance and efficiency. With a user-friendly interface, you can easily access and adjust settings, monitor machine status, receive error messages, and even perform remote diagnostics. The device can also store and export data for further analysis, helping you identify trends and make informed decisions.

Enclose this document with the operating instructions of the
machine.
Supplement to operating
instructions
Document number: 150001727_02_en
Version: 14/06/2023
Pelleting press
Software version: D2515020112400006
Error messages and information messages
Table of contents
2
Pelleting press
Supplement to operating instructions 150001727_02_en
1 Information on this document ..................................................................................................3
1.1 Validity .........................................................................................................................................3
1.2 Re-ordering ..................................................................................................................................3
1.3 Applicable documents..................................................................................................................3
2 Safety ..........................................................................................................................................4
2.1 Meaning of the supplement to the operating instructions ............................................................4
3 Error messages..........................................................................................................................5
3.1 Possible error types (FMI)............................................................................................................6
3.2 Error list........................................................................................................................................6
4 Information messages.............................................................................................................24
4.1 Information list............................................................................................................................24
5 Index..........................................................................................................................................27
Information on this document 1
Validity 1.1
Pelleting press
Supplement to operating instructions 150001727_02_en 3
1 Information on this document
1.1 Validity
This document is valid for:
PP201-20 (Premos 5000)
1.2 Re-ordering
You can request a replacement document if this document became completely or partly
unusable, or if you need it in a different language. Please specify the document number shown
on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.mykrone.green.
1.3 Applicable documents
To ensure that the machine is used safely and as intended, observe the following further
applicable documents.
Operating instructions of the respective machine
2 Safety
2.1 Meaning of the supplement to the operating instructions
4
Pelleting press
Supplement to operating instructions 150001727_02_en
2 Safety
WARNING
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions
must be read and observed.
WARNING
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read
and observed.
INFO
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating
instructions.
2.1 Meaning of the supplement to the operating instructions
The supplement to the operating instructions is an important document and a part of the
machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured
or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time,see Page3.
Before working, also read and observe the respective sections of the corresponding
operating instructions,see Page3.
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
Error messages 3
Pelleting press
Supplement to operating instructions 150001727_02_en 5
3 Error messages
WARNING
Risk of injury to persons and damage to machines if error messages are ignored
If error messages are ignored and the fault is not rectified, there is a risk of injury to persons
and/or severe damage to the machine.
Eliminate the disturbance when an error message is displayed, see Page6.
If the fault cannot be rectified, contact KRONE service partner.
Premos
KMC - 522001-16
EQG000-034
The display shows an error message when a disturbance occurs on the machine. At the same
time, an audible signal sounds (continuous horn signal). For a list of the error messages, see
Page6.
Configuration of an error message
The error message is configured according to the following sample: e.g. error message
"520192-19
CAN1
"
520192 19
CAN1
SPN (Suspect Parameter
Number) = error number
FMI = type of error, see
Page6
Icon
Acknowledging error message
Note down the error message.
Briefly press on .
ÆThe acoustic signal stops and the error display is no longer indicated. The error message is
displayed again if the fault occurs again.
Rectify the error, see Page6.
Acknowledged and still pending error messages can be displayed again via the "Error list" menu
or the status line.
The following key functions can be selected:
3 Error messages
3.1 Possible error types (FMI)
6
Pelleting press
Supplement to operating instructions 150001727_02_en
Icon Designation Explanation
Acknowledging error mes-
sage
If the fault occurs again, the error message
will be displayed again.
Deleting error message The error message will no longer be dis-
played until the operating terminal is next
started.
3.1 Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI Meaning
0 The upper limit value was greatly exceeded.
1 The lower limit value was far below the required one.
2 The data is not permitted.
3 There is an overvoltage or a short circuit to supply voltage.
4 There is an undervoltage or a short circuit to ground.
5 A cable is broken or amperage is too low.
6 There is a short circuit to ground or amperage is too low.
7 The mechanics do not respond or the expected result was not achieved.
8 The frequency is not permitted.
9 There is an abnormal update rate.
10 There is an abnormal rate of change.
11 The error cause is unknown.
12 There is an internal error.
13 The values of the calibration are outside the value range.
14 Particular instructions are required.
15 The upper limit value has been reached.
16 The upper limit value has been exceeded.
17 The lower limit value has been reached.
18 The lower limit value has not been reached.
19 There is a CAN communication failure.
20 The data deviates upwards.
21 The data deviates downwards.
31 The condition has been fulfilled.
3.2 Error list
Overview of the control units
Abbreviation Explanation
KMC KRONE Machine Controller
Error messages 3
Error list 3.2
Pelleting press
Supplement to operating instructions 150001727_02_en 7
>>>
2KMC [}8]
Error list
Software version: D2515020141800006_200,
D2515020112500006_200
Control unit: KMC
Page 1
Error number Error text Description Figure
KMC-520192-19 CAN 1 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 1.
KMC-520193-19 CAN 2 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 2.
KMC-520194-19 CAN 3 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 3.
KMC-520195-19 CAN 4 - CAN disturbance between
control units
There is a CAN disturbance between
control units on CAN 4.
KMC-520198-12 Control unit - Internal Error An internal error in the control unit
which was actuated by defective
software or hardware.
KMC-520232-12 Vehicle identification number -
Internal Error
Vehicle identification number has not
been initialised.
KMC-520234-31 System check with KMC failed With the KMC the cross-controller
adjustment of system-relevant
machine data has failed.
KMC-521100-3 Voltage group UB1 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521100-4 Voltage group UB1 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521100-5 Voltage group UB1 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521100-6 Voltage group UB1 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521101-3 Voltage group UB2 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521101-4 Voltage group UB2 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521101-5 Voltage group UB2 - Ground fault The maximum load on the supply
voltage has been exceeded.
KMC-521101-6 Voltage group UB2 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521102-3 Voltage group UB3 - Overvoltage The input voltage of the corresponding
voltage group is too high.
Page 2
Error number Error text Description Figure
KMC-521102-4 Voltage group UB3 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521102-5 Voltage group UB3 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521102-6 Voltage group UB3 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521103-3 Voltage group UB4 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521103-4 Voltage group UB4 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521103-5 Voltage group UB4 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521103-6 Voltage group UB4 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521104-3 Voltage group UB5 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521104-4 Voltage group UB5 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521104-5 Voltage group UB5 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521104-6 Voltage group UB5 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521105-3 Voltage group UB6 - Overvoltage The input voltage of the corresponding
voltage group is too high.
KMC-521105-4 Voltage group UB6 - Undervoltage The input voltage of the corresponding
voltage group is too low.
KMC-521105-5 Voltage group UB6 - Ground fault A ground fault has occurred on the
supply voltage.
KMC-521105-6 Voltage group UB6 - Overload The maximum load on the supply
voltage has been exceeded.
KMC-521106-11 Supply voltage sensors - General
disturbance
The voltage has been switched off due
to an overload or a short circuit on the
supply voltage of the sensors.
Page 3
Error number Error text Description Figure
KMC-521107-3 Supply voltage - Overvoltage The power supply on the UE
connection is too high.
KMC-521107-4 Supply voltage - Undervoltage The power supply on the UE
connection is too low.
KMC-521108-11 Control unit - General disturbance The voltage group relay UB1 has not
passed the self-test.
KMC-521109-11 Control unit - General disturbance The voltage group relay UB2 has not
passed the self-test.
KMC-521110-11 Control unit - General disturbance The voltage group relay UB3 has not
passed the self-test.
KMC-521111-11 Control unit - General disturbance The voltage group relay UB4 has not
passed the self-test.
KMC-521112-11 Control unit - General disturbance The voltage group relay UB5 has not
passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not
passed the self-test.
KMC-521114-11 Sensor supply voltage Uext1 -
General disturbance
The voltage group Uext1 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521115-11 Sensor supply voltage Uext2 -
General disturbance
The voltage group Uext2 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521116-11 Sensor supply voltage Uext3 -
General disturbance
The voltage group Uext3 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521117-11 Sensor supply voltage Uext4 -
General disturbance
The voltage group Uext4 for supplying
the sensors is defective, for example
due to overload or short circuit.
KMC-521320-2 Machine configuration - Logic error
electronics
Configuration of the machine is not
compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
KMC-521351-11 Control unit - General disturbance
KMC-522001-16 Rotational speed universal shaft -
Upper limit value exceeded
The rotational speed of the universal
shaft is too high for the current state of
the machine.
Page 4
Error number Error text Description Figure
KMC-522011-7 Auxiliary drive position - Logic fault
mechanics
The auxiliary drive is in the swivelled-in
position in the flywheel. The position is
not compatible with the state of the
machine.
KMC-522012-7 Discharge flap position - Logic fault
mechanics
The discharge flap is open. This
position does not correspond to the
condition of the machine.
KMC-522013-16 Steering axle timeout - Upper limit
value exceeded
The steering axle could not be locked/
released within the specified time.
KMC-522015-7 Flywheel - Logic fault mechanics Only the universal shaft and the
flywheel rotate on the machine. The
shear bolts are broken. The machine
cannot be operated properly.
KMC-522016-7 Transfer conveyor position - Logic
fault mechanics
The transfer conveyor is not closed.
This position does not correspond to
the condition of the machine.
KMC-522018-7 Outlet slide position - Logic fault
mechanics
The outlet slide is not closed. This
position does not correspond to the
condition of the machine.
KMC-522019-16 Moistening system - Upper limit
value exceeded
The moistening unit switched off due to
overvoltage.
KMC-522020-18 Moistening system tank - Lower limit
value below minimum
The flow sensor of the moistening unit
does not sense any flow. The additives
tank is empty or the lines are
obstructed.
KMC-522021-7 Safety check Q13 - Logic fault
mechanics
The safety check for valve Q13
"Folding transfer conveyor" could not
be carried out successfully. Driving
safely on public roads cannot be
guaranteed.
KMC-522022-7 Safety check Q17 - Logic fault
mechanics
The safety check for valve Q17 "Pilot
valve 2" could not be carried out
successfully. Driving safely on public
roads cannot be guaranteed.
KMC-522023-7 Hopper weight - Logic fault
mechanics
The hopper weighs more than 500 kg.
The pelleting press may only be moved
on a public road when the hopper is
empty.
KMC-522024-7 Position of hopper conveyor belt -
Logic fault mechanics
The hopper conveyor belt has been
extended. The position is not
compatible with the state of the
machine.
KMC-522025-18 Filling level main gearbox - Lower
limit value below minimum
The filling level at the main gearbox of
the pelleting press has fallen under the
bottom limit.
KMC-522026-18 Gearbox oil pressure monitoring -
Lower limit value below minimum
The pressure in the gearbox oil
lubrication has fallen under the bottom
limit.
KMC-522027-16 Filter monitoring working hydraulics -
Upper limit value exceeded
The differential pressure over the filter
element of the working hydraulics has
exceeded the top limit.
Page 5
Error number Error text Description Figure
KMC-522028-18 Central lubrication - Lower limit value
below minimum
The central lubrication did not reach all
lubrication points within the specified
time.
KMC-522029-18 Feed rotor standstill - Lower limit
value below minimum
KMC-522030-16 Feed rotor overspeed - Upper limit
value exceeded
Too high a rotational speed of the feed
rotor was sensed. The feed rotor was
switched off.
KMC-522031-7 Safety check Q18 - Logic fault
mechanics
The safety check for the valve Q18
"Feed rotor drive" could not be carried
out successfully.
KMC-522032-7 Safety check Q6 - Logic fault
mechanics
The safety check for valve Q6 "Pilot
valve 3" could not be carried out
successfully.
KMC-522033-7 Auxiliary drive invalid position - Logic
fault mechanics
The position of the auxiliary drive
cannot be determined unambiguously.
This position does not correspond to
the condition of the machine.
KMC-522034-2 Button clamp release button manual
operation - Logic error electronics
The release button for manual
operation is pressed permanently.
KMC-522035-2 Incompatible machine compound -
Communication error
The overall software versions of the
products Premos 5000 and KRONE
BaleFeed are not compatible with each
other. Communication between the two
products is not possible.
KMC-522036-18 Rotational speed of universal shaft is
too low - Lower limit value below
minimum
The determined rotational speed of the
universal shaft is too low for the
condition of the machine.
KMC-522037-18 Rotational speed of flywheel is too
low - Lower limit value below
minimum
The determined rotational speed of the
flywheel is too low for the condition of
the machine.
KMC-522038-16 Main gearbox filter monitoring - Upper
limit value exceeded
The differential pressure across the
filter element of the main gearbox filter
exceeded its upper limit.
KMC-522040-7 Safety check Q24 - Logic fault
mechanics
The safety check for valve Q24
"Reverse feed rotor" could not be
carried out successfully.
KMC-522101-3 Sensor B1 Rotational speed of PTO
shaft - Cable break
KMC-522101-4 Sensor B1 Rotational speed of PTO
shaft - Short circuit to ground or UB
KMC-522102-3 Sensor B2 Rotational speed of
flywheel - Cable break
KMC-522102-4 Sensor B2 Rotational speed of
flywheel - Short circuit to ground or
UB
Page 6
Error number Error text Description Figure
KMC-522104-3 Sensor B4 Rotational speed of
elevator - Cable break
KMC-522104-4 Sensor B4 Rotational speed of
elevator - Short circuit to ground or
UB
KMC-522105-3 Sensor B5 Rotational speed of feed
rotor - Cable break
KMC-522105-4 Sensor B5 Rotational speed of feed
rotor - Short circuit to ground
KMC-522106-3 Sensor B6 Rotational speed of crop
conveyor - Cable break
KMC-522106-4 Sensor B6 Rotational speed of crop
conveyor - Short circuit to ground or
UB
KMC-522108-3 Sensor B8 Discharge flap closed -
Cable break
KMC-522108-4 Sensor B8 Discharge flap closed -
Short circuit to ground or UB
KMC-522110-3 Sensor B10 Reversing device
swivelled in - Cable break
KMC-522110-4 Sensor B10 Reversing device
swivelled in - Short circuit to ground
or UB
KMC-522112-3 Sensor B12 Position of pressure roll
on left - Cable break
KMC-522112-4 Sensor B12 Position of pressure roll
on left - Short circuit to ground or UB
KMC-522113-3 Sensor B13 Filling level of additional
tank 1 - Cable break
KMC-522113-4 Sensor B13 Filling level of additional
tank 1 - Short circuit to ground or UB
KMC-522114-3 Sensor B14 Filling level of additional
tank 2 - Cable break
KMC-522114-4 Sensor B14 Filling level of additional
tank 2 - Short circuit to ground or UB
Page 7
Error number Error text Description Figure
KMC-522115-3 Sensor B15 Filling level of additional
tank 3 - Cable break
KMC-522115-4 Sensor B15 Filling level of additional
tank 3 - Short circuit to ground or UB
KMC-522116-3 Sensor B16 Temperature
measurement of pellet press roller -
Short circuit to UB
KMC-522116-4 Sensor B16 Temperature
measurement of pellet press roller -
Cable break or short circuit to ground
KMC-522118-3 Sensor B18 Flow rate of additive -
Cable break
KMC-522118-4 Sensor B18 Flow rate of additive -
Short circuit to ground or UB
KMC-522119-3 Sensor B19 Central lubrication unit
active - Cable break
KMC-522119-4 Sensor B19 Central lubrication unit
active - Short circuit to ground or UB
KMC-522122-3 Sensor B22 Pressure of steering axle
- Cable break
KMC-522122-4 Sensor B22 Pressure of steering axle
- Short circuit to ground or UB
KMC-522127-3 Sensor B27 Position of transfer
conveyor belt closed - Cable break
KMC-522127-4 Sensor B27 Position of transfer
conveyor belt closed - Short circuit to
ground or UB
KMC-522128-3 Sensor B28 Side hood on right
closed - Cable break
KMC-522128-4 Sensor B28 Side hood on right
closed - Short circuit to ground or UB
KMC-522130-3 Sensor B30 Outlet slide closed -
Cable break
KMC-522130-4 Sensor B30 Outlet slide closed -
Short circuit to ground or UB
Page 8
Error number Error text Description Figure
KMC-522135-3 Sensor B35 Gearbox oil pressure
monitoring - Short circuit to UB
KMC-522135-4 Sensor B35 Gearbox oil pressure
monitoring - Cable break or short
circuit to ground
KMC-522136-3 Sensor B36 Filter monitoring working
hydraulics - Cable break
KMC-522136-4 Sensor B36 Filter monitoring working
hydraulics - Short circuit to ground or
UB
KMC-522137-3 Sensor B37 Reversing device
swivelled out - Cable break
KMC-522137-4 Sensor B37 Reversing device
swivelled out - Short circuit to ground
or UB
KMC-522138-3 Sensor B38 Hopper conveyor belt
down - Cable break
KMC-522138-4 Sensor B38 Hopper conveyor belt
down - Short circuit to ground or UB
KMC-522139-3 Sensor B39 Filling level switch gear
oil - Short circuit to UB
KMC-522139-4 Sensor B39 Filling level switch gear
oil - Cable break or short circuit to
ground
KMC-522140-3 Sensor B40 Pressure moistening unit
- Short circuit to UB
KMC-522140-4 Sensor B40 Pressure moistening unit
- Cable break or short circuit to
ground
KMC-522142-3 Sensor B42 Main gearbox filter
monitoring - Cable break
KMC-522142-4 Sensor B42 Main gearbox filter
monitoring - Short circuit to ground or
UB
KMC-522144-3 Sensor B44 Pressure additional
moistening unit - Short circuit to UB
KMC-522144-4 Sensor B44 Pressure additional
moistening unit - Cable break or
short circuit to ground
Page 9
Error number Error text Description Figure
KMC-522181-3 Switch/momentary switch S1
Reversing forwards - Cable break or
short circuit to UB
KMC-522181-4 Switch/momentary switch S1
Reversing forwards - Short circuit to
ground
KMC-522182-3 Switch/momentary switch S2
Reversing backwards - Cable break
or short circuit to UB
KMC-522182-4 Switch/momentary switch S2
Reversing backwards - Short circuit
to ground
KMC-522183-3 Switch/momentary switch S3 Enable
manual operation - Short circuit to
UB
KMC-522183-4 Switch/momentary switch S3 Enable
manual operation - Cable break or
short circuit to ground
KMC-522184-3 Switch/momentary switch A3.S1
Quick-stop switch remote control -
Cable break
KMC-522184-4 Switch/momentary switch A3.S1
Quick-stop switch remote control -
Short circuit to ground or UB
KMC-522301-3 Valve Q1 Valve additional tank 1 -
Cable break or short circuit to UB
KMC-522301-6 Valve Q1 Valve additional tank 1 -
Short circuit to ground
KMC-522302-3 Valve Q2 Valve additional tank 2 -
Cable break or short circuit to UB
KMC-522302-6 Valve Q2 Valve additional tank 2 -
Short circuit to ground
KMC-522303-3 Valve Q3 Valve additional tank 3 -
Cable break or short circuit to UB
KMC-522303-6 Valve Q3 Valve additional tank 3 -
Short circuit to ground
KMC-522304-3 Valve Q4 Central lubrication unit -
Cable break or short circuit to UB
KMC-522304-6 Valve Q4 Central lubrication unit -
Short circuit to ground
Page 10
Error number Error text Description Figure
KMC-522305-3 Valve Q5 Load Sensing active - Cable
break or short circuit to UB
KMC-522305-6 Valve Q5 Load Sensing active - Short
circuit to ground
KMC-522306-3 Valve Q6 Pilot valve 3 - Cable break
or short circuit to UB
KMC-522306-6 Valve Q6 Pilot valve 3 - Short circuit
to ground
KMC-522307-3 Valve Q7 Drive hopper conveyor belt -
Cable break or short circuit to UB
KMC-522307-6 Valve Q7 Drive hopper conveyor belt -
Short circuit to ground
KMC-522308-3 Valve Q8 Drive transfer conveyor -
Cable break or short circuit to UB
KMC-522308-6 Valve Q8 Drive transfer conveyor -
Short circuit to ground
KMC-522309-3 Valve Q9 Opening/closing discharge
flap - Cable break or short circuit to
UB
KMC-522309-6 Valve Q9 Opening/closing discharge
flap - Short circuit to ground
KMC-522310-3 Valve Q10 Adjusting reversing device
- Cable break or short circuit to UB
KMC-522310-6 Valve Q10 Adjusting reversing device
- Short circuit to ground
KMC-522311-3 Valve Q11 Steering axle - Cable
break or short circuit to UB
KMC-522311-6 Valve Q11 Steering axle - Short
circuit to ground
KMC-522312-3 Valve Q12 Adjustment of hopper
conveyor belt - Cable break or short
circuit to UB
KMC-522312-6 Valve Q12 Adjustment of hopper
conveyor belt - Short circuit to ground
Page 11
Error number Error text Description Figure
KMC-522313-3 Valve Q13 Folding transfer conveyor
belt - Cable break or short circuit to
UB
KMC-522313-6 Valve Q13 Folding transfer conveyor
belt - Short circuit to ground
KMC-522314-3 Valve Q14 Opening/closing outlet
slide - Cable break or short circuit to
UB
KMC-522314-6 Valve Q14 Opening/closing outlet
slide - Short circuit to ground
KMC-522318-3 Valve Q18 Drive feed rotor - Cable
break or short circuit to UB
KMC-522318-6 Valve Q18 Drive feed rotor - Short
circuit to ground
KMC-522322-3 Valve Q22 Drive reversing device -
Cable break or short circuit to UB
KMC-522322-6 Valve Q22 Drive reversing device -
Short circuit to ground
KMC-522323-3 Valve Q23 Direction of rotation of feed
rotor - Cable break or short circuit to
UB
KMC-522323-6 Valve Q23 Direction of rotation of feed
rotor - Short circuit to ground
KMC-522324-3 Valve Q24 Reversing the feed rotor -
Cable break or short circuit to UB
KMC-522324-6 Valve Q24 Reversing the feed rotor -
Short circuit to ground
KMC-522344-3 Valve Q16 Pilot valve 1 - Cable break
or short circuit to UB
KMC-522344-6 Valve Q16 Pilot valve 1 - Short circuit
to ground
KMC-522345-3 Valve Q17 Pilot valve 2 - Cable break
or short circuit to UB
KMC-522345-6 Valve Q17 Pilot valve 2 - Short circuit
to ground
Page 12
Error number Error text Description Figure
KMC-522353-3 Valve Q15 Pilot valve of reversing
device - Cable break or short circuit
to UB
KMC-522353-6 Valve Q15 Pilot valve of reversing
device - Short circuit to ground
KMC-522361-3 Lamp
- E1 Working light 1
- E6 Working light 2
- E7 Working light rear right
- E8 Working light rear left
- Cable break or short circuit to UB
KMC-522361-6 Lamp
- E1 Working light 1
- E6 Working light 2
- E7 Working light rear right
- E8 Working light rear left
- Short circuit to ground
KMC-522362-3 Lamp
- E2 Maintenance lighting left
- E3 Maintenance lighting right
- Cable break or short circuit to UB
KMC-522362-6 Lamp
- E2 Maintenance lighting left
- E3 Maintenance lighting right
- Short circuit to ground
KMC-522363-3 Lamp
- E4 Warning beacon left
- E5 Warning beacon right
- Cable break or short circuit to UB
KMC-522363-6 Lamp
- E4 Warning beacon left
- E5 Warning beacon right
- Short circuit to ground
KMC-522364-3 Valve Q21 Drive pump moistening
unit - Cable break or short circuit to
UB
KMC-522364-6 Valve Q21 Drive pump moistening
unit - Short circuit to ground
KMC-522365-3 Valve Q19 Crop conveyor nozzle -
Cable break or short circuit to UB
KMC-522365-6 Valve Q19 Crop conveyor nozzle -
Short circuit to ground
KMC-522366-3 Valve Q20 Nozzle pellet press rollers
- Cable break or short circuit to UB
KMC-522366-6 Valve Q20 Nozzle pellet press rollers
- Short circuit to ground
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Krone Messages - Parameters Operating instructions

Type
Operating instructions

Krone Messages - Parameters provides real-time monitoring and control of your Krone machine's parameters, allowing you to optimize performance and efficiency. With a user-friendly interface, you can easily access and adjust settings, monitor machine status, receive error messages, and even perform remote diagnostics. The device can also store and export data for further analysis, helping you identify trends and make informed decisions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI