Error number Error text Description Figure
KMC-522002-19 Timeout KMB 1 - CAN disturbance
between control units
Timeout KMB 1
KMC-522007-7 Logic fault mechanics A quick stop has been triggered.
KMC-522009-7 Button clamp release button Switch/
momentary switch S6 Enable manual
operation - Logic fault mechanics
Button clamp release button manual
operation
KMC-522010-7 Logic fault mechanics The holding and cutting device is not
detected as closed.
KMC-522011-2 Timeout automatic - Logic error
electronics
An automatic process takes longer
than expected.
KMC-522012-7 Rotational speed deviation of rollers -
Logic fault mechanics
The rotational speed deviation of the
rollers to the wrapping arm is too high.
KMC-522013-7 Wrapping arm not in transport
position - Logic fault mechanics
The wrapping arm is not in transport
position.
KMC-522014-7 Rotational speed deviation wrapping
arm - Logic fault mechanics
The speed of the wrapping arm
deviates from the default.
KMC-522015-7 Wrapping arm valve fault Valve Q2
Speed of wrapping arm - Logic fault
mechanics
The wrapping arm speed valve does
not close correctly.
KMC-522016-7 Holding and cutting device time-out -
Logic fault mechanics
The holding and cutting device could
not perform the requested action within
the specified time.
KMC-522017-7 Safety check pilot valve speed Valve
Q10 Pilot valve speed - Logic fault
mechanics
The pilot valve speed safety check
failed
KMC-522018-2 Logic error electronics
KMC-522101-3 Sensor A70.B3 Position wrapping
arm - Short circuit to UB
The "Wrapping arm position" sensor is
reporting a short circuit
KMC-522101-4 Sensor A70.B3 Position wrapping
arm - Cable break or short circuit to
ground
The "Wrapping arm position" sensor is
reporting a cable break
KMC-522102-3 Sensor B2 Bale in pick-up position -
Cable break
KMC-522102-4 Sensor B2 Bale in pick-up position -
Short circuit to ground or UB