Huawei OptiX RTN 905 Quick Installation Manual

Type
Quick Installation Manual
HUAWEI TECHNOLOGIES CO., LTD.
OptiX RTN 905 Radio Transmission System V100
Quick Installation Guide
for Outdoor Cabinets (OMB Cabinets)
Issue: 01
Date: 2018-10-30
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitutea warranty of any kind, express or implied.
1
Precautions
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility
of accidents.
The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be
followed. They only provide the generic safety precautions for operations.
When operating Huawei products and equipment, you must comply with safety precautions and special safety
instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are
related to only Huawei products. Huawei is not liable for any consequence that results from the violation of
universal regulations for safety operations and safety codes on design, production, and equipment use.
Complying with the Local Safety Regulations
When operating the product or equipment, comply with local safety regulations.
Qualified Personnel Only
Installation and maintenance personnel must be trained to perform operations correctly and safely.
Personnel Safety
The high-voltage power supply provides power for running the system. Avoid direct contact with the high-voltage
power supply or contact through damp objects. Failure to do so causes serious injury or death.
Non-standard and incorrect operations on the high-voltage power supply may result in fire and electric shock.
Do not perform operations on high-voltage and AC power supply facilities or on a tower or mast in the case of
thunderstorm. Failure to do so causes serious injury or death.
Ground the device before powering it on. Failure to do so causes damage to the device or personal injury.
Power off the device before performing operations on the power supply facilities.
Personnel Safety
High power radio-frequency signals are harmful to the human body. Ensure that the transmitter antennas are
muted before installing or maintaining an antenna on a tower or mast that holds a large number of transmitter
antennas.
Do not stand close to, or look into the optical fiber outlet without eye protection when handling optical fibers.
Take preventive measures when drilling holes. Otherwise, dust may hurt your eyes or you may inhale the dust.
When working at heights, be cautious about falling objects.
Device Safety
Check the electrical connection of the device before operation and ensure that the device is securely grounded.
The static electricity discharged from the human body may damage the electrostatic sensitive components, such
as large-scale integrated circuits (LSIs), on the circuit board. Wear an ESD wrist strap or ESD gloves when
handling a circuit board.
2
Tools for Installation
Network cable tester COAX stripper
Measuring tape
Phillips screwdriver Flat-head screwdriver Adjustable WrenchLevel
COAX crimping tool
Socket wrench
Torque wrench Hex key Wire clippers
Wire stripper
RJ45 crimping tool
Diagonal pliers Cold press pliers Needle-nose pliers
Combination pliers Bayonet w rench
Utility knife Claw hammerHammer drill Marker
Ladder Soldering iron
ESD gloves
Heat gunMultimeter
ESD gloves
Binding strap Insulation tape
ESD wrist strap
Impact tool
File
Vacuum cleaner
3
Introduction to the Equipment
1
Introduction to the RTN 905
Front View of the RTN 905 1A
a
Front View of the RTN 905 2A
b
NMS/COM
EXT/S1
CLK/TOD/MON
ALMI/ALMO
GE1
GE2
GE3
GE4
GE5 GE6 TDMA TDMB
OptiX RTN 905
1 A
STAT
SRV
PWRA
PWRB
L/A5
L/A6
USB
RTNB
(+)
NEGB
(-)
RTNA
(+)
NEGA
(-)
OUT IN OUT IN
-48V -60V
1
16
ESD
TURN OFF POWER BEFORE
WARNING
-48V OUTPUT
DISCONNECTING IF CABLE
!
LINK
ODU
10
11
12
13
NE cascading
port/Asynchronous
data port
10
11
External clock port/
external time port/ outdoor
cabinet monitoring port
NMS port/NMS serial
port
Ground screw
Port for the ESD
wrist strap
16xE1 ports
USB port
GE/FE service ports
(SFP modules)
TDM service
concatenation ports
IF port to the ODU
DC-C power socket
FE/GE service electrical
ports (RJ45 connectors)
12
13
Alarm
input/output port
NMS/COM
EXT/S1
CLK/TOD/MON
ALMI/ALMO
GE1
GE2
GE3
GE4
GE5 GE6 TDMA TDMB
OptiX RTN 905
2 A
STAT
SRV
PWRA
PWRB
L/A5
L/A6
USB
RTNB
(+)
NEGB
(-)
RTNA
(+)
NEGA
(-)
OUT IN OUT IN
-48V -60V
1
16
ESD
TURN OFF POWER BEFORE
WARNING
-48V OUTPUT
DISCONNECTING IF CABLE
!
OFF
ODU-1
ON
PULL
ODU-2
ON
PULL
OFF
ACT1
LINK2
ACT2
LINK1
10
11
12
13
14
USB port
10
11
NMS port/NMS
serial port
ODU power switch
Ground screw
16xE1 ports
TDM service
concatenation ports
IF port to the ODU
FE/GE service electrical
ports (RJ45 connectors)
GE/FE service ports (SFP
modules)
DC-C power socket
Port for the ESD
wrist strap
External clock port/
external time port/ outdoor
cabinet monitoring port
12
13
NE cascading
port/Asynchronous
data port
14
Alarm
input/output port
4a
Introduction to the Equipment
Front View of the RTN 905 1C
c
Ground screw
DC-C power socket
(Caution! See "Precautions
for Handling Power
Cables.")
NE status indicator
USB port
FE/GE service
electrical ports (RJ-45
connectors)
GE/FE service ports
(SFP modules)
TDM service
concatenation ports
1
2
3
5
IF port to the ODU/
XPIC input/output
ports
6
Radio link status
indicator
7
8
Status indicators of
the GE/FE service
ports (SFP
modules)
9
USB port status
indicator
10
11
12
NMS port/NMS
serial port
NE cascading port/
Asynchronous data port
Clock port (CLK)/High-precision
time port (TOD)/Outdoor cabinet
monitoring port (MON)
16
17
16xE1 ports
4
Alarm input/output
port
13
14
15
1
2
3
4
5
6
7
9
10
11
13
16
12
14
15
17
19
18
18
Port for the ESD wrist
strap
19
STM-1 service ports
1+1 / TDM service
concatenation ports
Front View of the IDU 905 1E
d
Ground screw
DC-C power socket
(Caution! See "Precautions
for Handling Power
Cables.")
NE status indicator
1
2
3
1
2
3
4
5
6
7
8
9
10
11
13
16
12
14
15
17
19
18
Mini USB port
FE/GE service
electrical ports (RJ-45
connectors)
GE/FE service ports
(SFP modules)
STM-1 service ports
5
IF port to the ODU /
XPIC input/output
ports
6
Radio link status
indicator
7
8
Status indicators of
the GE/FE service
ports (SFP
modules)
9
USB port/Status
indicator
10
11
12
NMS port/NMS serial
port
NE cascading port/
Asynchronous data
port
Clock port (CLK)/High-precision
time port (TOD)/Outdoor cabinet
monitoring port (MON)
16
17
16xE1 ports
4
Alarm input/output
port
13
14
15
18
COMBO ports
Port for the ESD wrist
strap
19
MN1 subboard
4b
Front View of the IDU 905 2E
e
Ground screw
DC-C power socket
(Caution! See "Precautions
for Handling Power
Cables.")
NE status indicator
1
2
3
1
2
3
4
5
6
7
9
10
11
13
16
12
14
15
17
19
18
Mini USB port
5
IF ports to the
ODU/ODU switches
6
Radio link status
indicator
7
8
Status indicators of
the GE/FE service
ports (SFP
modules)
9
USB port/Status
indicator
10
11
12
NMS port/NMS serial
port
NE cascading port/
Asynchronous data port
Clock port (CLK)/High-precision
time port (TOD)/Outdoor cabinet
monitoring port (MON)
4
Alarm input/output
port
Power over Ethernet
port
GE/FE service ports
(SFP modules)
STM-1 service ports
16
17
16xE1 ports
13
14
15
18
COMBO ports
Port for the ESD wrist
strap
19
MN1 subboard
20
FE/GE service
electrical ports (RJ-45
connectors)
20
5
2
Introduction to the OMB Cabinet
Front View of the OMB Cabinet
a
Left View of the OMB Cabinet
b
Right View of the OMB Cabinet
c
Technical Specifications
Dimensions (mm): 600 (H) x 240 (W) x 430(D)
Ambient temperature (no sunshine radiation): -20 to +50
6
About the Internal Structure of the OMB Cabinet
d
Fan assembly (internal circulating)
Internal Structure of the OMB Cabinet (AC Power Supply)
Internal Structure of the OMB Cabinet (DC Power Supply)
HEUA
OMB cabinet (AC power supply)
Fan assembly (external circulating)
AC/DC power supply facility
PMU module
Fan assembly (internal circulating)
HEUA
OMB cabinet (DC power supply)
Fan assembly (external circulating)
DCDU-03B
Cable trough
AC surge protection box
7
Installation Scenarios of the Cabinets
1
Installation Scenarios of the OMB Cabinet
Recommended Requirements of
the OMB Cabinet
a
Minimum Requirements of the
OMB Cabinet
b
200 mm
150 mm
600 mm
500 mm
200 mm
300 mm
800 mm
600 mm
8
Installation Modes
d
Installing the OMB cabinet on a pole
Installing the OMB cabinet on a wall
The OMB cabinet provides a small space. Therefore, do not use the OMB cabinet in an area where the
ambient temperature is lower than 20°C in winter. It is recommended that you use the APM30H or TMC11H
cabinet that is configured with a heater.
2
Installing the OMB Cabinet
Installing the OMB Cabinet on a Wall
a
210mm
378mm
210mm
378mm
Determine the position of the backplane on the wall, and
mark the four anchor points by using a marker.
Drill the holes and install the expansion bolt assembly.
55~60mm
90
φ14
3
4
5 6
20~30mm
Bolt M10x75
Spring washer 10
Plastic tube
Flat washer 10
Expansion bolt
NOTE
9
Install the backplane of the OMB frame on the wall.
Install the OMB frame on the backplane.
Installing the OMB Cabinet on a Pole
b
Install the first upper fastener assembly on the pole.
Flat washer
Spring washer
M10x180 bolt
Install the lower fastener assembly on the backplane.
M10x40 bolt
M6 screw
10
Install the backplane on the pole.
Install the mounting brackets for the OMB frame.
Install the OMB frame on the backplane.
11
Outdoor Pole-Mounting Scenario
1
Dedicated Outdoor Installation
Installing the RTN 905 in the OMB Cabinet (AC Power Supply)
a
Installing the RTN 905 in the OMB Cabinet (DC Power Supply)
b
This installation scenario applies to the RTN 905.
This installation scenario applies to the RTN 905.
NOTE
NOTE
12
Installing the Assemblies
1
Installing the RTN 905
The RTN 905 must be installed on the left
side of the surge-protection box (SLPU).
2
Installing the SLPU
The SLPU must be installed on the right side
of the RTN 905
Ground terminal
When installing the RTN 905, ensure that the
power module of the equipment is downward.
The RTN 905 can be installed inside
OMB cabinets in the same manner.
NOTE
13
1
Installing the PGND Cables
Installing the PGND Cables for the Cabinet
a
Cable installation is the same for
the RTN 905 installed inside DC
powered OMB cabinets.
When installing the PGND cables
in the DC powered OMB cabinet,
use the same method as that in
the AC powered OMB cabinet.
The ground cables and signal
cables must be bound separately
or must be separated from each
other for certain spacing to
minimize mutual interference.
The PGND cables are in yellow-
green color. The general ground
cable has a cross-sectional area
of 16 mm
2
.
Installing the PGND Cables for the RTN 905
b
Ground bar
NOTE
Installing and Routing the Cables
14
Installing the Input Power Cable for the OMB Cabinet (AC Power Supply)
a
a
b
b
a
N
PE
L
Installing the Input Power Cable for the RTN 905
b
2
NOTE
2
1
1
When installing power cables for the RTN 905, ensure that the power
cables are correctly connected to the positive and negative terminals of
the power distribution box.
2
Installing and Routing the Power Cables AC Power Supply
For AC OMB cabinets of Ver. C, connect the two power cables from
RTN 905 to any two power output terminals (such as terminals LOAD6
and LOAD7) with the maximum output current of 30 A. For information
about assembling the easy power receptacle (pressfit type) connector,
see "Appendixes ".
15
Installing the Input Power Cable for the OMB Cabinet
a
Installing the Input Power Cable for the RTN 905
b
RTN(
+)
NEG(-)
Ensure that the input
power cables of an OMB
cabinet are correctly
connected to the positive
and negative terminals of
the power distribution box.
1
2
1
When installing power cables for the RTN 905, ensure that the power
cables are correctly connected to the positive and negative terminals of
the DC power distribution box.
3
Installing and Routing the Power Cables DC Power Supply
For AC OMB cabinets of Ver. C, connect the two power cables from
RTN 905 to any two power output terminals (such as terminals LOAD6
and LOAD7) with the maximum output current of 30 A. For information
about assembling the easy power receptacle (pressfit type) connector,
see "Appendixes ".
16
INSIDE OUTSIDE
1~8
INSIDE OUTSIDE
4
Installing the Service Cables for the Equipment AC Power
Supply
Installing E1 Cables
a
Installing Ethernet Cables
b
Rubber block
FE0
OUTSIDE
UFLP
INSIDE
FE1
FE0
FE1
FE0
OUTSIDE
UFLP
INSIDE
FE1 FE0 FE1
Rubber block
E1 cables for 1xAnea
96/4xDB25 conversion
are used.
17
Installing IF Cables
c
Installing Fibers
d
Rubber block
Insulation tube
Binding strap
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Huawei OptiX RTN 905 Quick Installation Manual

Type
Quick Installation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI