CAME AGT is a single LED intercom internal audio receiver that can be installed at an appropriate height for the user. The device has a door lock release button and two auxiliary buttons. The ringtone volume can be set with key presses to off, low, medium, or maximum volume. The device has terminals for call from entry panel input, audio from entry panel, audio to entry panel, auxiliary services, and power supply. The device can be programmed to connect up to three internal receivers in parallel on the same call.

CAME AGT is a single LED intercom internal audio receiver that can be installed at an appropriate height for the user. The device has a door lock release button and two auxiliary buttons. The ringtone volume can be set with key presses to off, low, medium, or maximum volume. The device has terminals for call from entry panel input, audio from entry panel, audio to entry panel, auxiliary services, and power supply. The device can be programmed to connect up to three internal receivers in parallel on the same call.

AGTK200A03KHNA
HPC/1 + HNA
AGT A200K
A/200N
HA/200
AGT A200K + TARGHA + HNA KIT FA01559-EN
EN
E
n
g
l
i
sh
INSTALLATION MANUAL
AGT A200K
HA/200 A/200N
HBP HPC/1+HNA
Page 2 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
CONTENTS OF THE KIT
General precautions
Read the instructions carefully before staring installation and perform all procedures as explained by the manufacturer.
The installation, programming, commissioning and maintenance of the product must only be carried out by technicians who are
qualifi ed and properly trained in compliance with the regulations in force, including as regards health and safety, and disposal of
packaging.
The installer must ensure that the information for the user, where there is any, is provided and delivered.
Before carrying out any cleaning or maintenance, disconnect the devices from the power supply.
The equipment must only be used for the purpose for which it was expressly designed.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
Only use soft, dry or slightly damp cloths to clean the device. Do not use any chemical products.
These instructions must be attached to the device.
This product complies with current applicable reference standards.
DISPOSAL - Dispose of the packaging and the device at the end of its life cycle responsibly, in compliance with the laws in force
in the country in which the product is used. The recyclable components are marked with a symbol and the material ID marker.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE. THE MEASUREMENTS,
UNLESS OTHERWISE STATED, ARE IN MILLIMETRES.
M1
SW11
EXT.AUX 1
LED
P. B . SW12
M1
SW11
Page 3 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
AGT A200K
Description
Intercom internal audio receiver.
Function of terminals and jumpers
Terminal board M1
5Earth
7Call from entry panel input
8Audio FROM entry panel
9Audio TO entry panel
10
AUX2: auxiliary services (24V 100 mA)
11
21 +11 to 175 VDC LED power supply
22
AUX 1 (24V 100mA)
23
24 AUX1 LED (active to earth with SW12 jumper in position
EXT.)
Function of SW11 jumper
Remove the jumper to make the door lock release button ( )
active only with the handset raised.
Function of SW12 jumper
EXT.: LED connected to terminal 24.
P.B.: LED connected to AUX1 key.
Technical data
Type AGT A200 K
Single LED consumption (mA) 1
Operating temperature (°C) +5 to +40
Storage temperature (°C) -25 to +70
IP Rating IP30
503 503
Ø60
Page 4 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Installation
Open the device by pressing on the tab at the bottom .
Separate the shell from the bottom of the device.
Fasten the bottom of the device to the box on the wall
.
Avoid overtightening the screws.
the box must be installed at an appropriate height for the
user.
Once all connections have been made, reattach the shell to
the bottom of the device .
Ringtone settings
O (red LED on)
Where there is no power to terminal 21, the
volume switches from O to Low.
Medium volume
Maximum volume
Button functions
Door lock release
AUX 1
AUX 2
64,5
105
145
43,5
45
7,5 57
105
106
Page 5 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
A/200N
Description
A/200N guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 dual-tone call beeps for two entry panels (or for additional
call, e.g. from the landing).
- Power supply and control for solenoid lock (12 V AC, 1 A) via
a relay (inside the device) controlled by a timer, adjustable from
2 to 15 seconds using the potentiometer P1 .
- Call generator: 2 types of dual-tone beep (up to 3 internal
receivers can be connected in parallel on the same call). The
device can be powered at 12 V DC, for example by a battery or
UPS (terminals +B and 5).
The equipment does not include a battery protection device.
Function of terminals and jumpers
Terminal board A
Network
Terminal board B
+B Input 12 V DC (*)
5 Earth
21 Output 11 V DC
8 Common call output 1
8A Common call output 2
11 Audio from entry panel
12 Audio to entry panel
23 Output 14 V AC
16 +
NO Normally open
relay contactsC Common
NC Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C
5 Earth
8 Audio to internal receiver
9 Audio to internal receiver
Technical data
Type A/200N
50-60 Hz (VAC) power supply 230
Power consumption (VA) 34
Output voltages at 11 VDC (mA) 150
Output voltages at 14 VAC (mA) 650
Peak output voltages (mA) 300
Operating output voltages (mA) 650 (1A)
Storage temperature (°C) -25 to +70
Operating temperature (°C) 0 to +35
IP Rating IP30
1
2
3
Page 6 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
HA/200
Trimmers
Speaker audio
Microphone audio
Technical data
Type HA/200
Power supply (VDC) 12
Max power consumption (mA) 50
Power consumption in stand-by (mA) <35
Storage temperature (°C) -25 to +70
Operating temperature (°C) -15 to +50
IP Rating IP54
Installation
The device can be installed on DIN rails (EN 50022) on a
suitable switchboard, or on the wall using the terminal covers.
To dismantle the device, proceed as shown in fi gure 2-3.
See fi gure 1 for dimensions.
The power supply must always be installed horizontally.
Ensure there is correct ventilation if the power supply is
installed in a metal case.
Description
Audio module.
Functions of terminals and audio adjusters
Terminal board
5 power supply
21 + 12 VDC
8 common call (for call beep)
11 audio to internal receiver
12 audio from internal receiver
14 enable
In systems in which there is an enable command, terminal
14 can be connected to the earth (unit always active) or to
terminal 12 (unit active only when handset is raised).
A B C
1
HNA/102
Description
Access control module equipped with 2 relays that can be acti-
vated by codes keyed in on keypad.
Function of terminals and link
Terminal board M1
12÷16 VAC, 14÷18 VDC Power supply input
I1 En-
trance Entry panel contact
Ground
Terminal board M2
C1 Common
Relay contact 1NC Normally closed contact
NO Normally open contact
C2 Common
Relay contact 2NC Normally closed contact
NO Normally open contact
Function of SW1 link
Armed: Button illumination on.
Disarmed: Button illumination NOT on (default).
Technical data
Type HNA/102
Power supply (VAC) 12÷16
Consumption with AC power supply (mA) 260 max
Consumption in stand-by mode
with AC power supply (mA) 120
Power supply (VDC) 14÷18
Consumption with DC power supply (mA) 180 max
Consumption in stand-by mode
with DC power supply (mA) 80
Operating temperature (°C) 0 ÷ +35
Available functions
a) Up to 100 user codes can be stored. The codes can be of 3,
4 or 5 fi gures, with a value from 001 to 65535. Each code can
be associated to one of the 2 relays.
b) The module is equipped with 2 relays for services with the
following operating features:
- Programmable activation time for each relay (from 1 to 65
seconds);
- Monostable or bistable operation for each relay;
- Option to lock in active status the relays in monostable opera-
tion, by pressing the key before the activation time runs out
(to deactivate it re-enter the same code); relay 2 can if neces-
sary be associated to an alarm or bell activation service (by fi rst
enabling function 09).
Activation of the alarm
Relay 2 is activated by pressing before the user code (to
deactivate it see function 10).
All the user codes associated to relay 1 are enabled upon ac-
tivation of the alarm.
Activation of the bell
Relay 2 is activated only by pressing . In order to avoid the
alarm signal being sent inadvertently, the option to associate
user codes to relay 2 is automatically blocked.
c) When a key is pressed, beeps are generated to confi rm the
di erent programming stages, in the following ways:
- Key pressed = short beep;
- Correct operation = long beep;
- Incorrect operation = three short beeps.
d) The status of the module and the functions in progress are
shown with LEDs :
- green LED A can be programmed to be:
Light signal linked to beep.
Disabled.
Commanded by input I1.
- yellow LED B,
Pulsing = confi rmation of activation of services.
Page 7 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
- green LED C,
Always on = in operation,
Flashing = being programmed.
The LEDs light up 1 min after the equipment is powered up
(within which it is possible to carry out a reset of the equip-
ment).
e) It is possible to disable the keypad for an indeterminate time
using a special code, e.g. for prolonged absences (see function
12).
f) The keypad is locked for a time that can be programmed if a
valid code has not been entered after 20 fi gures are keyed in
(see function 07).
g) There is an input I1 for an electrical contact with a program-
mable function to activate relay 1, enable Tradesman function,
or command the green LED A (see function 11).
h) Tradesman: this function allows relay 1 to be enabled only
when contact I1 is grounded (with external timer) and only for
user codes associated to service 3 (see function 03).
i) The default confi guration values can be restored
using the RESET function (see reset procedure).
The stored user codes and the number of fi gures programmed
are retained.
Default values with which the module is provided
Programming code: (5 fi gures).
Reset code: not programmable;
User code on relay 1: .
User code on relay 2: .
Activation time for service relays: 5 seconds.
Activation type for service relays: monostable.
Number of fi gures for user codes: 4.
Keypad locking time: 10 seconds.
Bell: disabled.
Bell duration: 3 seconds.
Alarm: disabled.
Keypad: enabled.
Input for contact I1: command from relay 1.
Green LED A: disabled.
Programming procedure
Function programming sequence.
1. To enter programming mode, press keys 1 and 3 at the
same time. Key in the PROGRAMMING CODE (default
12345), the green LED C will fl ash.
2. Key in the FUNCTION CODE required (see list of function
codes).
To change the function code selected, press button or
and select a new function code.
3. Key in the required data.
A long beep indicates that the data has been recorded.
Three short beeps indicate an error.
4. After entering the data required a new function code can be
selected or the programming mode terminated by entering
99 (the green LED C stops fl ashing).
List of function codes
After accessing programming mode (green LED C fl ashing),
enter the desired function code:
FUNCTION CODE
Changing programming code (default 12345).
- Key in the new PROGRAMMING CODE (5 fi gures).
FUNCTION CODE
Changing number of fi gures in user code (default 4).
All the user codes have the same number of fi gures.
- Key in the NUMBER OF FIGURES (3 or 4 or 5).
FUNCTION CODE
Adding a user code
(default relay 1=2580, relay 2=3690).
- Key in the number of the SERVICE to be programmed (1 or
2 or 3):
= activation of relay 1,
= activation of relay 2,
= activation of relay 1 in Tradesman operation (see function
11).
- Key in the USER CODE (3 or 4 or 5 fi gures).
- Repeat the procedure to enter a new user code.
FUNCTION CODE
Deleting a user code.
- Key in the USER CODE to be deleted.
FUNCTION CODE
Deleting all user codes.
- Key in (USER CODE DELETION).
FUNCTION CODE
Setting service relays activation time (default 5 s).
- Select the desired RELAY by pressing or .
- Key in the ACTIVATION TIME from to seconds.
- Repeat the procedure to set the activation time of the other
relay.
FUNCTION CODE
Setting the keypad locking time, resulting from repeatedly
entering non-existent codes (default 10 s)
- Key in the LOCKING TIME from to seconds.
FUNCTION CODE
Setting monostable or bistable mode of relays (default mon-
ostable)
- Key in the desired SERVICE/RELAY.
= activation of relay 1,
= activation of relay 2,
= activation of relay 1 in Tradesman operation.
- Key in TYPE OF ACTIVATION
= BISTABLE
= MONOSTABLE
- Repeat the procedure to set another service/relay.
Page 8 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
FUNCTION CODE
Enabling/disabling alarm and bell (default disabled)
- Key in the mode:
= DISABLED
= ALARM ENABLED
= BELL ENABLED
NOTE. Enabling the alarm or the bell disables the settings
of relay 2.
FUNCTION CODE
Reset alarm
FUNCTION CODE
Programming input I1 (default command relay 1).
- Key in:
= Command relay 1
= Enable Tradesman
= Command green LED A
= Disabled
FUNCTION CODE
Enabling/disabling keypad (default enabled).
- Key in:
= Disabled
= Enabled
FUNCTION CODE
Programming green LED A
- Key in:
= Disabled
= Access by pressing any button
Note. Programming is not possible if the LED is already
associated to input I1 (see function 11).
Reset procedure
- Cut power to the device.
- Repower the device again (green LED C o ).
- Key in the RESET CODE within 1 min from switch-on.
Note. The stored user codes and the number of fi gures pro-
grammed are retained.
521 811 12 14
521 811 12 14
Page 9 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Wall-mounted installation
Fix the two hole covers to the base .
Attach the recessed box (with 3 modules
or round Ø 65 mm) fl ush with the wall
and at a suitable height; fi x the base to
the wall using the screws and expansion
plugs provided .
In systems where the Larsen e ect
might occur, the microphone can be
mounted remotely .
To remove the microphone from its
housing, pry it o its base using a
small screwdriver, taking care not to
damage the cabling .
Before inserting the microphone in the
bottom part of the back-box, use pliers
to remove the part that is highlighted .
Insert the audio unit near the top of the
base .
Apply the micro-contact (bottom high) in
the relevant seat . Perform the wiring.
Insert the HNA/102 access control mod-
ule at the bottom and fasten it using the
screw provided .
521 811 12 14
521 811 12 14
Button assembly
To write the desired information on the name card, take out
the card holder and the card. Personalised name cards up to a
maximum of 2 mm thick can be used.
Closing the front plate
To fi t the front plate, fi rst insert the upper part into the top and
then, using a 2.5 hex key, tighten the locking screw.
521 811 12 14
Page 10 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Wall mounting side by side
To mount the entry panels side by side horizontally, insert two hole covers into the exposed sides, and inside, the cable gland joint
at the bottom and the joint at the top .
Attach the assembled bases to the wall, using the screws and expansion plugs provided .
Page 11 - Manual FA01425-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
TARGHA 200
Accessories
HTS
Recess-mounting box
Frame
Cable gland joints
Spacer
Screws
KHPS
Button
Microcontact
Button spring
KHPD
Buttons
Microcontacts
Button springs
HBP
Wall-mounted base
Hole cover
Cable gland joint
Joint
Screws and expansion plugs
HPP/6 – HPP/12D
Front plate
Microcontacts with
common call
Lighting assembly
Cable holders
Hole cover
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 12 - Manual FA01559-EN - 02/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME AGT Installation guide

Category
Security access control systems
Type
Installation guide

CAME AGT is a single LED intercom internal audio receiver that can be installed at an appropriate height for the user. The device has a door lock release button and two auxiliary buttons. The ringtone volume can be set with key presses to off, low, medium, or maximum volume. The device has terminals for call from entry panel input, audio from entry panel, audio to entry panel, auxiliary services, and power supply. The device can be programmed to connect up to three internal receivers in parallel on the same call.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI