CAME AGATA KIT C200 Installation guide

Category
Telephones
Type
Installation guide
LVC/01
Agata Kit C200
Agata Kit C200
INSTALLATION MANUAL
AGK200C03UK – AG2K200C03UK
AGATAK200C03E – AGATAK200CB03
AGATA2K200CB03
FB00970-EN
EN
English
AGATA C/200
HA/200
A/200R
HBP
HPC/1
AGK200C03
HPC/2
AG2K200C03
HTS HPC/1
AGATAK200C03E
AGATA C/200
HA/200
A/200R
HBP
HPC/1
AGATAK200CB03
HPC/2
AGATA2K200CB03
Page 2 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
COMPOSITION OF KITS
102
39
190
1
5789
M1
BP1
P1
Page 3 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
General Precautions
Read the instructions carefully before beginning the installation and carry out the actions as specified by the manufacturer,
The installation, programming, commissioning and maintenance of the product must be carried out only by qualified technical
personnel, correctly trained with regard to respecting the regulations in force, including the implementation of accident prevention
measures and the disposal of packaging,
The installer must ensure that the information for the user, where there is any, is provided and delivered,
Before carrying out any cleaning or maintenance operation, disconnect the devices from the power supply,
The equipment must only be used for the purpose for which it was expressly designed,
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
Only use soft, dry or slightly damp cloths to clean the terminal; do not use any chemical products.
These instructions must be attached to the equipment.
The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the device properly at the end of its life cycle, according to the regu-
lations in force in the country where the product is used. The recyclable components bear the symbol and code for the material.
THE DATA AND INFORMATION PROVIDED IN THIS MANUAL ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT PRIOR NOTICE. MEASUREMENTS,
UNLESS OTHERWISE INDICATED, ARE IN MILLIMETRES.
AGATA C 200 – AGATA C/B 200
Agata C 200 Description
Internal audio receiver.
Door lock release button
Auxiliary Command 2 (Optional)
Function of terminals and links
Terminal board M1 1
5 - Ground
7 - Call from entry panel input
8 - Audio FROM entry panel
9 - Audio TO entry panel
BP1 1
Remove the link to wire BP1 to make the door lock release but-
ton ( ) active only with handset raised.
P1 1
Housing for insertion of optional button for auxiliary services
( ) AGATA P1.
Technical data
Type Agata C200
Operating temperature (°C) +5 ÷ +40
Storage temperature (°C) -25 ÷ +70
IP Rating IP 30
5
7
8
9
E
10
11
12
13
14
15
16
14A
15A
16A
17
20
21
14A
15A
16A
17
20
21
5
7
8
9
E
10
11
12
13
14
15
16
M1
M2
SW10
STD
SW11
INT
SW11
STD
INT
STD
INT
A
B
102
39
190
2
Page 4 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Agata C/B 200 Description
Intercom internal audio receiver.
Function of terminals and links
Terminal board M1 2
5Ground
7Call from entry panel input
8Audio FROM entry panel
9Audio TO entry panel
EEnable audio*
*Connection reserved for the creation of special systems (mixed
audio and video entry phone systems).
10
AUX: auxiliary services (24V 100 mA)
11
12 Call from entry panel output
13 Common intercom call
14 Call to internal receiver no. 1
15 Call to internal receiver no. 2
16 Call to internal receiver no. 3
Terminal board M2 2
14A Call to internal receiver no. 4
15A Call to internal receiver no. 5
16A Call to internal receiver no. 6
17 +11÷17.5 VDC power supply (green LED)
20 Doorbell input
21 +11÷17.5 VDC power supply (red LED)
Function of SW 11 link 2
Remove the link to make the door lock release button ( )
active only with handset raised.
Function of SW 10 link 2
Call privacy disabled. Intercom possible by adding a
VSE/200 to the system.
Call privacy enabled. The system must include a VA/200 or
an A/200R + GS/200.
Technical data
Type Agata C/B 200
Individual consumption (mA) 1
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) +5 ÷ +40
IP Rating IP30
503
43
Ø60
5
6
Page 5 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Installation of Agata C 200 - Agata C/B 200
Open the device by pressing on the lever at the bottom 3.
Separate the shell from the bottom of the device.
Secure the bottom of the device to the wall mounting using the screws provided
45.
Avoid tightening the screws too much.
The box must be installed at an appropriate height for the user.
Once all connections have been made, reattach the shell to the bottom of the
device 6.
Int. 1
Int. 1
Int. 2
Int. 2
Int. 2
Int. 1
Int. 1 Int. 2
2
2
Int. 1
Int. 1
8
7
Page 6 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Function of buttons
Door lock release
Auxiliary 2
Intercom buttons 1÷5
Intercom 6 (green LED = line busy)
Adjustment of ringtone
0 = disabled (red LED)
I = Average volume
II = Maximum volume
Intercom 7
To call an internal receiver, pick up the handset and press the
button for the receiver you want.
Call transfer 8
When an active call is open, select the internal receiver to which
the call is to be transferred. As soon as the internal receiver
which has been called picks up the handset, the call is active
between the two receivers; the entry panel remains on hold.
To connect internal receiver 2 with the entry panel, internal re-
ceiver 1 and subsequently internal receiver 2, must replace the
handset and then internal receiver 2 must pick it up.
Where the call is not successfully transferred, replace the hand-
set and pick it up again to reactivate audio communication with
the entry panel.
1
43,5
45
7,5 57
70
106
A
B
64,5
70
145
43,5
45
7,5 57
70
106
A
B
64,5
70
145
Page 7 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
A/200R
Description
A/200R guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 two-tone call notes for two entry panels (or for additional
call, e.g. from front door).
- Power supply and control for solenoid lock (12 Vac 1 A) via a
relay (inside the equipment).
- Call generator: 2 types of two-tone notes (up to 3 internal
receivers can be connected in parallel on the same call). The
equipment can be powered at 12 VDC, for example by a battery
or continuity group (terminals +B and 5).
The equipment does not include a battery protection device.
Function of terminals and links
Terminal Board A 1
Network
Terminal Board B 1
+B 12 VDC input (*)
5 Ground
21 11 VDC output
8 Common call output 1
8A Common call output 2
11 Audio from entry panel
12 Audio to entry panel
23 14 Vac output
16 +
NO Normally open
relay contactsC Common
NC Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal Board C 1
5 Ground
8 Audio to internal receiver
9 Audio to internal receiver
Technical data
Type A/200R
50÷60 Hz (Vac) power supply 230
Power consumption (VA) 34
Output voltages at 11 VDC (mA) 150
Output voltages at 14 VAC (mA) 650
Peak output voltages (mA) 300
Operating output voltages (mA) 650 (1A)
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) 0 ÷ +35
IP Rating IP30
1
2
3
2 3
1
Page 8 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Installation
The equipment can be installed on DIN rails (EN 50022) on a
suitable switchboard or on the wall using the terminal covers.
To dismantle it, proceed as shown in figure 2 3.
For the size of the footprint see figure 1.
The power supply must ALWAYS be installed horizontally.
Ensure there is correct ventilation if the power supply is
installed in a metal case.
HA/200
Description
Audio module.
Functions of terminals and audio adjusters
Terminal Board 1
5 power supply
21 + 12 VDC
8 common call (call transfer tone)
11 audio to internal receiver
12 audio from internal receiver
14 enabling
In systems in which an enabling command is provided, ter-
minal 14 can be connected to the ground (group always ac-
tive) or to terminal 12 (group active only when handset is
raised).
Adjusters (trimmers) 1
Speaker audio
Microphone audio
Technical data
Type HA/200
Power supply [VDC] 12
Max power consumption (mA) 50
Power consumption in stand-by (mA) <35
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) -15 ÷ +50
IP Rating IP54
Page 9 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
TARGHA 200
Accessories
HTS
Recessed box
Back-box
Cable gland joints
Spacer
Screws
KHPS
Button
Microcontact
Button spring
KHPD
Buttons
Microcontacts
Button springs
HBP
Wall-mounted base
Blanking plug
Cable gland joint
Joint
Screws and expansion plugs
HPP/6 – HPP/12D
Front plate
Microcontacts with
common call
Lighting group
Cable holders
Blanking plug
521 811 12 14
521 811 12 14
521 811 12 14
521 811 12 14
1 2
3
4
6
5
7
Page 10 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Recessed installation
The HTS recessed box must be walled in
flush with the wall at a suitable height, us-
ing the spacer provided in order to avoid any
distortion of the box 1.
In systems where the Larsen eect might
occur, the microphone can be mounted re-
motely 4.
To remove the microphone from its
housing, pry it o its base using a small
screwdriver, taking care not to damage
the cabling 2.
Before inserting the microphone into the bot-
tom of the back-box, use pliers to remove the
part that is highlighted 3.
Insert the audio group high up, near to the top of the back-box
4.
Fit the microcontact (bottom right) into the correct housing 5.
The front plate is equipped with a common call for the
microcontacts, to be used when other buttons are to be
installed (maximum of 4) 6.
Insert the lighting group in the relevant housing 7.
Remove the two protective seals on the holes in the recessed
box and attach the back-box using the two screws provided 8.
Make the connections and secure the cables using the cable
holder 9.
The cable holder must be located near to the audio group.
521 811 12 14
521 811 12 14
8 9
Page 11 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
521 811 12 14
521 811 12 14
521 811 12 14
521 811 12 14
5 76
4
1
521 811 12 14
3
2
Page 12 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Wall mounting
Fix the two blanking plugs to the base
1.
Attach the recessed box (with 3 modules
or round Ø 65 mm) flush with the wall
and at a suitable height; fix the base to
the wall using the screws and expansion
plugs provided 2.
In systems where the Larsen eect
might occur, the microphone can be
mounted remotely 4.
To remove the microphone from its
housing, pry it o its base using a
small screwdriver, taking care not to
damage the cabling 3.
Before inserting the microphone into the
bottom of the back-box, use pliers to
remove the part that is highlighted 4.
Insert the audio group high up, near to
the top of the base 4.
Fit the microcontact (bottom right) into
the correct housing 5. The front plate
is equipped with a common call for
the microcontacts, to be used when
other buttons are to be installed
(maximum of 4) 6.
Insert the lighting group in the relevant
housing 7.
Make the connections and secure the
cables using the cable holder 7.
The cable holder must be located near
to the audio group.
521 811 12 14
521 811 12 14
21
1
Page 13 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Button assembly
To write the desired information on the name card, take out the
card holder and the card 1.
Personalised name cards up to a maximum thickness of 2 mm
can be used.
Closing the Front Plate
To assemble the front plate first insert
the upper part into the top and then,
with a 2.5 hex key, tighten the locking
screw 1 2.
1
4
3
2
Page 14 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Recessing side by side
To recess boxes side by side horizontally or vertically, remove
the blanking plugs and insert the cable gland joints 1 2.
The recessed boxes must be walled in flush with the wall at a
suitable height, using the spacers provided in order to avoid any
distortion of the box 3 4.
1
2
Page 15 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Wall mounting side by side
To mount the entry panels side by side horizontally, insert two
blanking plugs into the exposed sides, and inside, the cable
gland joint at the bottom and the joint at the top 1.
Attach the assembled bases to the wall, using the screws and
expansion plugs provided 2.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FB00970-EN - vers. 1 - 10/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME AGATA KIT C200 Installation guide

Category
Telephones
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI