43,5
45
7,5 57
70
106
A
B
64,5
70
145
43,5
45
7,5 57
70
1
Page 6 - Manual FA01430-EN - 10/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
A/200R
Description
A/200R guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 dual-tone call beeps for two entry panels (or for additional
call, e.g. from the landing).
- Power supply and control for solenoid lock (12VAC 1A) via a
relay (inside the device).
- Call generator: 2 types of dual-tone beep (up to 3 internal
receivers can be connected in parallel on the same call). The
device can be powered at 12 V DC, for example using a battery
or inverter (terminals +B and 5).
The equipment does not include a battery protection device.
Function of terminals and jumpers
Terminal board A 1
Network
Terminal board B 1
+B Input 12 V DC (*)
5 Earth
21 Output 11 V DC
8 Common call output 1
8A Common call output 2
11 Audio from entry panel
12 Audio to entry panel
23 – Output 14 V AC
16 +
NO Normally open
relay contacts
C Common
NC Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C 1
5 Earth
8 Audio to internal receiver
9 Audio to internal receiver
Technical data
Type A/200R
Power supply 50-60 Hz (V AC) 220-230
Power consumption (VA) 34
Output voltages at 11 VDC (mA) 150
Output voltages at 14 VAC (mA) 650
Peak output voltages (mA) 300
Operating output voltages (mA) 650 (1A)
Storage temperature (°C) -25 to +70
Operating temperature (°C) 0 to +35
IP Rating IP30