Installation Instructions
Occupant Copy
Please read before installing.
CAUTION
!
Lutron recommends that Keypads be installed by a qualified electrician.
Do not connect high-voltage power to low-voltage terminals. Improper wiring can result in personal injury or damage to
the control or to other equipment.
Keypads must be connected to the Sivoia QEDTM Electronic Drive Unit (EDU) by using Class 2 (USA)/ PELV(IEC) wiring
methods. Check with your local electrical inspector for the local code requirements and wiring practices
allowed in your area.
Use only a cloth with warm water and mild soap to clean faceplates (no chemical cleaners).
Keypad Configurations
Status Indicator
LEDs
Raise button
Lower button
Preset button
Close button
Raise/Lower
Status Indicator
LEDs
Preset button
Close button
1
2
3
Open button
Status Indicator
LEDs
Group Selection
LEDs
Preset button
Close button
Group 1 button
Group 2 button
Group 3 button
Button Functionality
Tap the Open, Close, or Preset button to move the window
treatments to the selected position. While pressing the Raise or
Lower button, the window treatments will raise or lower.
Numbers - Tapping one of the numbered buttons
will select a group of EDUs to control.
Open - Tap the open button to move the window
treatments to the fully-open position.
Preset - Tap the preset button to move the window
treatments to their programmed preset level.
Close - Tap the close button to move the window
treatments to the fully-closed position.
Raise - Holding the raise button will move the
window treatments towards the open position.
Releasing the raise button will cause the window
treatments to stop.
Lower - Holding the lower button will move the
window treatments towards the closed position.
Releasing the lower button will cause the window
treatments to stop.
Note: Holding the or buttons for 5 seconds
will cause the window treatments to move all the
way open or closed automatically.
3Occupant Copy Installation Instructions
Wiring Notes
System Maximums:
Up to 96 devices total on one system.
One transformer per EDU.
The Keypads wire to the Sivoia QED Communication
Link. The Link can not exceed 1220 m (4000 ft) total.
The Keypads are either powered by EDUs or Keypad
Power Supplies. Each EDU can provide power for one
Keypad.
The number of Keypads should not exceed
the number of EDUs unless connecting with a Keypad
Power Supply.
The maximum distance between any two Sivoia QED
devices is 305 m (1000 ft) unless specified otherwise.
Operating environment should be between 0 °C -
40 °C (32 °F - 104 °F).
Keypad Wiring
Two 1.0 mm
2
(#18 AWG) wires for power and two
shielded 1.0 mm
2
(#18 AWG) stranded wires for data
(twisted pair).
Power: wires 1 & 2, 12 - 15 V .
Data: wires 3 & 4, twisted, shielded pair.
Sivoia QED Link wiring layouts are shown on the next
page.
1, 2, 3
4
Sivoia QED Link:
Class 2/PELV Wiring
connections to EDUs,
Power Panels, or
other Keypads.
Male EDU Connector
Sivoia QED Keypad Wiring
Installation Instructions Occupant Copy4
4. Each Keypad terminal will accept up to two 1.0 mm
2
(#18 AWG) wires.
Connect two 1.0 mm
2
(#18 AWG) wires to terminals 1 and
2 of the Keypad’s terminal block.
Connect two 1.0 mm
2
(#18 AWG) shielded, twisted pair
wires to terminals 3 and 4 of the Keypad’s terminal block.
1
2
3
4
Common
12V
MUX
MUX
AC1
AC2
EGND
Female EDU
Connector
Sivoia QED EDU
Back of
Sivoia QED Keypad
Installation
Keypad circuits are classified as Class 2 circuits (U.S.A.) and
PELV circuits (IEC). When installing and wiring to these
Keypads, follow all applicable national and/or local wiring
regulations.
Warning: Always turn Off the circuit breaker or
remove the main fuse from the power line before
doing any work.
Failure to do so can result in
serious personal injury
.
1. Turn power Off to all EDUs and power panels.
2. Mount standard German or UK backboxes (60 mm
measured centre to centre of mounting holes).
3. Strip insulation from wires so that 10 mm. (3/8 in) of bare
wire is exposed for 1.0 mm
2
(#18 AWG) wire.
ON
OFF
ON
OFF
ON
OFF
10 mm (3/8 in.)
5Occupant Copy Installation Instructions
5. Remove the faceplate from the Keypad. To remove the
faceplate, pull outward at each corner, one corner at a
time.
6. Mount Keypad as shown in the diagram below.
7. Attach faceplate by pressing in at each corner, one corner
at a time.
Thread all four screws before tightening.
Wallbox
Wall
Mounting Frame Orientation
Wallbox
Mounting
Frame
Carrier Faceplate
Mounting
Frame
Addressing the System
Note: For the SQE-RL, use the and buttons instead of
the and buttons.
1. Enter programming mode on the Keypad by pressing and
holding the Open ( ) and Close ( ) buttons
simultaneously for 5 seconds. The LEDs next to the Open
( ) and Close ( ) buttons will flash once per second,
indicating the Keypad is in Programming mode.
2. Initiate system addressing by tapping the Open ( ) button.
The LED next to the Open ( ) button will flash quickly (8
times a second) and the LED next to the Close ( ) button
will turn off. The system is now being automatically
addressed.
Press the Open ( ) and
Close ( ) buttons
simultaneously for 5
seconds.
Flashing
once per
second
3. Wait for system addressing to be completed. This will take
approximately one minute. While addressing is in progress,
each Keypad will flash the Open ( ) LED quickly (8 times
a second). When addressing has successfully completed,
the Open ( ) and Close ( ) LEDs on each Keypad in the
system will flash slowly (once per second).
4. When system addressing is complete, exit Programming
mode by pressing and holding the Open ( ) and Close
( ) buttons simultaneously for 5 seconds. The Open ( )
and Close ( ) LEDs will stop flashing.
Tap the Open ( )
button.
Flashing 8
times per
second
4. Adjust the currently selected EDU to the desired level,
using the Raise ( ) and Lower ( ) buttons on the
Keypad.
6
Setting Limits
Note: Entering Limit Setup mode may cause the
window treatments to move approximately 200 mm
(8 in) up or down.
Be sure that each window
treatment is positioned such that the fabric can safely
move approximately 200 mm (8 in) before entering
Limit Setup mode.
Note:
When using Keypads that do not have Raise and Lower
buttons, set the limits at the EDU. Refer to the
Sivoia QED
Wiring and Programming Guide for more information.
1. If using the SQE-33, select the group you wish to assign.
2. Enter Limit Setup mode by pressing and holding the Open
( ) and Raise ( ) buttons simultaneously for 5 seconds.
The LED next to the Open ( ) button will flash once per
second and the LED next to the Close ( ) button will flash
quickly (8 times per second).
3. Select the EDU to adjust using the Open ( ) button on the
Keypad. Each time the Open ( ) button is tapped, an EDU
will begin opening and closing over a range of
approximately 200 mm (8 in). Repeat tapping the Open ( )
button until the desired EDU is selected. The Close ( )
button can also be used to select EDUs by moving through
the EDUs in the opposite order.
5. Store the current position as the Open ( ) limit by
pressing and holding the Open ( ) button on the Keypad
for 5 seconds. The LED next to the Open ( ) button will
turn on for two seconds.
OR
Store the current position as the Close ( ) limit by
pressing and holding the Close ( ) button on the Keypad
for 5 seconds. The LED next to the Close ( ) button will
turn on for two seconds.
6. Use the Open ( ) or Close ( ) buttons to select other
window treatments and adjust the limits as in Steps 3 and
4.
7. Exit Limit Set mode by pressing and holding the Open ( )
and Raise ( ) buttons simultaneously for 5 seconds.
Installation Instructions Occupant Copy
LED on for 2
seconds
Press & hold
here to set the
Open ( ) limit
Press the Open ( )
and Raise ( ) buttons
simultaneously for 5
seconds.
LED flashing once
per second
LED flashing 8 times
per second
Press the Raise ( ) or
Lower ( ) button.
LED on for 2
seconds
Press & hold
here to set the
Close ( ) limit
7
7Occupant Copy Installation Instructions
EDU Assignment
Note: Entering Assignment mode will cause the
window treatments to move between their Open and
Close limits.
Be sure that the Open and Close
limits have been set appropriately.
Note:
For the SQE-RL, use the and buttons instead of
the and buttons.
1. If using the SQE-33, select the group you wish to assign.
2. Enter Programming mode on the Keypad by pressing and
holding the Open ( ) and Close ( ) buttons
simultaneously for 5 seconds. The LEDs next to the Open
( ) and Close ( ) buttons will flash once per second,
indicating the Keypad is in Programming mode.
3. Initiate Assignment mode by tapping the Close ( ) button.
The LED next to the Close ( ) button will continue to flash
(once per second) and the LED next to the Open ( )
button will turn off. EDUs that are assigned to the Keypad in
Assignment Mode will move to their Close limit. EDUs that
are not assigned to the Keypad will move to their Open
limit.
4. Tap any button on an EDU to toggle between assignment
or unassignment with the Keypad.
OR
Use the Open ( ) button to step through each EDU in the
system. Each time the Open ( ) button is tapped, a
window treatment will begin opening and closing over
approximately 200 mm (8 in). Repeat tapping the Open
( ) button until the desired EDU is selected. The Close
( ) button can also be used to select EDUs in the
opposite order.
5. Assign or unassign the currently selected EDU using the
Raise ( ) and Lower ( ) buttons. To assign, tap the
Lower ( ) button. To unassign, tap the Raise ( )
button.
6. Check assignment before exiting Assignment mode. EDUs
that are at the Close limit are assigned. EDUs that are at
the Open limit are unassigned.
7. Exit Assignment mode by pressing and holding the Open
( ) and Close ( ) button simultaneously for 5 seconds.
Each EDU will return to the level it was at when
Assignment mode was entered. The Open ( ) and Close
( ) LEDs will stop flashing.
Press the Open ( )
and Close ( )
buttons
simultaneously for 5
seconds.
Flashing
once per
second
Tap the Close ( )
button.
Flashing
once per
second
Tap the Raise ( )
or Lower ( )
button.
8
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036 U.S.A.
Made and printed in U.S.A.
P/N 040-227-12 Rev. A 1/05
Limited Warranty
Lutron EA Ltd. (“Lutron EA”) warrants each unit to be free from defects in material and
workmanship and to perform under normal use and service. To the extent permitted by law,
Lutron EA and Lutron Electronics Co. Inc. (“Lutron”) make no warranties or representations as
to the units except as set forth herein. This warranty shall run for a period of one year from the
date of purchase and Lutron’s obligations under this warranty are limited to remedying any
defect, replacing any defective part or replacement (at Lutron EAs sole option) and shall be
effective only if the defective unit is shipped to Lutron EA postage prepaid within 12 months
after purchase of the unit, to the extent permitted by law. Repair or replacement of the unit
does not affect the expiry date of the warranty.This warranty does not cover damage or
deficiencies due to abuse, misuse, inadequate wiring or insulation or use or installation other
than in accordance with instructions accompanying the unit.
Although every attempt is made to ensure that catalogue information is accurate and up-to-
da
te,
please check with Lutron EA bef
ore specifying or purchasing this equipment to confirm
availability, exact specifications, and suitability for your application.
This warranty does not affect the statutory rights of consumer purchasers of the unit.
These products may be covered by one or more of the following US patents: 4,835,343;
4,924,349; D422,567; D436,930; D453,742; D456,783; D461,782; D465,460; D465,770;
D466,090; D466,091; D466,484; D475,024; D475,025; and corresponding foreign patents.
US and foreign patents pending. Lutron, the Sunburst logo, and Sivoia are registered
trademarks, and Sivoia QED is a trademark of Lutron Electronics Co., Inc.
© 2005 Lutron Electronics Co.,
Inc.
Note: The current position is stored as a preset only on the
EDUs that are assigned to that preset button. The preset is only
accessable from that particular Keypad.
Troubleshooting
For information on troubleshooting, please refer to the Sivoia
QED
Wiring and Programming Guide.
Storing Presets
Sivoia QED EDUs have the ability to store positions as presets.
1. Set all EDUs controlled by the Keypad to the desired level
using the Raise ( ) and Lower ( ) buttons on the
Keypad.
2. Store the EDUs’ current position as a preset by pressing
and holding the desired Preset ( ) button for 5 seconds.
The LED next to the Preset button ( ) on the Keypad will
flash and then turn on, indicating that the preset has been
stored.
Technical Assistance
EUROPEAN HEADQUARTERS
Lutron EA Ltd.
6 Sovereign Close
London, E1W 3JF
United Kingdom
Tel: +44-(0)20-7702-0657
Fax: +44-(0)20-7480-6899
CUSTOMER SERVICE/ORDERING
UK +44-(0)20-7702-0657 –
09.00 - 18.00 GMT
USA +1-610-282-3800 –
08.00 - 20.00 EST
CUSTOMER SERVICE/E-MAIL
TECHNICAL SUPPORT & SERVICES
UK +44-(0)20-7702-065709.00 -
18.00 GMT
USA +1-610-282-3800 – 24 hours/7
days
INTERNET: www.lutron.com
WORLD HEADQUARTERS
Lutron Electronics Co.,
Inc.
7200 Suter Road
Coopersburg, PA 18036
United States
Tel: +1-610-282-3800
Fax:+1-610-282-1243
Press the Preset ( )
button for 5
seconds.
LED will
flash and
then turn
on.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Lutron Electronics SQE-2 User manual

Category
Numeric keypads
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI