Hubbell Wiring Device-Kellems HWS772036 INST HJU SERIES UTP JACK, HWS772036-INST HJU SERIES UTP JACK Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Hubbell Wiring Device-Kellems HWS772036 INST HJU SERIES UTP JACK Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Control No. Page of
Rev. Date:
®Hubbell Premise Wiring Instruction Sheet
Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
14 Lord's Hill Rd, Stonington CT 06378 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com
Control No. Page of
Rev. Date:
HJU Series UTP Jack Termination
Instructions
HWS77203601 1 2
4 4/13/20
HWS77203601 2 2
4 4/13/20
Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
23 Clara Dr Suite 103 Mystic, CT 06355 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com
Remove 1" (25mm) of jacket
from cable. (Figure 2)
Place wire manager
on cable. (Figure 1)
1
2
3
4
5
6
Figure 1 Figure 2
Trim wire separator from cable
and insert wires into the slots
in the wire manager based
on the desired color code.
(T568A/T568B) (Figure 3)
Figure 3
Figure 4
Figure 5
Trim wires ush to wire
manager. The wires should
not protrude more than
1/64" (.5mm) from wire
manager. (Figure 4)
Line up arrows on
wire manager with
arrows on jack.
Note: The brown
pair will always go
towards the Cobra
Lock. (Figure 5)
With wire manager in
place, rotate termination
jaws; the jaw opposite the
Cobra Lock should rotate
rst. (Figure 6)
Squeaze the termination jaws
closed until the Cobra Lock
latches engage to complete the
termination. (Figures 7, 8)
To disassemble the jack, place
a small at screw driver into
the slots and rotate to pry
open the Cobra Lock latches.
(Figure 9)
Cobra Lock
Arrow
located on
side with
brown pair.
Arrows
Figure 6
Figure 7 Figure 8
Figure 9
Note: Accepts
24 to 22 AWG
conductors. Max
cable diameter
.31" (8mm).
/