  • Hello, I'm a chat assistant that has read the Instruction Sheet for the Hubbell HJU Series UTP Jack. I understand it provides instructions on how to terminate UTP cables using the jack, including steps like removing the jacket, placing the wire manager, and using the Cobra Lock termination. I am ready to answer any questions you might have about the device or the instructions.
  • What size conductors does the jack accept?
    What is the maximum cable diameter?
    What color codes are supported?
    How do you disassemble the jack?
Control No. Page of
Rev. Date:
®Hubbell Premise Wiring Instruction Sheet
Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
14 Lord's Hill Rd, Stonington CT 06378 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com
Control No. Page of
Rev. Date:
HJU Series UTP Jack Termination
Instructions
HWS77203601 1 2
4 4/13/20
HWS77203601 2 2
4 4/13/20
Hubbell Premise Wiring, HUBBELL INCORPORATED (Delaware)
23 Clara Dr Suite 103 Mystic, CT 06355 (800) 626-0005, Fax (860) 535-8328
www.hubbell-premise.com
Remove 1" (25mm) of jacket
from cable. (Figure 2)
Place wire manager
on cable. (Figure 1)
1
2
3
4
5
6
Figure 1 Figure 2
Trim wire separator from cable
and insert wires into the slots
in the wire manager based
on the desired color code.
(T568A/T568B) (Figure 3)
Figure 3
Figure 4
Figure 5
Trim wires ush to wire
manager. The wires should
not protrude more than
1/64" (.5mm) from wire
manager. (Figure 4)
Line up arrows on
wire manager with
arrows on jack.
Note: The brown
pair will always go
towards the Cobra
Lock. (Figure 5)
With wire manager in
place, rotate termination
jaws; the jaw opposite the
Cobra Lock should rotate
rst. (Figure 6)
Squeaze the termination jaws
closed until the Cobra Lock
latches engage to complete the
termination. (Figures 7, 8)
To disassemble the jack, place
a small at screw driver into
the slots and rotate to pry
open the Cobra Lock latches.
(Figure 9)
Cobra Lock
Arrow
located on
side with
brown pair.
Arrows
Figure 6
Figure 7 Figure 8
Figure 9
Note: Accepts
24 to 22 AWG
conductors. Max
cable diameter
.31" (8mm).
/