Midmark Artizan® Sterilization Cabinetry - Streamline - SC120-200 Installation guide

Category
AV equipment stands
Type
Installation guide

Midmark Artizan® Sterilization Cabinetry - Streamline - SC120-200 offers a compact and efficient solution for dental practices seeking reliable sterilization and storage options. This free-standing unit combines advanced functionality with ergonomic design, providing ample space for essential equipment and supplies. The cabinetry is fully customizable, allowing you to tailor it to your specific workflow and space requirements.

Midmark Artizan® Sterilization Cabinetry - Streamline - SC120-200 offers a compact and efficient solution for dental practices seeking reliable sterilization and storage options. This free-standing unit combines advanced functionality with ergonomic design, providing ample space for essential equipment and supplies. The cabinetry is fully customizable, allowing you to tailor it to your specific workflow and space requirements.

General Information: Many Artizan Design Free-st anding Sterilization Centers are custom
designe d and b uilt to the customers spec ifications using our standard sterilization modules.
Follow these general instructions using your specific order drawings to properly erect your
sterilization center.
Customer Service and Technic al Support:
8:00 AM to 5:0 0 PM central (M-Th)
8:00 AM to 4:3 0 PM central (Fri)
Phone: 800-257-7407 or 270-651-7407
Fax: 270-651-1732
INSTALLATION AND CUSTOMER CARE
INFORMATION FOR SC120-2 00
FREESTANDING STERIL IZATION CENTE RS
INDEX
Upper Wall Cabinets
Base Cabinet s
Toe Kick
GENERAL DESCRIPTION OF CABINET SE CTIONS
WRAP DRAWER
WRAP DRAWER
5"
5"
5"
5"
5"
5"
Service Panel
Upper Wall Cabinets
Base Cabinet s
Service Panel
TABLE TOP
OR OPTIONAL
RECES SED
ULTRASONIC
AUTOCLAVE
STATIM
Sterilizer
Tower
9.00
9.00
11.00
TIMER
21" RECESSED
TASK LIGHT
21" RECESSED
TASK LIGHT
PAGE 3 Parts List
PAGE 4 Assembling the base cabinets
PAGE 5 Attaching side and back walls
PAGE 6 Installing upper ca binets
PAGE 7 Installing task lights and service panel
PAGE 8 Installing counter top and sink
PAGE 8 Assembling the sterilizer tower
PAGE 9 Installing toe-kick /
Locating wired circuits
PAGE 10 Finalizing Installation
PAGE 11 Solid su rface c are and maintenanc e
PAGE 12-16 Circuit diagrams
PAGE 17 Hardware a djustments
PAGE 18-22 Airglide™ part s and schematics
S C120-200
Free-standing S ter il ization
- PARTS LIST -
PAGE 3 OF 22
Note - Parts may vary according to cabinet configuration
Note - Parts NOT shown ac tual size
20 - Leg Levelers
SKU# H84 80
4 - #6 X 1 " Black Wood Screw
(Used fo r Top Install)
SKU# S19100
68 - 1/4- 2 0 X 1 1/4" Machine Screw
(Used fo r side walls and back panels)
SKU# S19151
16 - Connector Bolts
SKU# 1 9 074
16 - Euro Scre ws
(Located with slide out shelves)
SKU# 1 9 000
8 - #6 X 1 5/8" Black Wood Screw
(Used fo r Top Install)
SKU# S19102
85 - #8 X 3/4" Wood Screw
(Located with Hangrail)
SKU# S19106
6 - 5/8 Square Head Lights
SKU# 19015
CLAMPS
Free-standing Ster ilization
- Step #1 Assemb ling The Base cabinets -
LEVELING
ATTACHING CABINETS TOGETHER
USING CONNECTING SCREWS
2. Hold or clamp the front edges together
and using th e through holes located at
the top and botto m near the face of the
cabinets insert one end of the con necting
screw into the hole and tap lightly with a
hammer until seated against side wall.
Thread the oth e r end into the adjacent
hole an d tighten using a phillips tip in a
cordless screwgun or drill. Repeat with the
through holes near the rear of the cabinet.
INSTALLING LEG LEVELERS
1. Remove all doors and
drawers from cabinets.
Check the floor area with
a 4 foot level and determine
the amount of fall. Lay the
first cabinet on its back and
tap legs in with a hammer.
Pre-adjust legs to 5 1/8" -
5 1/4". Stand the first cabinet
and set upright. Repeat the
process with the next cabinet
and level it next to the first
cabinet.
Note - See page 17 for proper
drawer removal procedure.
3. Continue setting and leveling
cabinets using a 4 foot level.
Check the ent ire run of cabinets
after assembling. Make sure all
legs are touching the floor and
optimally are bearing an equal
portion of the weight.
Note - legs can be adju sted
either by turning from the
outside or by using
a narrow flat blade screwdriver
from inside the cabinet and
through the center of t he leg.
5 1/8" - 5 1/4"
Right Side View
Back of Cabinet
FLOOR
4. Assemble base cabinets together us ing the layout shown in your drawing.
PAGE 4 OF 22
1 1/4“ x 1/4” x #20
flathead machine
screws.
Note:
Back and side wall panels
are held toget he r at the top
end by the attachment of the
upper wall cabinets in the next
step.
Note:
Hang rails and kits are
located with the side
walls or c ounter tops.
Note:
Back panels rest onto
extended base cabinet
bottom panels.
3. Sec ure the back wall pane ls t ogether by attaching
the wall cabinet hang rail using 3/4" x #8 woo d screws
2. Att ach all back panels to base cabinets using
1 1/4“ x 1/4” x #20 flathead machine screws.
3/4" x #8 Wood Screws
Free-standing Ster ilization
- Step #2 Attachin g Side and Back Walls -
1. Att ach both of the side walls to the
base cabinets using 1 1/4 “ x 1/4” x #20
flathead machine screws.
Note - Side walls ov erlap the back of the
base cabinets by approximately 3/4".
PAGE 5 OF 22
CONTOURED
SIDE WALL
PANEL
PAGE 6 OF 22
INTERNAL ADJUSTMENT ARMS
2. Align cabinets together
using adjustme nt arms and
secure with co nnecting s crews
provided.
HANGING CABINETS
ATTACHING CABINETS T OGETHER
CLAMPS
1. Hang all uppers onto rail and
secure one end cabinet to side
wall using 1 1/4" flat head sc rews.
Important Note:
Install this upper
wall cabinet last.
1 Extend the ad justment arm
outward enough to easily catch
the top of the rail by turning the
bottom screw counterclockwise.
Adjustmen ts:
A - Top Screw - Up/Down
B - Bottom Screw - In/Out
Important Note:
Do not over-tighten adjustment
screws.
3. Hold or clamp the front edges together and using
the throu gh holes located at the top and bottom near
the face of th e cabinets inser t one end o f the con-
necting screw into the hole and tap lightly with a
hammer until seated against side wall. Thread t he
other end into the adjacent hole and tighten using a
phillips tip in a cordless screwgun or drill. Repeat
with the through holes near the rear of the cabinet.
A
B
Note:
Side walls may need
to be lo osened
slightly for easy
installa tion.
PAGE 7 OF 22
Wire Raceway
Mounts behind
tape dispenser
alcove.
3. Att ach task lights to bottom of wall cabinets
by using the 5 /8 square head screws.
2. Install service panel/s into notch on top
of bas e cabinets and snap into clips
mounted underneath upper wall cabinets.
Be sure to leave task lights in front of ser-
vice panels.
SERVICE PANEL
The Service Panel is
designe d to provide a
hidden chase for wires to
run behind cabinets.
1. Run task light wires downward into
the floor of the sink comp artment. DO
NOT attach task lights at this time.
PAGE 8 OF 22
1. Atta ch the countertop using 1 5/8“
screws for base cabinets with a wood
top pane l and 1” wood screws for
sink base cabinets with L-brackets.
Note - if a laminate counter top is
supplied, Apply silicone sealer to
the unde r-side of sink flange prior
to mounting.
- Step #6 Assemb ling the Steri lizer Tower -
1. Assemble t he tower
using the s ame p roce-
dure utilized in the
past st eps.
2.Attach th e Sterilizer
slide ou t shelves to
the side walls using
the su pplied e uro
screws located with
the slide out shleves.
3. Att ach the Sterilizer
tower to the othe r
assembled cabinet s
using 1 1/4" x 1/4" x
#20 flathead m achine
screws.
Note - Side walls ov er-
lap the back of t he
base cabinets by
approximately 3/4".
1 5/8“
wood screws
1 5/8“
wood screws
1 5/8“
wood screws
1“
wood screws
Sink Base
PAGE 9 OF 22
1. Lay the toe-board f ace down in front of attached levelers with
notch facing away from legs. Align plastic receivers with each
leg and tap into the continuous notch o n back side of
toe-board. Install metal leg c lips into receivers. Stand toe-
board up-right and tap lightly on face until clips snap against
legs.
Notch Facing
away from legs
Plastic Receivers
with Metal clip
All wires s hould termina te at the floor of the sink bas e and connections made by a licensed
electricia n in conjunction with local wiring codes.
ELECTRICAL
ULTRASONIC
LIGHT
CIRCUIT
TABLE TOP
OR OPTIONAL
REC ESSED
ULTRASONIC
STERILIZER
1
STERILIZER
2
120V
20A
STERILIZER
1
STERILIZER
2
LIGHT
CIRCUIT
ULTRASONIC
120V
20A
120V
20A
120V
20A
ELECTRICAL
Reinstall all drawers and d oors removed in the first step. Install s helf pegs and insert shelving
into appropriate compartm ents. Shelf pegs are located in each cabinet with adjust able
shelves. Make final hinge adjustments.
Note - Drawers are numbered starting at the top a nd run downward to insure they are returned
to the same position.
PAGE 10 OF 22
TABLE TOP
OR OPTIONAL
RECESSED
ULTRASONIC
AUTOCLAVE
STATIM
9.00
9.00
TIMER
11.00
21" RECESSED
TASK LIGHT
21" RECESSED
TASK LIGHT
WRAP DRAWER
WRAP DRAWER
5"
5"
5"
5"
5"
5"
OPTIONAL AIRGLIDE
KICK OPEN UPPER
CABINET DOORS AND
WASTE MODULE
OPTIONAL
TAPMASTER FAUCET
FOOT CONTROL
Note: See pages 19-22 for installation of optio na l Pneumatics
PAGE 11 OF 22
S olid Surface Care & Maintenance
CARE AND MAINTENANCE
Caring for your Wilsona rt Gibraltar Solid Surface countertop or surface is as simple as wiping th e surface
with a damp cloth. If a stain develops, wipe it away with so ap and water. Or if you prefer wipe it clean with
Windex.
If a stain doesn’t resp ond to soap and water, for a matte finish, apply an abrasive cleanser and buff with a
Scotch-Brite pad using a circular motion. The same technique can be used for cigarette b urns.
If you hav e a gloss finish, please contact your d ealer or fabrica tor before attempting repa irs.
For minor cuts and scratches, simply sand lightly with a medium (2 20 grit) sandpaper, then follo w with a
fine (320 grit) sandpaper. Finally, touch up the finish by buffin g with a Sc otch-Brite pad.
PRECAUTIONS
Do not expose the surface to harsh chemicals, such as pain t remover, turpe ntine, nail polish remover or
stove and drain cleaners. If the se chemicals come in cont act with the surface, immediately wash them off
with water, u sing appropriate safety measures to avoid injury.
Always use a cutting board instead of cutting directly on the surface. While mino r cuts and scratches can
be repaired, care should be take n to preven t them in order to keep th e surface looking as good as n ew.
PAGE 12 OF 22
Circuit Dia gra ms
PREFABRICAT ED DENTAL AS SEMBLY
FILE #E231530
Hospit al Grade / Redundant G rou nd
HOSPITAL GRADE
DUPLEX
RECEP TACLE
STERILIZER #1
+ BLACK
(HOT)
GREEN INSULATED
GROUNDING WIRE
DUAL STERILIZ ER RECEPTACLE
SEPARATE CIRCUITS (SAME BOX)
WIRING DIAGRAM ITEM #EL-280
Mark for sterilizers 1 & 2
STERILIZER #2
HOSPITAL GRADE
DUP LEX
RECEP TACLE
+ BLACK
(HOT)
ROUGH-IN BOX
RATED
120VOLT 20 AMP
CIRCUIT
ROUGH-IN BOX
RATED
120VOLT 20 AMP
CIRCUIT
PAGE 13 OF 22
SINGLE POLE
SWITCH
HOSPITAL GRADE
GFCI (GROUND FAULT)
RECEPTACLE
FLORESCENT LIGHT FIXTURE
GREEN INSULATED GROUNDING WIRE
FREE-S TANDING STERIL IZATION
WIRING DIAGRAM ITEM #EL-250
LIGHT CIRCUIT SINK AREA (STANDARD)
TASK LIGHT
MOUNTED UNDERNEATH
UPPER CABINET
DEDICATE D LIGHT CIRCUIT
120VOLT, 20 AMP
12-2 WIRE
LABEL
ROUGH-IN BOX
RATED 20 AMP
CIRCUIT
PAGE 14 OF 22
HOSPITAL GRADE
GFCI DUPLEX
RECEPTACLE
GFCI
RECEPTACLE
GREEN INSULATED GROUNDING WIRE
FREE-S TANDING STERIL ZATION
WIRING DIAGRAM ITEM #212
DUAL RECEPTACL E CIRCUIT SINK AREA (OPTIONAL)
ROUGH-IN BOX
RATED 20 AMP
CIRCUIT
REGULAR
RECEP TACLE
HOSPITAL GRADE
DUPLEX
RECEPTACLE
COMBINE WITH
LIGHT CIRCUIT ITEM #EL-240
120VOLT, 20 AMP
12-2 WIRE
LABEL
PAGE 15 OF 22
HOSPITAL GRADE
GFCI DUPLEX
RECEPTACLE
GREEN INSULATED GROUNDING WIRE
FREE-S TANDING STERIL ZATION
WIRING DIAGRAM ITEM #220
ULTRASONIC RECEPTACLE CIRC U IT (OPTIONAL)
ROUGH-IN BOX
RATED 20 AMP
CIRCUIT
REGULAR
REC EPTACLE
DEDICATE D ULTRASONIC
120VOLT, 20 AMP
12-2 WIRE
LABEL
PAGE 16 OF 22
Drawer Installation
A) Fully extend drawer glides from the cabinet. (Optional)
B) Place the drawer on the glides.
C) Push the drawer in completely.
D) Cycle drawer a couple times to ensure that the drawer is
securely attached to the glides.
Drawer Removal
A) Open drawer completely.
B) Lift up on the drawer front until the front of the box releases from the glide.
C) Pull out on the drawer slightly.
D) Lower the drawer back down while pulling out on the drawer.
Drawer Front Adjustment and Removal
1) Remove the cover caps on the drawer side by hand.
2) Height Adjustment: Rotate in either direction to adjust the drawer front vertically.
3) Tilt Adjustment: Adjust after the drawer front is installed to ensure the drawer sides meet
square with the drawer front. (Only available on large drawer boxes.)
4) Side Adjustment: Adjusts the drawer front horizontally. Turn in either direction.
5) Tension/Removal: For large drawers, turn the screw toward the front of the drawer until the
front detaches from the box. Repeat this procedure on both sides of the drawer. For small
and medium drawer boxes, turn the screw toward the back of the drawer to remove the
front.
Drawer Removal, Installation and Adjustment
Removal
A) Extend the glide to its outermost position.
Push the release levers in and remove the
drawer member of the sides.
Full Extension Glide Removal & Installation...
PUSH
PULL
Cabinet Member
Drawer Member
Installation
A) Line up the drawer member to the cabinet
member and push the drawer into its
compartment.
A
B
C
D
GA1106
GA1107
4
5
32
GA1105
A
B
C
Hinge 1 & 2 Adjustment
Direction Guide
Hinge 1 & 2 Adjustments
Use a phillips head screw driver for the following steps...
A) Screw A adjusts the door in direction A seen in the
Adjustment Direction Guide
B) Screw B adjusts the door in direction B. Equal
adjustment must be made to all hinges on the door for it
to move the desired distance.
C) Screw C adjusts the door in the C direction. Make
adjustments to top and bottom hinge as necessary.
Note: Use a level to ensure the door is level and plumb. Preferred gaps are
approximately 1/8” between doors and 1/16” between accents and doors.
180° Hinge Adjustments
D) Loosen screw D and adjust door gap
and angle using a level. Tighten screw D
when positioned correctly,
180° Hinge
D
Hinge 1 & 2 Removal
E) Press button at point E at the back of
the hinge and pull away from cabinet.
Door Removal, Installation, and Adjustment
B
C
A
Hinge 1
E
Hinge 1, 2, & 3 Installation
F) Hook the hinge to the mounting block at
point F
G) Latch at point G by pressing the hinge
against the hinge block.
F
G
Hinge 2
A
B
C
E
GA1044
BE
CA
Hinge 3
Soft Close
Switch
Door
Removal
PAGE 18 OF 22
Artizan
PAGE 19 OF 22
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Midmark Artizan® Sterilization Cabinetry - Streamline - SC120-200 Installation guide

Category
AV equipment stands
Type
Installation guide

Midmark Artizan® Sterilization Cabinetry - Streamline - SC120-200 offers a compact and efficient solution for dental practices seeking reliable sterilization and storage options. This free-standing unit combines advanced functionality with ergonomic design, providing ample space for essential equipment and supplies. The cabinetry is fully customizable, allowing you to tailor it to your specific workflow and space requirements.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI