WaterLogic WL200 Operating, Installation And Service Manual

Type
Operating, Installation And Service Manual

WaterLogic WL200 is a reliable and innovative water treatment system that provides exceptional quality and great tasting water with every use. It is equipped with BioCote® Anti-Microbial Protection, ensuring that the surfaces surrounding the dispensing areas and drip tray are protected from the growth of microorganisms. The large dispense area with recessed faucet further enhances hygiene by preventing cross-contamination. With its high volume storage and water capacity, the WL200 can meet the demands of various usage scenarios.

WaterLogic WL200 is a reliable and innovative water treatment system that provides exceptional quality and great tasting water with every use. It is equipped with BioCote® Anti-Microbial Protection, ensuring that the surfaces surrounding the dispensing areas and drip tray are protected from the growth of microorganisms. The large dispense area with recessed faucet further enhances hygiene by preventing cross-contamination. With its high volume storage and water capacity, the WL200 can meet the demands of various usage scenarios.

Waterlogic Commercial Products, LLC
11710 Stonegate Circle
Omaha, NE 68164
(800) 288-1891 www.waterlogic.us
Tech Portal Website: http://techportal.waterlogic.com
WL200
OPERATING, INSTALLATION, AND SERVICE MANUAL
WL200Operating,Installation,andServiceManual Page2‐Revision:4132016
WL200OPERATING,INSTALLATION,ANDSERVICEMANUAL
CongratulationsonyourchoiceoftheWaterlogicWL200watertreatmentsystem.TheWL200
modeldispensescoldwater.EveryWL200includes:
BioCoteAntiMicrobialProtection
Filterconfigurationcanbeoptimizedforallwaterconditions
TheWaterlogicWL200providesexceptionalqualityandgreattastingwaterwitheveryuse.
TABLEOFCONTENTS
FeaturesandBenefits.................................................................3
Certifications...............................................................................4
IntroductionandSafetyAlertSymbols.......................................5
SafetyPrecautions......................................................................6
ModelandPartDesignations......................................................7
Specifications..............................................................................7
OperatingInstructions................................................................8
FlowDiagrams.............................................................................9
AdjustingColdSetPoint............................................................11
PreInstallationProcedures......................................................12
DrainingProcedures..................................................................15
InstallationProcedures.............................................................18
ServiceRequirements...............................................................20
CounterTopDrawingsandPartsList……………………..................21
TowerDrawingsandPartsLists................................................26
ElectricalDiagrams....................................................................31
Troubleshooting........................................................................34
Warranty..................................................................................41
WL200Operating,Installation,andServiceManual Page3‐Revision:4132016
WL200FEATURESANDBENEFITS
ColdWater
WaterlogicWL200comesstandardwithColdWaterSelection.
HighVolumeStorageandWaterCapacity
TowerModelhas4litersofColdWaterCapacity.CounterTophas2litersofColdWaterCapacity.
BioCote®AntiMicrobialProtection
Plasticsurfacessurroundingdispensingareasanddriptrayareinfusedwithan
exclusivesilveradditivecalledBioCote®.Silverisanaturalantimicrobialthat
inhibitsthegrowthofmicroorganismsprovidingadditionalsurfaceprotection.
LargeDispenseAreawithRecessedFaucet
8.5inchdispenseheightwithBioCote®recessedfaucettoprotectfromcrosscontamination.

WL200Operating,Installation,andServiceManual Page4‐Revision:4132016
WL200CERTIFICATIONS
Waterlogicwatertreatmentsystemshavebeentested,andcertifiedtorigorousNSFandUL
Standards.WebelievethatperformancetestingandcertificationsvalidateWaterlogicasaworld
leaderinwatertreatmentsystems.
WL200CertificationsInclude
UL399CertifiedDrinkingWaterCooler
IntertekLabs(ETL)CertifiedtheWL200toANSI/UL399StandardforDrinkingWater
Coolers.
BPAFree‐WaterlogictestsforBPAanddeclaresthatallofitsproductsareBisphenolA
FREEandcontainnoharmfulBPAplastics.
WaterlogicmanufacturingiscertifiedtoISO9001QualityManagement
Systems(certifiedbyMoodyInternational).ISO9001isthe
internationallyacceptedstandardforwellmanagedorganizationsthat
haveadoptedthekeyqualitymanagementprinciplestoitsoperationsto
bringconsistentqualityproductsandacultureofcontinuous
improvement.
SafeDrinkingWaterAct
WaterlogicwatertreatmentsystemsconformtotheSafeDrinkingWaterAct(SWDA)“leadfree”
amendmenteffectiveJanuary4,2014.

WL200Operating,Installation,andServiceManual Page5‐Revision:4132016
INTRODUCTION
CarefullyreadandfollowallinstructionstoensureproperandefficientoperationofyourWL200.
ContactWaterlogicoranAuthorizedWaterlogicDealerifyouhaveanyquestions.
WaterlogicandAuthorizedWaterlogicDealersemploytrainedservicepersonnelwhoare
experiencedintheinstallation,functionandrepairofWaterlogicequipment.Thispublicationis
writtenforusebythesequalifiedindividuals.Waterlogicencouragesuserstolearnaboutproducts,
however,webelievethatproductknowledgeandserviceisbestobtainedbyconsultingWaterlogic
oranAuthorizedWaterlogicDealer.
Waterlogicwatertreatmentsystemsshouldbecombinedwithselectedwatertreatment
componentstocreateasystemspecificallytailoredforeachapplicationbytrainedandqualified
personnel.
ProductsmanufacturedandmarketedbyWaterlogicanditsaffiliatesareprotectedbypatents
issuedorpendingintheUnitedStatesandothercountries.
Waterlogicreservestherighttochangethespecificationsreferredtointhisliteratureatanytime,
withoutpriornotice.ChangesormodificationsnotexpresslyapprovedbyWaterlogiccouldvoidthe
warrantyanduser’sauthoritytooperatetheequipment.
SAFETYALERTSYMBOLS
Readandfollowallsafetyinformationcarefully.Thesignalwordsusedinthismanualareselectedas
shownbelowandbasedonanassessmentofthedegreeofpotentialinjuryordamage(severeor
minor)andtheoccurrenceofinjury(definitelyoccursorhasthepotentialtooccur)whenthe
warningisignored:
DANGER!
Indicatesasituationwhich,whennotavoided,resultsindeathorsevereinjury.
WARNING!
Indicatesasituationwhich,whennotavoided,hasthepotentialtoresultindeathorsevere
injury;and/orseverepropertydamage.

CAUTION!
Indicatesasituationwhich,whennotavoided,resultsorhasthepotentialtoresultinminor
injury;and/orminorpropertydamage.

WL200Operating,Installation,andServiceManual Page6‐Revision:4132016
SAFETYPRECAUTIONS
Basicsafetyprecautionsshouldbefollowed,includingthefollowing:
DANGER!Ifincorrectlyinstalled,operatedormaintained,thisproductcancausedeathor
severeinjury.Thosewhoinstall,operate,ormaintainthisproductshouldbetrainedinitsproperuse,
warnedofitsdangers,andshouldreadtheentiremanualbeforeattemptingtoinstall,operate,or
maintainthisproduct.
WARNING!Unitistobeusedforitsintendedpurposeasdescribedinthismanual,and
untrainedindividualswhousethismanualassumetheriskofanyresultingpropertydamageor
personalinjury.
DANGER!ELECTRICALSHOCKHAZARD.Alwaysunplugfrompowersupplypriortoservicing
equipmenttopreventelectricalshock.
WARNING!Thissystemtobeusedforwateronlyandisnotintendedforusewherewateris
microbiologicallyunsafeorwithwaterofunknownqualitywithoutadequatedisinfectionbeforeor
afterthesystem.Thesystemisdesignedforthesupplementalbactericidaltreatmentofeither
treatedanddisinfectedpublicdrinkingwater,orotherdrinkingwater,whichhasbeentestedand
deemedacceptableforhumanconsumptionbythestateorlocalhealthagencyhavingjurisdiction.
Thesystemisdesignedtoreducenormallyoccurringnonpathogenicornuisancemicroorganisms
only.Systemisnotintendedfortreatmentofcontaminatedwater.
WARNING!DispenserCouldTiporFallcausingseriousinjury.Alwaysinstallunitonafirm,flat,
andlevelsurfaceandsecuretheWL200tothebasecabinetwiththescrewprovidedtolockthe
componentstogether.Neverplaceheavyitemsontopofunitandneverclimb,stand,orhangonunit
orstoragecabinettopreventinjuryanddamage.

CAUTION!INDOORUSEONLY.Donotinstalloutdoorsorwhereunitisindirectsunlight.Donot
installwhereambienttemperaturegoesbelow50Forabove97F.Avoidhighhumidityandmoisture.
Productlifeandperformancewillbeimpactedandwarrantycouldbevoided.
WL200Operating,Installation,andServiceManual Page7‐Revision:4132016
MODEL/PARTDESIGNATIONS
BRANDNAME DESCRIPTION
MODEL‐
PARTNUMBER
WL200CounterTop
WaterlogicWL200CounterTop‐ColdWater
F6002MCTTCSWLU
12WL200CT
WL200Tower
WaterlogicWL200Tower‐ColdWater
F6002FSCTTCSWLU
12WL200FS
SPECIFICATIONS
ITEM WL200CounterTop WL200Tower
WaterConnection ¼”QuickConnect
ColdWaterTemperature
ColdWaterTemperature
FactorySetPoint41°‐ 5°C
(Adjustable)34° - 54° F.(1.1°‐12.2°C)
RecommendedService
Pressure
4060psi(275414kPa)UsePressureRegulator
MaximumServicePressure 100psi(689kPa)UsePressureRegulator
RatedServiceFlow 0.5gallonsperminute(1.89Lpm)
EnvironmentalTemperature35°‐100°F(2°‐37°C)
RefrigerantGas R134a,40g,1.41ounces R134a,65g,2.29ounces
R134aPressures High(230psi),Low(90psi)
SHIPPINGSPECIFICATIONS
ITEM WL200CounterTop WL200Tower
Width/Depth/Height
13.5”x14.5”x17.75”
#
(34cmx37cmx
45cm)
13.5”x14.5 x40.5”(34cmx41cmx
103cm)
Weight(dry) 42pounds(19.5kg) 58pounds(26.5kg)
ELECTRICALSPECIFICATIONS
ELECTRICALSUPPLY 120V/60Hz,1PH 15AmpService
COMPONENT POWER(approximate) AMPDRAW(approximate)
Compressor 216 1.8Amps
WL200TOTAL 216 1.8Amps
#WL200CounterTopis17.75in.tallandmaynotfitbetweenCounterTopsandcabinets‐Checkinstallationtoensureadequateclearance.
WL200Operating,Installation,andServiceManual Page8‐Revision:4132016
OPERATINGINSTRUCTIONS
TheabovepictureshowsfrontLCDdisplayandcontrolpanelfortheWaterlogicWL200.
ForColdWater: PresstheDispensingButton.

DispensingButton
WL200Operating,Installation,andServiceManual Page9‐Revision:4132016
WL200COUNTERTO PWATERFLOWDIAGRAM
WL200Operating,Installation,andServiceManual Page10‐Revision:4132016
WaterIn
FilterDryer
SolenoidValve
Compressor
Condenser
WaterOut
Faucet
WL200TOWERWATERFLOWDIAGRAM

WL200Operating,Installation,andServiceManual Page11‐Revision:4132016
ADJUSTINGCOLDSETPOINT
Thecoldsetpointcanbeadjustedbyaccessingthecoldthermostat
adjustmentscrewUndertheDecalattherearoftheunit.
ThiswillNOTVoidtheWarrantyasthecurrentDecalstatesonthebackof
theunit.Thefactorysetpointis~41°Fandisindicatedbythedotonsheet
metalaroun
dtheadjustmentscrewandbehindthedecal.
Turningtheadjustmentscrewclockwiselowersthesetpointtemperature
andtherangeisapproximately20°Fthruthefullrangeofadjustment
(~7:00tothe~5:00positions).
Youshouldbeabletoturnthescrewfromthefactorysetpointof41°F
(~12:00position)about45degreesclockwise(2:30onaclock) toreduce
thesetpointtemperatureby6°Fandachievethe3536°Fsettingyouare
lookingfor.

Trialthisbyadjustingandthenmeasurethewatertemperature1015
minutesafterthecompressorshutsoff(coldestpoint)toverifytheset
pointtemperature.

Eachunitwillvaryslightly.Trynottogomuchpastthe“3:00position”to
avoidfreezingthecoldtankasshownabove.
FutureProductionchangesColdThermostatCoverLabeltoLP0326L00
00/WLUSAPNLP0326.
WL200Operating,Installation,andServiceManual Page12‐Revision:4132016
PREINSTALLATIONPROCEDURES
DANGER!ELECTRICALSHOCKHAZARD.
Onlyqualifiedpersonnelwhohavereadandunderstandthisentiremanualshouldattemptto
install,orservicethisunit,failuretodosocouldresultindeathorseriousinjury.DONOTplug
intoanelectricalsupplyuntilspecificallyinstructed.
WARNING!ALWAYSSANITIZEBEFOREUSE.
Sanitizebeforeusetoeliminateanypotentialmicrobiologicalcontaminates.
MaterialsNeeded:
PersonalProtectiveEquipment.RubberorNitrileSafetyGlovesandProtectiveEyewear
PhillipsScrewdriver
TemperatureGage
WaterPitcherorContainertocollectwaterfromthefaucet
5galloncontainerordrainbasin
Sanitizer‐HouseholdBleach(5.25%SodiumHypochlorite)orCitricAcidBasedCleaner
¼”PlasticTubing,atleast4feetinlength,andassorted¼”quickconnectfittings
TDSMeterandTestStripsformeasuringchlorine‐Optional
1. UnpacktheWaterlogicWL200andcheckexteriorfordamage.

Sanitizing
SanitizeusingaHouseholdBleach(5.25%SodiumHypochloritesolution)orotherapproved
cleanerthroughoutthecoldandsparklingwatercircuits.Followallinstructionsonthesanitizer
andflushwithfreshwaterthroughthefaucetuntilodorandtasteisacceptable.
WARNING!USEPROPERPERSONALPROTECTIVEEQUIPMENT
Alwaysensureproperventilationanduseproperpersonalprotectiveequipmentsuchasgloves
andeyeprotectionwhenusingchemicals.RefertoMaterialSafetyDataSheetforspecific
requirementsofeachchemicalproduct.Takeallnecessaryprecautionstopreventsanitizerfrom
contactingeyes,clothing,andanyothersurfacesincoulddamage(carpets).
2. Put1teaspoonofsanitizerperdirectionsoruseBleachSolution(1teaspoon=1/6oz.=5ml=½
capfull)ofhouseholdbleach(SodiumHypochlorite5‐10%Concentration)intheSanitizing
Cartridge.Alwaysensuresanitizeriscompatiblewithstainlesssteelandacetylplastic.
3. Connectsanitizingcartridgetoinletwatersupplyandconnecttoinletbulkheadfittingonbackof
unit.Turnonwatersupply.
4. ConnectpowertoWL200.DONOTTURNONREDPOWERSWITCHATTHISTIME
O=OFF.
WL200Operating,Installation,andServiceManual Page13‐Revision:4132016
FilltheColdCircuitwithSanitizer
5. Depressthemaindispensingbuttononthefrontcontrolpaneluntilcoldwater/sanitizingsolution
comesoutthefaucet.NOTE:Containeranddrainbasinwillberequiredtocatchthewaterfrom
thefaucet.
WARNING!UsePersonalProtectiveEquipment.GlovesandEyeProtectionRequired.Thefirst
2or3gallonsofwaterwillcontainconcentratedsanitizer.Useextremecare!
6. TurnoffwatersupplyandremoveSanitizingCartridgefrominletwatersupply.Reconnectwater
supplytoinletbulkheadfitting.
FlushFilters
CAUTION!FILTERFLUSHREQUIRED.
WL200’sarenotsuppliedwithfilters.Filtersshouldbeconfiguredtooptimizeyoursystem.Filters
needtobeconfiguredandspecifiedtodothejobgiventhelocalwaterconditions,usage,
maintenanceschedule,andplacementrestrictions.

Inorderforthefilterstoperformasrepresentedandtoprovidethebestqualitywaterpossible,it
isessentialthatfiltersbereplacedperiodically.Thefrequencyoffilterchangesdependsuponyour
waterqualityandyourwaterusage.Forexample,ifthereisalotofsedimentand/orparticlesin
yourwater,thenyouwillhavetochangeyourfiltersmorefrequentlythanalocationwithlittleto
nosediment.Besuretoreplaceyourfilterswheneveryounoticeadeclineintheperformance,
whetheritisadropinflowrateand/orpressureoranunusualtasteinthewater.
7. Flushthoroughlyperfiltermanufacturers’recommendationwithfreshwatertodrain.
8. Onceflushed,installthefilters.Followingtheflowdirectiononthefilter.
NOTE:

Filtersshouldnotbeflushedpriorto24hoursbeforeinstallationtolimitMicrobial
Growth.
9. ConnectWL200topower.

WL200Operating,Installation,andServiceManual Page14‐Revision:4132016
FlushingtheSanitizerfromtheMachine
10. Placeapitcher,catchbasin,orothercontainerunderthefaucetoftheWL200.
11. FlushtheColdTank.Runseveralgallonsofwaterthroughthefaucetbydispensingcoldwaterto
diluteandremovethesanitizerfromthecoldcircuit.Youcanusechlorineteststripstoevaluate
thewater.
12. Oncethesanitizerodor/tastehasbeenflushedoutofthecoldsideofthemachineth
e
sanitizationprocessfortheColdCircuitisnowcomplete.

WL200Operating,Installation,andServiceManual Page15‐Revision:4132016
WL200COUNTERTOPDRAININGINSTRUCTIONS
DrainingNotes
DraintheWL200fortransportation.
WARNING!STOREUNITEMPTY.ALWAYSSANITIZEBEFOREREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbialgrowth).
DisableColdTank
1. TurnofftheRedPowerSwitchtodisablecompressor.O=OFF
TurnoffWaterSupplyandBleedWaterPressure
2. Isolatetheunitfromfeedwaterbyturningoffthesupply.
3. Dispensecoldstillwatertorelieveanypressurebuiltupinthesystem.
4. Removethewatersupplylinefromtheinletlinebulkheadfittingatbackofmachine.
5. Installdustcaporplugintowatersupplylinebulkheadfitting.
DraintheColdWaterTankandCircuit
6. Removetopcover.
7. Removefrontpanel.Remove2Phillipscrews
securingfrontpanel.Unseatfaucetassembly
frompanel.UnclipwiresfromPCB.
WL200Operating,Installation,andServiceManual Page16‐Revision:4132016
8. Disconnecttubingfrominletelbowfrom
solenoidandallowwatertodrain.
9. Reconnecttubingintoinletelbow,
10. Dryinsideofunit.
11. Replacefrontpanel.

WL200Operating,Installation,andServiceManual Page17‐Revision:4132016
WL200TOWERDRAININGINSTRUCTIONS
DrainingNotes
DraintheWL200fortransportation.
WARNING!STOREUNITEMPTY.ALWAYSSANITIZEBEFOREREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbialgrowth).
DisableColdTanks
1. TurnofftheRedPowerSwitchtodisablethecompressor.O=OFF
TurnoffWaterSupplyandBleedWaterPressure
2. Isolatetheunitfromfeedwaterbyturningoffthesupply.
3. Dispensecoldstillwatertorelieveanypressurebuiltupinthesystem.
4. Removethewatersupplylinefromtheinletlinebulkheadfittingatbackofmachine.
5. Installdustcaporplugintowatersupplylinebulkheadfitting.
DraintheColdWaterTankandCircuit
6. Removelowerfrontpaneltoaccesstankfeedlines.

7. Disconnecttanklinefeedlinefromcoldinletsolenoidto
drainintobasinorcatch.
8. Reconnecttubingintoinletelbowoncedrained.
9. Dryinsideofunitifnecessary.
10. Replacelowerfrontpanel.
WL200Operating,Installation,andServiceManual Page18‐Revision:4132016
INSTALLATIONPROCEDURES
SafetyandInstallationGuidelines
EnsureallLocal,State,andFederalLawsandCodesincludinghealthandsafetyguidelinesaremet
wheninstallingWaterlogicEquipment.Onlyqualifiedservicetechniciansshouldattempt
installationandserviceofWaterlogicEquipment.
WARNING!ELECTRICALSHOCKHAZARD.Alwaysunplug(isolatefrompowersupply)toprevent
electricalshockexceptwhereelectricaltestsarespecified.
WARNING!IMPROPERSUPPLYORCONNECTIONCANRESULTISRISKOFSHOCK.
Connecttoa15amp120V60Hzproperlygroundedoutlet(GFIisrecommended).Ensurepolarityis
correctandalwaysusea3prongoutlet.Consultaqualifiedelectricianifyouhaveanyquestions.
WARNING!USEONLYWaterlogicSUPPLIEDPOWERCORD.Locatesystemwithin5feetof
powersupply.Neveruseanextensioncordoradapter.Donotuseadamagedpowercordorplug.
Keeppowercordoutofheavytrafficareasandawayfromheatsources.Donot,underany
circumstances,removegroundprongoralterthepowercord.Neverpullthepowerplugfromthe
outletwithawethandorallowtheplugtogetwet.Failuretousethesuppliedpowercordwillvoid
ULCertificationandWarranty.
CAUTION!INDOORUSEONLY.Neverexposetodirectsunlight,heatsources,orambientair
temperatureabove100°F(37°C)orbelow35°F(2°C).Installindoorsandkeepunitawayfrom
excessivehumidity.Neverexposetofreezingtemperatures.Ensurethereisadequateclearance
aroundtheunittoallowrefrigerationsystemcondensertodissipateheat.Warmerenvironments
requiremoreclearancearoundtheunit.Minimumclearancearoundallsurfacesofthemachineis2
inches.Installswheretheambienttemperatureexceed80F,requireaminimumof4inchesclearance
forproperheatdissipationandefficientoperation.
CAUTION!USEAWATERPRESSUREREGULATOR.Waterlogicwillnotberesponsibleforinjuryor
damagecausedbyexcessivewaterpressure.Operatingpressuremustbe40psito60psi.Beaware
anyofpotentialpressuresurgescausedbybuilding/municipalpumpingstations.
CAUTION!USEUVSTABILIZEDSUPPLYLINES.Feedtheunitwithapotableambientorcold
watersupplyonly.Feedwaterover100°F(37°C)candamagethetreatmentcomponents.Water
blockdevicesandexternalleakdetectorsarestronglyrecommended.Locatetheunitasclosetothe
watersupplyandtheelectricalconnectionsaspossible.
WARNING!STOREANDTRANSPORTUNITEMPTY.ALWAYSSANITIZEBEFOREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbiologicalcontamination(potentialbacterialgrowth).Sanitizebeforeusetoeliminateany
potentialmicrobiologicalcontaminates
Preinstallationandsanitizationproceduresasprescribedinthismanualmustbeperformedbefore
installingtheWL200.
AlwaysinstallindoorsandplacetheWaterlogicWL200onafirm,flatandstablesurface.
WL200Operating,Installation,andServiceManual Page19‐Revision:4132016
1. Attachthewatersupplylinetothe1/4”feedwaterinletbulkheadfittingonthebackoftheunit.
Waterlogicrequirestheuseofawaterpressureregulator.Waterfeedpressuremustbe
between4060psi.Turnonthewa tersupplyandcheckforleaks.

2. ChecktoensurethattheRedPowerSwitchisoff.O=OFF
3. ConnectthepowercordtothebackoftheWaterlogicWL200andtoa120Voltsupply.
4. FilltheColdTank.Holdacontainerunderthedispensingfaucet,pressandholdthemain
dispensingbuttonuntilacontinuousflowofwaterisobtained.Onceacontinuousflowis
obtained,releasethedispensingbutton.Coldtankisnowfull.
5. MovetheWaterlogicWL200intoitsfinaloperatingposition.Be surethataminimumof2”
clearanceismaintainedaroundboththesidesandthebackoftheunit.Thisisimportanttoallow
properairflowandheatexchangeofrefrigerationsystem.
6. Levelunitusingtheadjustablefeettolevelifnecessary.Neverinstallonincline.
7. TurntheRedPowerSwitchon.I=ON.
8. WhentheunithasreacheditsColdTempSetPointTemperature,thecompressorwillcycleoff.
9. Oncetheunitisatthetargettemperature(s),samplethewatertoensurewatermeets
expectationsandadditionalrinsingoradjustmentisnotrequired.
10. Checktheunitforanyleaks.ExternalLeakProtectionisalwaysrecommended.

WL200Operating,Installation,andServiceManual Page20‐Revision:4132016
SERVICEREQUIREMENTS
WARNING!Readandunderstandthecontentsofthismanualbeforeattemptingtoservice
WL200.Failuretofollowtheinstructionsinthismanualcouldresultindeath,seriouspersonal
injury,orseverepropertydamage.Onlytrainedandqualifiedtechniciansshouldattemptto
install,maintain,orserviceWaterlogicEquipment.
1. Visuallyinspectallelectricalandwaterconnectionsforsignsofwearordamage.
DANGER!HIGHVOLTAGEELECTRICALHAZARD.Unplugbeforeinspectionandservice.
2. Ensurethereisadequate(minimumof2”)clearancearoundtheunitandcleanthecondensergrill
andcompressorfantoprovideefficientcoolingsystemoperation.
3. Sanitizethecoldtankperinstructionsinthepreinstallationprocedures.
4. Cleanandsanitizeexternalsurfacesoftheunit.Usesoapandwaterorchemicalsthatare
compatiblewithABSplasticandwillnotdamageordegradetheproductsurfaces.
5. RemoveandcleantheFaucet.Replaceasneeded.
WARNING!SANITIZERMAYCONTAINHAZARDOUSCHEMICALS.Useofproperpersonal
protectiveequipmentsuchasrubberglovesandeyeprotectionisrequired.

  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41

WaterLogic WL200 Operating, Installation And Service Manual

Type
Operating, Installation And Service Manual

WaterLogic WL200 is a reliable and innovative water treatment system that provides exceptional quality and great tasting water with every use. It is equipped with BioCote® Anti-Microbial Protection, ensuring that the surfaces surrounding the dispensing areas and drip tray are protected from the growth of microorganisms. The large dispense area with recessed faucet further enhances hygiene by preventing cross-contamination. With its high volume storage and water capacity, the WL200 can meet the demands of various usage scenarios.