©2017 SwellPro All Rights Reserved 17
3. Indication lights: One LED on indicates a charge level of 25% , two LEDs on indicate a
charge level of 50%, three LEDs on indicate a charge level of 75%, four LEDs indicate that the
battery is fully charged.
1. In low temperature environments (-10C degrees to 5C degrees) , the flight time will be
reduced. Before use, please fully charge the battery, and keep it warm.
2. In low temperature environments, it is recommended to stop flying if and when the low
battery alarm is on.
3. In low temperature environments, it is recommended to preheat the battery before flying.
Low temperature precautions
When inserting the battery, please take note
and observe the following precautions:
Please ensure the battery is “lying on it’s side”
with the cables exiting the battery towards the
rear of the drone,
Please observe the label on the battery.
Please observe the instructions and the arrow
on the label.
Battery Installation
Before charging, please ensure that you are using the correct battery type.
If, during the charging process, the 4 indicator lights flash at the same time, this
indicates a charger or battery failure, please stop charging.
There are two low battery alarms, which can be set by adjusting the parameters in the
setup. The first level is at 14.8V, the red LED on the drone will flash three times, the
second level is at 14.4V, at this level, the red LED will flash continuously, while the drone
will commence its auto landing sequence.
Please Note: There are no low battery alarms on the controller.
While operating the drone, please monitor the battery voltage level, and keep the
voltage level in mind, when the level has dropped to 14.8V, please prepare to return the
drone to a safe landing place.
It is dangerous to continue flying the drone once with insufficient battery power. This
could result in damage to the battery.