Midmark Integra™ Operatory Cabinetry - Side Cabinetry Installation guide

Category
Sanitary ware
Type
Installation guide

Midmark Integra™ Operatory Cabinetry - Side Cabinetry offers versatile storage solutions for your dental operatory. With adjustable shelves, pull-out trays, and swing-out tubs, you can customize the cabinet to meet your specific needs. The durable laminate construction ensures long-lasting use, while the easy-to-clean surfaces help maintain a hygienic environment.

Midmark Integra™ Operatory Cabinetry - Side Cabinetry offers versatile storage solutions for your dental operatory. With adjustable shelves, pull-out trays, and swing-out tubs, you can customize the cabinet to meet your specific needs. The durable laminate construction ensures long-lasting use, while the easy-to-clean surfaces help maintain a hygienic environment.

1
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
003-1930-00 Rev. B (1/12)
OSC055S-L (55” LH Sink / Storage Unit
OSC055S-R (55” RH Sink / Storage Unit
OSC064S-L (64” LH Sink / Storage Unit
OSC064S R (64” RH Sink / Storage Unit
55”, 64” Square Sink / Storage Unit Installation
Applies to Models:
OSC055S, OSC064S
Special Tools:
Level
1/4” deep well socket
Caulking Gun
Belt Sander
OSC064S-L (Shown)
DA2186i
NextNext
BackBack
midmark.com
Style A
2
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
Note
All plumbing must be made by a licensed plumbing contractor and
conform to local, city, and national codes pertaining to the installation.
LEFT CABINET DIMENSIONS
DA2225i
WALL
FLOOR MOUNT SERVICE
HOT
COLD
3/4 in (1.9 cm) Hole
1/2 in NPT Water Pipe
Stub out 1 in (2.5 cm) Min.
2-1/2 in (6.4 cm) Max from
finished floor surface.
Use 1/2 in male NPT fitting
on end of stubs for connections
to shut-off valves. Install 1/2 in
inlet x 3/8 in O.D. outlet angle
shut-off valves.
Waste drain 2 in (5.1 cm) hole
1.5 in (3.8 cm) drain pipe
3 in
7.6 cm
4 in
10.2 cm
Waste drain
2 in (5.1 cm)
hole
1-1/2 in drain
pipe
HOT
COLD
FLOOR
3/4 in (1.9 cm) Hole
1/2 in NPT Water Pipe
Stub out 1-3/4 in (4.5 cm) Min.
3-3/4 in. (9.5 cm) Max from
finished wall surface .
Use 1/2 in male NPT fittings on end of
stubs for connections to shut-off valves.
Install 1/2 in inlet x 3/8 in O.D. outlet
angle shut-off valves.
WALL MOUNT SERVICE
16-1/4 in (41.3 cm)
3 in
7.6 cm
13-1/4 in (33.7 cm)
NextNext
BackBack
midmark.com
Style A
3
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
RIGHT CABINET DIMENSIONS
Note
All plumbing must be made by a licensed plumbing contractor and
conform to local, city, and national codes pertaining to the installation.
DA2226i
WALL
FLOOR MOUNT SERVICE
HOT
COLD
3/4 in (1.9 cm) Hole
1/2 in NPT Water Pipe
Stub out 1 in (2.5 cm) Min.
2-1/2 in (6.4 cm) Max from
finished floor surface.
Use 1/2 in male NPT fitting
on end of stubs for connections
to shut-off valves. Install 1/2 in
inlet x 3/8 in O.D. outlet angle
shut-off valves.
Waste drain 2 in (5.1 cm) hole
1.5 in (3.8 cm) drain pipe
3 in
7.6 cm
4 in
10.2 cm
Waste drain
2 in (5.1 cm)
hole
1-1/2 in drain
pipe
HOT
COLD
FLOOR
3/4 in (1.9 cm) Hole
1/2 in NPT Water Pipe
Stub out 1-3/4 in (4.5 cm) Min.
3-3/4 in. (9.5 cm) Max from
finished wall surface .
Use 1/2 in male NPT fittings on end of
stubs for connections to shut-off valves.
Install 1/2 in inlet x 3/8 in O.D. outlet
angle shut-off valves.
WALL MOUNT SERVICE
16-1/4 in (41.3 cm)
3 in
7.6 cm
13-1/4 in (33.7 cm)
NextNext
BackBack
midmark.com
Style A
4
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2174i
Step 1: Lift or push down release
levers (one per side) and
slide out drawer assembly.
Step 1: Pull drawer outward
until it hits stop.
Step 2: Pull sides of drawer outward
while lifting to free back of
drawer from hooks and remove.
2” Metal Frame Drawers
or
Writing Surface Assembly
All Molded Drawers
DRAWER REMOVAL
(If Required for Access)
NextNext
BackBack
midmark.com
Style A
5
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2188i
DESIRED POSITION OF EDGE OF UNIT
LOWER
CABINET
1 1/2" (max.)
(3.8 cm)
RAISE
CABINET
SINK / STORAGE UNIT INSTALLATION
Equipment Alert
Do not adjust leveling screws more then
1 1/2” (3.8 cm) to prevent lose of stability.
Step 1: Remove bottom
panels from cabinet.
Step 2: Adjust leveling screws
to fully lowered position
and move cabinet to
desired position.
Step 3: Level cabinet with
leveling screws.
NextNext
BackBack
midmark.com
Style A
6
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2189i
SINK INSTALLATION &
PLUMBING CONNECTIONS
LAMINATE TOP SHOWN
Step 1: Caulk around perimeter of
hole, then position sink.
Step 5: Refer to the instructions with
Tapmaster™ faucet controller
for installation procedure.
Step 4: Install faucet and soap
dispenser using instructions
included with those items.
Note
All plumbing must be made by a licensed
plumbing contractor and conform to local,
city, and national codes pertaining to the
installation.
Equipment Alert
When installing a sink, Midmark
recommends securing cabinet to wall.
Failure to comply may result in damage
to plumbing connections.
Step 3: If required, caulk around
perimeter of hole and
install waste ring.
Step 2: Secure sink with bracket kits
included with sink.
NextNext
BackBack
midmark.com
Style A
7
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2190i
DOOR HINGE ADJUSTMENT
Vertical Adjustment
A) Loosen both screws.
B) Move up or down.
C) Retighten screws.
Horizontal Adjustment
A) Turn cam screw to move
panel side to side.
Depth Adjustment
A) Turn cam screw to move
panel front to back.
Note
Doors should be adjusted for the
gap specified on the illustration.
NextNext
BackBack
midmark.com
Style A
8
© 2008 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2229i
Adjusting Shelf
Remove shelf (not shown) and relocate
shelf brackets at desired position.
Relocating Pull-Out Shelf
Remove six screws from shelf slides and
relocate pull-out shelf in desired position.
Relocating Swing-Out
Tub and/or Shelf
A) Loosen screw so the shelf or tub is loose.
B) Move shelf forward and out to remove. Remove
screw, then re-install at desired location (do not
tighten). Position shelf, then tighten screw.
NextNext
BackBack
midmark.com
Style A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Midmark Integra™ Operatory Cabinetry - Side Cabinetry Installation guide

Category
Sanitary ware
Type
Installation guide

Midmark Integra™ Operatory Cabinetry - Side Cabinetry offers versatile storage solutions for your dental operatory. With adjustable shelves, pull-out trays, and swing-out tubs, you can customize the cabinet to meet your specific needs. The durable laminate construction ensures long-lasting use, while the easy-to-clean surfaces help maintain a hygienic environment.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI