Hardware Setup, Settings, Pinout, SL-R3 Firmware
Upgrade, GNSS Firmware Upgrade
MC-i3 and SL-100
MC-I3 and SL-100
Topcon Europe Positioning
Rugged Housing for
Construction Environment
Ingress Protection:IP-67
Network RTK Connectivity
Input Voltage: 9 32 V DC
Operating Temp:-30
o
C to+70
o
C
Features: SL-100/MC-i3
New Indicate MC receiver
Vanguard™ Technology
Internal SL-R3, Dig UHFII
Single or Dual GPS configurations
2 Deutsch connectors serial and
Ethernet to
GX-60 or GX-30
TNC connectors for radio and GPS
antenna
Dip Switch Settings
Install SIM Card
SL-R3 Antenna
Hardware setup
Hardware
MC-i3 / SL-100 Main B
PC ethernet
connection
Contains:
1001270-01 Ethernet Cable to configure SL-R3
MC-i3 / SL-100 Data cable kit 1001271-01
MC-i3 / SL-100 Data cable kit 1001271-01
Power
Serial 1 (Main board)
Serial 2 (Aux board)
Contains:
1001269-01 Serial Cable to configure GPS boards
MC-i3 / SL-100 Main A
Connectors pin outs
How to enter the SL-R3 to change settings.
GX-60 or Computer
Take 1001269-01 cable to power up the box
only.
Use 1001270-01 cable for tcp/ip connection to
slr-3
Connect ethernet and powerup the mci3 and follow the steps below.
In “control panel” network and sharing center” use the local area connection
Set Computer Ethernet Port to match with right picture.
Type 192.168.0.1 in your browser( chrome or QT web browser will do)
When prompted for the user name and password,
enter admin” for both and click “ok”
Check SL-R3 Firmware
SLR-3 Firmware update:
Select the download of latest firmware release and reboot after loading.
2
3
1
4
Configure SIM Card
Go to settings/ports/gprs
ATD*99***1#
After save all settings Reboot
Check connections and GSM status.
GNNS Firmware update MC-i3 via SLR-3
- Use GX-60 or PC
- Use cable 1001269-01 Power & Serial Cable’s
- Use 1001270-01 cable for tcp/ip connection to slr-3
- Follow procedure described in next slides.
MC-i3 GNNS FW update via GX-60 or PC
Please select serial port 1 and 2 to function with GPS and save
MC-i3 GNNS FW update via GX-60 or PC
Primary GPS
uncheck “Enabled” to disable
gps communication to SLR3.
In case of dual GPS:
Secondary GPS
uncheck “Enabled” to disable
when you update the firmware
for this card too.
Save this and go to
Firmware Upgrade tab.(next slide)
After update and reboot tick “Enabled” in the configuration tab again to
restart using the gps communication to the SLR-3 .(do not forget!)
/