ADTRAN MX3 4-PORT 10 Job Aid

Type
Job Aid
MX3ETH4
Module
P/N: 1189902L1
CLEI: M3LIPC0A_ _
MX3 4-PORT 10/100BASE-T ETHERNET MODULE
ETHERNET PIN ASSIGNMENTS FOR PORTS 1-4
COMPLIANCE
The MX3ETH4 Module complies with NEBS Level 3 and is NRTL listed to UL60950. It is
intended to be installed in Restricted Access Locations only.
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the users
authority to operate this equipment.
ETHERNET Pin List
Pin Function
1 TX+
2 TX–
3 RX+
4 NC
5 NC
6 RX–
7 NC
8 NC
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC)
Installation Code (IC) A
DESCRIPTION
The ADTRAN
®
MX3 4-Port 10/100Base-T Ethernet Module (MX3ETH4) is a plug-in
module for the MX3 Chassis (P/N 1189001L1). The MX3ETH4 Module is deployed with
redundant or non-redundant MX3112 Controller Cards (P/N 1189901L1); however,
redundant MX3ETH4 Modules are not used with the MX3 Chassis. The MX3ETH4 Module
interfaces the MX3112 Controller Card with the four client 10/100Base-T signals.
The MX3ETH4 Module is always installed in module slot
A of the MX3 Chassis.
ETHERNET PORTS
The four Ethernet ports located on the MX3ETH4 Module provide the protection and
physical interface for the MX3112 Controller Card. The ports can be accessed using a
standard CAT 5 cable with an RJ-45 connector. The pin assignments for the RJ-45
connectors are listed in the Ethernet Pin List.
WARNING: The Ethernet Port interfaces MUST NOT be metallically connected to
interfaces that connect to the Outside Plant (OSP) or its wiring. These
interfaces are designed for use as intra-building interfaces only. The
addition of primary protectors is not sufficient protection in order to connect
these interfaces metallically to OSP wiring.
OPERATIONAL SPECIFICATIONS
Specification Description
Input Voltage –48 VDC Systems: –42 VDC to –60 VDC
–24 VDC Systems: –22 VDC to –27 VDC
+24 VDC Systems: +22 VDC to +27 VDC
Temperature Operation: –40°C to +65°C
Storage: –40°C to +85°C
Relative Humidity Up to 95% noncondensing
61189902L1-22A
0512
MX3112 Controller Card
B
A
MX3 4-Port Ethernet ModuleMX3 Fan Module
*61189902L1-22A*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61189902L1-22A
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
.
MX3 4-PORT 10/100BASE-T ETHERNET MODULE
INSTALLATION
After unpacking the unit, inspect it for damage. If damage has occurred, file a claim with the
carrier and then contact ADTRAN Customer Service. For more information, refer to the
warranty.
This MX3ETH4 Module occupies module slot
A in the MX3 Chassis. Follow the steps listed
below to install the MX3ETH4 module.
1. If installed, remove the Blank Plug (P/N 1189006L1) from the module slot.
2. Pull the ejector latch at the left side of the MX3ETH4 Module front panel from the
latched or closed position.
3. Gently, but firmly, slide the MX3ETH4 Module into module slot
A taking note of the left
and right guide grooves in the MX3 Chassis. Simultaneously, apply thumb pressure at the
left (on the ADTRAN logo) and right (to the right of
PORT 4) of the MX3ETH4 Module
to ensure a good seat of the MX3ETH4 Module pins into the backplane connector.
4. Push the ejector latch against the front panel until it latches.
B
A
1 / 1

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Ask the document