ADTRAN MX3208 Job Aid

Type
Job Aid
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
MX3208
Controller Card
P/N: 1189002L1
CLEI: M3C3EG9A_ _
MX3208 CONTROLLER CARD
LED STATUS FOR ACTIVE CONTROLLER
ACT ! Green .....................Normal (All OK)
!/! Green/Amber.........Normal and console open
(Alternating)
4 Red (Flashing) .......Card has failed
! Amber....................Software update in progress
!/! Red/Amber ............Card has failed and console open
(Alternating)
ALM ! Green .....................No critical, major, or minor alarms
! Red.........................Major or minor alarm in progress
4 Red (Flashing) .......Critical alarm in progress
DS3 A/B ! Green .....................Normal (DS3 OK)
! Red.........................AIS, OOF, RAI, or Idle
4 Red (Flashing) .......DS3 LOS
4 Red (Flashing ........Single/Burst DS3 code violations during previous second
once per event)
!/! Red/Green..............DS2 OOF
(Alternating)
! Amber ....................In test (locally originated)
4 Amber (Flashing) ..In test (remotely originated)
DSX-1 STAT " Off..........................All DSX-1 drops are disabled
! Green .....................Enabled DSX-1 drops Normal (All OK)
! Red.........................Non-critical alarm (AIS) on an enabled DSX-1 drop
4 Red (Flashing) .......LOS on an enabled drop
4 Red (Flashing ........Single/Burst RX DSX-1 code violations during previous
once per event) second
DSX-1 Test " Off..........................No DSX-1 tests in progress
4 Red (Flashing ........Single/Burst pattern errors on drop in test
once per event)
! Amber ....................In test (locally originated)
4 Amber (Flashing) ..In test (remotely originated)
LED STATUS FOR STANDBY CONTROLLER
ACT 4 Green (Flashing)....Normal (All OK)
! Amber....................Software update in progress
4 Amber (Flashing) ..Not ready or software mismatch
4 Red (Flashing) .......Card failure
ALM " Off..........................Permanent state during standby
DS3 A/B " Off..........................Permanent state during standby
DSX-1 STAT " Off..........................Permanent state during standby
DSX-1 TEST " Off..........................Permanent state during standby
DESCRIPTION
The ADTRAN
®
MX3208 Controller Card is a plug-in unit for the MX3 Chassis that provides eight
DSX-1 drops from up to two DS3s. The remaining DS1s may be routed between the DS3s or to
optional drop modules in the MX3 Chassis. Two MX3208 Controller Cards are used together to
provide a redundant circuit. Features of the MX3208 Controller include:
1:1 redundancy
Hot-swappable
NEBS Level 3 compliance
Optional Fan Module (P/N 1189007L1) not required
INSTALLATION AND TURNUP
Ensure all MX3 Chassis wiring has been completed. The MX3208 Controller Card uses the following
MX3 rear panel connections:
BNC IN/OUT pairs A and B for DS3 A and DS3 B
T/R (IN)/(OUT) Amphenol connectors, pins 1-8 and 33-40 for DSX-1 ports 1-8
AUX INPUTS 1-8 for Auxiliary Alarms 1-4. These pins sense open and closed relay contacts. These
pins are not polarity sensitive.
ALARM CONTACTS for Critical, Major, and Minor alarms
NOTE: For the second and third bulleted items above, see the tables in the Pin Assignments section
on the reverse page.
After unpacking the unit, inspect it for damage. If damage has occurred, file a claim with the carrier,
then contact ADTRAN Customer Service. Refer to the Warranty information at the bottom of the
reverse page.
WARNING: For configurations utilizing a single controller card, the empty controller card slot
must be occupied by an Blank Plug (P/N 1189005L1).
This module occupies a controller slot in the MX3 Chassis (P/N 1189001L1). Follow the steps listed
below to install the MX3208 Controller Card.
1. Pull the ejector latches at the left and right sides of the Controller Card front panel from their
latched or closed positions.
2. Gently, but firmly, slide the Controller Card into the upper or lower Controller Card slot taking note
of the left and right guide grooves in the chassis. Simultaneously, apply thumb pressure at the left
(on the ADTRAN logo) and right (on the part number) of the Controller Card to ensure a good seat
of the Controller Card pins into the backplane connector.
3. Push the ejector latches to the left/right against the front panel until they latch.
4. The Controller Card initializes and begins a self-test upon insertion into an active MX3 Chassis.
When the self-test completes the LEDs will reflect the true state of the Controller Card.
61189002L1-22B
0502
*61189002L1-22B*
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61189002L1-22B
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
.
MX3208 CONTROLLER CARD
FRONT PANEL SWITCH
CONNECT AND LOGON
Use the front panel RS-232 DB-9 connector on the active controller to provision the MX3208 system
via VT100 terminal or VT100 terminal emulation software such as HyperTerminal or ProComm
Plus.
Provision terminal port as follows:
Data Rate: any up to 115200 bps
Asynchronous Data Format: eight data bits, no parity (none), one stop bit, and no flow control
The default username and password are ADMIN and PASSWORD in all caps.
PIN ASSIGNMENTS
WARNING: The T/R (DSX-1) interfaces MUST NOT be metallically connected to interfaces which
connect to the Outside Plant or its wiring. These interfaces are designed for use as
intra-building interfaces only. The addition of Primary Protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
QUICK SETUP MENU
To simplify the installation process, all of the basic configuration options necessary to get the MX3208
running are grouped together on the Quick Setup menu.
After installing the unit and successfully logging on, the Main menu will appear. Select option 3,
Quick
Setup.
The Quick Setup screen allows configuration of such items as DSX-1 drop assignments, module DS1
assignments if they are installed, as well as system date, time, and IP address information.
To enable a DSX-1 drop (T/R on the Amp Connector), select the appropriate DS1 Port (Options 1-8)
and then select the tributary DS1 (DS3 and its associated DS1).
ACO
Depress to disable any audible alarms only. Any active visual alarms will remain active.
T/R (IN)/(OUT) Amp Connector Pin List
Pin Function Pin
1 Ring 1 Tip 1 33
2 Ring 2 Tip 2 34
3 Ring 3 Tip 3 35
4 Ring 4 Tip 4 36
5 Ring 5 Tip 5 37
6 Ring 6 Tip 6 38
7 Ring 7 Tip 7 39
8 Ring 8 Tip 8 40
32 FGND FGND 64
If an optional module is installed, follow the same procedure to connect it to the proper tributary DS1s.
Options 9 - 14 are used to set the system name, date, and time. System IP information can be set as well
so that the Ethernet ports may be used.
COMPLIANCE
The MX3208 Controller Card complies with the requirements covered under UL 60950 and NEBS
Level 3. It is intended to be installed in restricted access areas only.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the users authority to
operate this equipment.
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC)
Installation Code (IC) A
Card: Controller A ADTRAN MX3208 SYSTEM 01/01/00 00:00
Unacknowledged Alarms: NONE ID: Site 1 MX3208
MX3208->Quick Setup
DS1 Ports Module Drops
1 – #1:DS3 A T1 #1 Module A
2 – #2:DS3 A T1 #2
15 - MA1 – DS3 A T1 #28
3 – #3:DS3 A T1 #3
16 - MA2 – DS3 B T1 #28
4 – #4:
5 – #5:
6 – #6:
7 – #7:
8 – #8:
System
9 – System ID : Site 1 MX3208
10 – IP address : 0.0.0.0
11 – SubNet Mask : 0.0.0.0
12 - Gateway : 0.0.0.0 17 – Module Quick Setup Menu
13 – Date : 01/01/2000
14 – Time : 00:00:00
Selection: '?' - System Help Screen
Aux Inputs 1 - 8 Pin List
Aux Inputs Function
1, 2 Alarm 1
3, 4 Alarm 2
5, 6 Alarm 3
7, 8 Alarm 4
  • Page 1 1