Extron MLC 226 IP L Template

Category
Projector mounts
Type
Template

This manual is also suitable for

1MLM 226 Faceplates • Installation Guide
MLM 226 Faceplates Installation Guide
This guide provides instructions for installing the following Extron MediaLink
Mounting Options faceplates, which are designed for use with the MLC 226 IP
MediaLink Controller.
MLM 226 Faceplates
The following MLM 226 faceplates are available for the MLC 226 IP MediaLink
Controller.
The MLM 226 L, MLM 226 3GWP, and MLM 226 5GWP faceplates are shipped
with the MLC 226 IP controller, depending on the controller configuration that is
ordered. The rest of the mounting options described below may be ordered
separately as replacements, or for use with an MLC 226 IP that is ordered without
a faceplate.
MLM 226 LA low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/
furniture-mounting faceplate. This faceplate is required when you are mounting
an MLC 226 IP using an optional UCM RAAP or UCM 10X8P mounting kit.
Part numbers: 70-342-02 (black), 70-342-03 (white), 70-342-05 (RAL9010 white)
MLM 226 LAAPA low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)
lectern/furniture-mounting faceplate with an opening that accommodates four
single-space AAPs
Part numbers: 70-343-02 (black), 70-343-03 (white), 70-343-05 (RAL9010 white)
MLM 226 3GWP — A three-gang (4.50" H x 6.40" W [11.43 cm H x 16.26 cm W])
faceplate that can be mounted to a mud ring (mounting bracket), an Extron
Surface Mount Box, an Extron External Wall Box, or a standard electrical box
Part numbers: 70-376-02 (black), 70-376-03 (white), 70-376-05 (RAL9010 white)
68-919-01, Rev. C
10 05
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 FaceplatesInstallation Guide2
MLM 226 5GWP — A five-gang (4.50" H x 10.13" W [11.43 cm H x 25.73 cm W])
faceplate with an opening that accommodates four single-space AAPs. It can
be mounted to a mud ring, an Extron Surface Mount Box, an Extron External
Wall Box, or a standard electrical box.
Part numbers: 70-377-02 (black), 70-377-03 (white), 70-377-05 (RAL9010 white)
MLM 226 7GWP A seven-gang (4.50" H x 13.75" W [11.43 cm H x
34.46 cm W]) faceplate with two openings that accommodate four single-space
AAPs each (eight AAPs total). It can be mounted to a mud ring, an Extron
Surface Mount Box, an Extron External Wall Box, or a standard electrical box.
Part numbers: 70-340-02 (black), 70-340-03 (white), 70-340-05 (RAL9010 white)
Replacing an MLC 226 IP Faceplate with an MLM Faceplate
1. Using a small Phillips screwdriver, remove the four faceplate attachment screws
(marked
1
in the diagram below), and save them for later use.
CAUTION
Do not remove these screws while the MLC is installed in a wall or
furniture, or the controller may fall down into the wall or furniture.
Extron
MLC 226 IP
PROJECTOR
1
2
3
4
5
6
VOLUME
CONFIG
IR
ON
OFF
AUTO
IMAGE
MUTE
LAPTOP
VCR
DVD
AUX
VIDEO
PC
1
1
1
1
3MLM 226 Faceplates • Installation Guide
2. Lift the faceplate off the MLC 226 IP, as shown below.
O
F
F
O
N
LAPTOP
PC
VCR
DVD
AUX
VIDEO
MUTE
AUTO
IMAGE
E
xtron
PROJECTOR
1
2
3
4
5
6
VO
L
UM
E
C
O
N
F
IG
IR
MLC
226
IP
3. Align the openings in the new MLM faceplate with the controller’s buttons,
knob, and LEDs, then place the new faceplate on the MLC 226 IP.
4. Replace the four screws removed in step 1, and hand tighten them.
5. Install the MLC 226 IP controller with the MLM 226 faceplate in a wall or
furniture as appropriate.
If necessary, use the measurements given on the appropriate template in the
next section as guidelines for drawing the rectangle that you will cut out of
the installation surface to mount the controller with its faceplate. (Refer to
your MLC 226 IP user’s manual for detailed instructions on preparing the
mounting site.)
Templates
Use one of the following templates as a guide to measure and mark the hole for
installing the MLM 226 faceplate with an attached MLC 226 IP.
CAUTION
These templates are not to scale. Use the dimensions shown in the
templates as reference guidelines for measuring and drawing the rectangle
that will be cut out.
The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall or
furniture.
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 FaceplatesInstallation Guide4
MLM 226 L template
6.5"
(16.5 cm)
Cut-Out Template for Extron's MLM 226 L and MLC 226 IP L
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP
and MLM 226 L
directly into furniture,
cut along this line.
Top Panel
2.9"
(7.4 cm)
5.4"
(13.7 cm)
SURFACE CUT-OUT AREA
FOR FURNITURE MOUNT
3.15"
(8.0 cm)
Location of MLC 226 IP
.295"
(0.75 cm)
(4 places)
.250"
(0.64 cm)
(4 places)
5MLM 226 Faceplates • Installation Guide
MLM 226 LAAP template
.250" (0.64 cm)
2.9"
(7.4 cm)
8.9"
(22.6 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
10"
(25.4 cm)
Cut-Out Template for Extron's MLM 226 LAAP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP
and MLM 226 LAAP
directly into furniture,
cut along this line.
Top Panel
Location of MLC 226 IP
3.15"
(8.0 cm)
.295" (0.75 cm)
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 FaceplatesInstallation Guide6
MLM 226 3GWP template
6.4"
(16.26 cm)
Cut-Out Template for Extron's MLM 226 3GWP and MLC 226 IP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP
and MLM 226 3GWP
directly into furniture,
cut along this line.
Top Panel
2.9"
(7.4 cm)
5.4"
(13.7 cm)
SURFACE CUT-OUT AREA
FOR FURNITURE MOUNT
4.5"
(11.4 cm)
Location of MLC 226 IP
7MLM 226 Faceplates • Installation Guide
MLM 226 5GWP template
2.9"
(7.4 cm)
8.9"
(22.6 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
10.13"
(25.73 cm)
Cut-Out Template for Extron's MLM 226 5GWP and MLC 226 IP AAP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP
and MLM 226 5GWP
directly into furniture,
cut along this line.
Top Panel
Location of MLC 226 IP
4.5"
(11.4 cm)
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 FaceplatesInstallation Guide8
© 2005 Extron Electronics. All rights reserved.
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500
Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400
Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building
16 Ichibancho
Chiyoda-ku, Tokyo 102-0082 Japan
+81.3.3511.7655
Fax +81.3.3511.7656
www.extron.com
MLM 226 7GWP template
2.9"
(7.4 cm)
12.9"
(32.8 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
13.565"
(34.46 cm)
Cut-Out Template for Extron's MLM 226 7GWP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP
and MLM 226 7GWP
directly into furniture,
cut along this line.
Top Panel
Location of MLC 226 IP
4.5"
(11.4 cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Extron MLC 226 IP L Template

Category
Projector mounts
Type
Template
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI