Extron MLM-WB+ User manual

Type
User manual

This manual is also suitable for

User Guide
MLM-WB+
Architectural Mounting Frames
Lockable Metal Wall Box
68-609-01 Rev. E
04 13
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier
du produit d’une tension électrique dangereuse susceptible de
provoquer un choc électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron,
réf. 68-290-01, sur le site Extron, www.extron.fr.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.de.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro
del producto, lo que puede representar un riesgo de descarga
eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso
y mantenimiento recogidas en la documentación proporcionada
con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.es.
Chinese Simplified(简体中文)
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危
电 压 ,有 触 电 危 险
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、
EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问
Extron 网站 www.extron.cn,参见 Extron
安全规范指南,产品编号
68-290-01
Chinese Traditional(繁體中文)
警告: 若產品上使用此符號是為提醒使用產品機殼內存
能會導致觸電之風險的未絕緣危險電壓
意 若產品上使用此符號是為提醒使用者
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳細
資訊,請瀏覽 Extron 網站:www.extron.cn,然後參閱《Extron 安全性與法規
遵守手冊》,準則編號 68-290-01。
Japanese
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない圧がれ、電の険があるこていま
注意: この が製品上に表示されている場合は、本機の取扱説明書に
されている重要な作と保()示についてユーザー
注意を喚起するものです
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.jpより
Extron Safety and Regulatory Compliance Guide(P/N 68-290-01) をごくだ
Korean
경고: 이 기호 , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 , 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
전 가이드라인, 규제 준수, EMI/EMF 호성, 접근성, 그리고 관련
목에 대한 자세한 내용은 Extron 웹 사이트(www.extron.co.kr)의
Extron 안전 및 규제 준수 안내서, 68-290-01 조을 참조하십시오.
Safety Instructions
Inside front cover
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause interference;
the user must correct the interference at his own expense.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide” on the Extron website.
Copyright
© 2013 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
(R)
, registered service marks
(SM)
, and trademarks
(TM)
are the property of RGB Sys-
tems, Inc. or Extron Electronics:
Registered Trademarks (®)
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field,GlobalViewer, Hideaway, Inline, IP Intercom,
IP Link, Key Minder, LockIt, MediaLink, PoleVault, PowerCage, PURE3, Quantum, SoundField, System Integrator, TouchLink, V-Lock,
VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall
Registered Service Mark(SM) : S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), AIS (Advanced Instruction Set), Auto-Image, CDRS (Class D
Ripple Suppression), DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator,
DSVP (Digital Sync Validation Processing), FastBite, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, ProDSP, QS-FPC (QuickSwitch
Front Panel Controller), Scope-Trigger, SIS, Simple Instruction Set, Skew-Free, SpeedMount, SpeedNav, SpeedSwitch, Triple-Action
Switching, XTP, XTP Systems, XTRA, ZipCaddy, ZipClip
Conventions Used in this Guide
Notifications the following are used:
WARNING: A warning indicates a situation that has the potential to result in death or
severe injury.
CAUTION: A caution indicates a situation that may result in minor injury.
ATTENTION: Attention indicates a situation that may damage or destroy the
product or associated equipment.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
vMLM-WB+ • Contents
Contents
Introduction ...................................................1
About this Guide................................................ 1
About the MLM-WB+ ........................................ 1
Features Diagram .............................................. 2
Installation ..................................................... 3
Installation Overview ......................................... 3
Accessibility Requirements ............................... 4
UL Requirements ........................................... 4
ADA Requirements ........................................ 4
Recommended Installation ............................ 6
Components, Hardware, and Required
Tools ................................................................. 7
Main MLM-WB+ Components ...................... 7
Included Mounting Hardware ........................ 7
Required Tools ............................................... 8
Adjusting the Door Angle .................................. 8
Mounting the MLM-WB+
................................... 9
Selecting a Mounting Location ...................... 9
Mounting the MLM-WB+ on a Masonry
Wall ............................................................... 9
Mounting the MLM-WB+ on a
Nonmasonry Wall ....................................... 11
Routing Cables into the MLM-WB+ ................ 13
Installing the Junction Box .......................... 13
Installing AV and Control Cables ................. 14
Installing Equipment ........................................ 15
Installing and Cabling Equipment in the
2U Rack Enclosure ..................................... 15
Installing and Cabling Equipment in the
4U Rack Enclosure ..................................... 16
Testing the Installation ..................................... 18
Completing the Installation.............................. 18
Adjusting the Door Lock .................................. 20
Ordering Additional or Replacement Keys ...... 20
MLM-WB+ • Contents
vi
MLM-WB+ • Introduction 1
1
Introduction
This section gives an overview of the capabilities of the Extron MLM-WB+ wall box and
provides a diagram of its features. The following topics are covered:
• About this Guide
• About the MLM-WB+
• Features Diagram
About this Guide
This guide contains a description and specications of the MLM-WB+ wall box and
provides installation instructions.
About the MLM-WB+
The Extron MLM-WB+ is a locking metal wall box with two enclosures for mounting
Extron controllers and audio-video (AV) equipment.
The upper, 2U rack enclosure can hold Extron mounting frames and faceplates for
mounting Architectural Adapter Plates (AAPs) and control pads such as the
MediaLink 226 IP. Alternatively, Extron quarter-rack width products that are 3 inches
(7.6 cm) deep can be mounted in this space using an Extron 3.5 inches deep rack shelf.
The lower, 4U rack enclosure can hold a VCR, DVD player, rack-mountable switcher,
or other rack-mountable equipment. The top of the enclosure also provides a stable
platform for a laptop or other small, portable device.
The MLM-WB+ can be installed on masonry walls, walls with wood or aluminum studs,
and walls with a combination of solid and hollow areas.
WARNINGS: Risk of Severe Bodily Injury:
Do not sit on or lean against the door or 4U rack enclosure.
When properly installed, the open 4U door can hold up to 150 pounds (68 kg).
For safety considerations, Extron recommends that no more than 15 pounds
(7 kg) be placed on top of the open door.
MLM-WB+ Series • Introduction 2
Features Diagram
Figure 1 shows the parts of the MLM-WB+.
PROJECT
OR
1
2
3
4
5
6
VOLUM
E
CONFIG
IR
PC
A
UX
VIDEO
DVD
VCR
LAP
TOP
AUTO
IMAGE
MUTE
ON
OFF
MLC 226 IP L
DVD-RW/-R RECORDING
Precision Cinema Progressive
MLS 406MA
MediaLink Switcher
CONTROL
PEAK
CLIP
SIGNAL
INPUT SELECT
1
2
3
4
5
6
DVD Player
Cam Lock
4U Rack Enclosure
MediaLink Switcher
MLC 226 IP L
AAPs
UCM RAAP
Figure 1. The MLM-WB+ Wall Box
MLM-WB+ • Installation
3
Installation
This section contains instructions for installing the MLM-WB+ and for connecting cables
to equipment in the wall box. The following topics are discussed:
• Installation Overview
• Accessibility Requirements
• Components, Hardware, and Required Tools
• Adjusting the Door Angle
• Mounting the MLM-WB+
• Routing Cables into the MLM-WB+
• Installing Equipment
• Testing the Installation
• Completing the Installation
• Adjusting the Door Lock
• Ordering Additional or Replacement Keys
Installation Overview
WARNINGS: Risk of Severe Bodily Injury:
Do not sit on or lean against the door or the 4U rack enclosure.
For safety considerations, Extron recommends that no more than 15 pounds (7
kg) be placed on top of the open door.
ATTENTION: Potential Damage to Property: All installation and service
procedures should be performed by a qualied Extron installer or an electrician.
Extron is not responsible for equipment failure or damage occurring as a result of
an improper installation.
NOTE: Contact a contractor or hardware specialist for assistance with the
installation. Your installation may require additional hardware beyond what Extron
provides with the MLM-WB+.
Identify components and mounting hardware for the MLM-WB+ and obtain the tools
required for installation (see Components, Hardware, and Required Tools on
page 7).
1. Select the installation site. On nonmasonry walls, the MLM-WB+ must be attached
to at least one stud. The recommended installation suggests that the wall box be
attached to two wall studs or to a concrete or masonry wall.
2. Mount the outer enclosure onto the wall, and route power cables of the electrical
devices into the junction box inside the MLM-WB+.
3. Wire power cables to the duplex receptacles, and secure the receptacles and
junction box cover to the junction box.
MLM-WB+ • Installation
4
4. Route the audio, video, control, and power cables of the electrical devices through
the small rectangular openings on top of the MLM-WB+. Remove the left and right
side panels and continue routing these cables to the lower part of the enclosure (see
Routing Cables into the MLM-WB+ on page 13).
5. Install all devices into the MLM-WB+ 2U and 4U rack enclosures. To do this,
perform the setup procedure (if applicable) for each AV device to be installed and
then connect power and AV cables to all equipment (see Installing Equipment on
page 15).
6. Test all installed equipment. Make adjustments to settings and cabling as needed.
Be sure to disconnect power from all electrical devices before making wiring
changes.
WARNING: Risk of Electric Shock. Disconnect power from the computer, all
input and output devices, and any controllers before adjusting the wiring.
7. Secure all equipment in the 2U and 4U rack enclosures.
Accessibility Requirements
Keep the following safety and accessibility requirements in mind when choosing an
installation location and method.
UL Requirements
The Underwriters Laboratories (UL) requirements listed below pertain to the installation
of an MLM-WB+ wall box.
• Power supplies used with devices such as an MLC must be secured in the
MLM-WB+ with the flat side down.
• You must use a UL-listed junction box.
NOTE: The UL-listed electrical box (junction box) is included with the MLM-WB+.
• This unit must be installed in accordance with the National Electrical Code and with
all local codes.
NOTE: For specific and location-based requirements, contact UL
(1-877-ULHELPS or www.ul.com) or a UL specialist.
ADA Requirements
The following Americans with Disabilities Act (ADA) requirements pertain to the
installation of the MLM-WB+ into a masonry or non-masonry wall. ADA compliance is a
legal requirement in most of the U.S., and is intended to ensure safety for the disabled
while they are moving about public places. For specic requirements in your area,
contact an ADA specialist (see the note below for contact information).
NOTE: For specific and location-based requirements, contact the ADA
(1-800-514-0301 or www.ada.gov) or an ADA specialist.
MLM-WB+ • Installation
5
The MLM-WB+ must be mounted with the bottom edge at a maximum of 27 inches
(68.6 cm) above the nished oor. This regulation was created to ensure that the blind
or visually impaired, using a cane or guide animal, will be able to detect the MLM-WB+
without collision.
27” (68.6 cm)
or lower
Extron
MLM-WB+
MediaLink Wall Box
Figure 2. MLM-WB+ as a Protruding Object Along a Wall
The topmost controls of devices housed in the MLM-WB+ must be 48 inches (122 cm)
or less from the nished oor. This regulation was proposed so that a person in a
wheelchair has access to the controls with a maximum side reach of 48 inches (122 cm).
48" (122 cm)
Extron
MLM-WB+
MediaLink Wall Box
or lower
Figure 3. Wheelchair Access to the MLM-WB+
MLM-WB+ • Installation
6
Recommended Installation
The following illustrates the recommended placement of the MLM-WB+. It complies with
the safety and accessibility ADA requirements for most locations.
18.5" (47.0 cm)
3.0" (7.6 cm)
7.5" (19.0 cm)
21.0" (53.3 cm)
Per ADA Requirements for
Blind or Visually Impaired
50.0" (127 cm)
Overall Height
48.0" (122.0 cm) Max
Height for Control
Buttons per Wheelchaired
ADA Requirements
Figure 4. MLM-WB+ Installation Dimensions
NOTE: To meet ADA requirements for the blind and visually impaired and to allow space for all
components to function properly, mount the MLM-WB+ with the bottom edge 21 inches (53.3 cm) up
from the finished floor.
MLM-WB+ • Installation
7
Components, Hardware, and Required Tools
The illustrations in this section identify the components of the MLM-WB+ and the
mounting hardware provided with it. Also included is a list of tools required to perform
the installation. The installation steps in this section refer to these components,
hardware, and tools.
Main MLM-WB+ Components
Adjustable Clamp Brackets
Extension Damper
12" (30.5 cm) and 16" (40.6 cm)
OC Spaced Mounting Slots
Cable Opening (2 per side)
Cable Tie Holes
Removable Side Panel
(to access cable channel)
Clevis Bracket
(for door leveling adjustment)
Rubber Stop
4U Rack Enclosure
Work Space/
Equipment Cover (Max. 15 lb [7 kg])
2U Rack Enclosure
Figure 5. MLM-WB+ Main Components
Included Mounting Hardware
The following mounting hardware is included with the MLM-WB+:
(6) 1/4" x 1 3/4" Masonry Screws
#40-373-01
(6) 1/4" x 1" O.D., 5/16"
I.D. Metal Washers #40-376-01
(6) #14 x 1 3/4" Self-tapping
Metal/Wood Screws #40-372-01
(4) 1/4-20 x 2"
Pan Head Bolts
#40-375-01
(4) 1/4" Kap Toggle
Assemblies #40-374-01
Figure 6. Mounting Hardware
MLM-WB+ • Installation
8
Required Tools
To install the MLM-WB+ you need the following tools:
• Phillips screwdriver Pencil
• Flat head screwdriver 3/8-inch wrench or ratchet
• Drill with drill bits Wire cutter
• Level
Adjusting the Door Angle
Before mounting the MLM-WB+, ensure that the door opens to a 90º angle. To adjust the
door angle:
1. Set the MLM-WB+ upright on a flat surface and open the door.
CAUTION: Risk of Bodily Injury: If not properly secured in place, the
MLM-WB+ can potentially fall forward.
2. Remove the screws holding the clevis brackets to the door.
3. Slide the clevis brackets:
• Forward, to make the door open to a higher position, or
• Backward, to make the door open to a lower position.
Figure 7. Sliding the Clevis Brackets to Adjust the Door Angle
4. Align the holes on the clevis bracket with the holes on the door.
5. Replace the screws that were removed in step 2.
MLM-WB+ • Installation
9
Mounting the MLM-WB+
The procedures in this section enable you to securely mount the MLM-WB+ to a
masonry or nonmasonry wall. These procedures assume that you have already
unpacked the MLM-WB+ and installed necessary cables into the wall or conduits in
conformance with local and national electrical codes and equipment size requirements.
ATTENTION: Potential Damage to Property: All installation and service
procedures should be performed by a qualied Extron installer or an electrician.
Extron is not responsible for equipment failure or damage occurring as a result of
an improper installation.
NOTE: Review UL and ADA mounting and installation requirements (see
Accessibility Requirements on page 4).
WARNING: Risk of Severe Bodily Injury. The MLM-WB+ weighs approximately
63 pounds (29 kg) without equipment installed. To avoid injury, use at least two
individuals to unpack and mount the MLM-WB+, following, as a minimum, these
safe lifting and moving guidelines:
Avoid lifting with your back.
Use both hands to hold the MLM-WB+.
Avoid unnecessary reaching, bending, or twisting.
Selecting a Mounting Location
When determining a mounting location for the MLM-WB+, consider the following factors:
• Type of wall — This section contains installation instructions for both masonry and
nonmasonry walls. In addition, the thickness of the wall and the accessibility of wall
studs determine the number of mounting holes to be used and whether toggle bolts
are required.
• Adequate clearance on all sides of the MLM-WB+ — Keep in mind that when
fully lowered, the door extends out about 20.5 inches (52 cm) from the front of the
MLM-WB+. Sufficient space is also required on each side of the
MLM-WB+ to remove the side panels, to route cables, and to access the rear panel
of any AV device mounted in the 2U rack enclosure.
• Proximity of the MLM-WB+ to installed cables — For example, if you plan to
route cables from the wall into the opening in the back of the MLM-WB+, you should
prepare the cables and position the MLM-WB+ accordingly.
Mounting the MLM-WB+ on a Masonry Wall
To mount the MLM-WB+ onto a brick, stone, or concrete wall:
1. With the help of at least one other person, hold the MLM-WB+ against the wall and
use a carpentry level or similar tool as a guide for leveling the unit.
2. Mark at least six locations for masonry screws to ensure the strength and stability of
the installation. As shown in figure 8 on the next page, mark four positions to line
up with slotted mounting holes on the MLM-WB+ enclosure and two positions to
line up with round mounting holes (indicated by + marks).
3. Set the MLM-WB+ aside.
MLM-WB+ • Installation
10
FIG_Mounting hole locations
4.
MLM-WB+ mounting 4corners.eps
Figure 8. MLM-WB+ Mounting Hole Locations (Viewed from the Front)
NOTE: To more clearly indicate where mounting holes should be marked, the rear
panel of the MLM-WB+ is shown.
5. Using a masonry drill bit, drill pilot holes in the wall at the locations you marked in
step 2; make the holes 1.75 inches (4.4 cm) deep.
ATTENTION: Potential Damage to Property. If you make the pilot hole too
shallow, the screw head might break off while it is being fastened into the hole.
6. Install masonry screws in slotted mounting hole locations as follows:
a. Prepare the screw for installation by inserting it through a flat metal washer
(1 inch [2.5 cm] outer diameter and 0.25 inch [0.6 cm] inner diameter).
b. Insert the screw and washer into one of the pilot holes on the wall.
NOTE: At this time, install only the masonry screws that line up with slotted
mounting holes on the MLM-WB+.
c. Securely fasten the screw into the wall until a gap of 1/8 to 3/8 inch (3 to 9 mm)
remains between the wall and the metal washer.
d. Repeat these steps until all masonry screws have been installed for slotted
mounting hole locations.
7. Align the slotted mounting holes ( )
in the back of the MLM-WB+ with the
screws in the wall. Move the MLM-WB+
forward over the washers and down, as
shown at right.
8. Insert a masonry screw and washer
through each round mounting hole on the
MLM-WB+ enclosure for which you drilled
a pilot hole.
9. Tighten all masonry screws to secure the unit to the wall.
+
AB
+
MLM-WB+ • Installation
11
Mounting the MLM-WB+ on a Nonmasonry Wall
NOTE: On nonmasonry walls, the MLM-WB+ must be attached to at least one stud.
The recommended installation suggests that the wall box be attached to two wall
studs or to a concrete or masonry wall.
1. Locate the wall studs in the area where you will install the MLM-WB+, and use a
pencil to mark their locations on the wall.
2. With the help of at least one other person, hold the MLM-WB+ against the wall so
that the mounting holes line up with the studs as follows:
• If two wall studs are accessible, align the slotted and round mounting holes
on the back of the MLM-WB+ with the studs as shown in figure 9 (choose either
option A or option B).
• If only one wall stud is accessible, align the round mounting hole in the
center of the MLM-WB+ with the stud (option C in figure 9).
12" (30.5 cm)16" (40.6 cm)
Level
A
BC
Figure 9. Options for Securing the MLM-WB+ to Wall Studs (View of Rear
Panel as Seen from the Front)
3. Use a carpentry level or similar tool as a guide for leveling the unit.
4. When the MLM-WB+ is level and properly aligned with the studs, mark the locations
of the slotted and round mounting holes on the MLM-WB+ (indicated by + marks in
figure 9).
If you are mounting the MLM-WB+ to only one stud (option C in gure 9) also mark
the slotted holes indicated by the four X marks to add toggle bolts to increase the
stability and strength of the installation.
5. Set the MLM-WB+ aside.
6. Drill pilot holes in the wall at the locations you marked in step 4.
• If drilling into a stud, make each hole 1.75 inches (4.4 cm) deep.
• If drilling into the wall where no stud is present, make each hole
through to the hollow part of the wall.
MLM-WB+ • Installation
12
7. Install a self-tapping screw and washer in each slotted mounting hole ( ) location
lined up with a wall stud:
a. Prepare the screw for installation by inserting it through a flat metal washer (1
inch [2.5 cm] outer diameter and 0.25 inch [0.6 cm] inner diameter).
b. Insert the screw and washer into one of the pilot holes on the wall.
NOTE: At this time, install only screws that line up with slotted mounting holes
on the MLM-WB+.
c. Securely fasten the screw into the wall until a gap of 1/8 inch to 3/8 inch
(3 to 9 mm) remains between the wall and the metal washer.
d. Repeat these steps until all self-tapping screws have been installed for slotted
mounting hole locations.
8. Install toggle bolts (if required) as follows:
a. While holding the plastic handle, collapse the toggle assembly and insert it into
the wall through one of the pilot holes.
b. Secure the toggle assembly by sliding the plastic washer down the plastic
handle into the pilot hole in the wall.
c. Using a cutting tool, cut off the plastic handle close to the plastic washer in the
wall. The plastic washer creates a threaded hole for a toggle bolt.
d. Insert a pan head bolt through a metal washer, then into the threaded hole,
leaving a gap of 1/8 to 3/8 inch (3 to 9 mm) between the washer and the wall.
a. b.
c. d.
Figure 10. Installing Toggle Bolts
ATTENTION: Potential Damage to Property. Install the toggle bolt
by hand; do not use a power tool. A power tool may create too much
pressure, causing the plastic washer of the toggle assembly to break. If
this happens, the assembly will fall into the wall.
e. Repeat these steps until all toggle bolts have been installed.
MLM-WB+ • Installation
13
9. Align the slotted mounting holes ( )
in the back of the MLM-WB+ with the
screws or toggle bolts in the wall. Move
the MLM-WB+ forward over the washers
and down as shown at right.
10. Insert a self-tapping screw and washer
into each round mounting hole on the
MLM-WB+ enclosure for which you drilled a pilot hole.
11. Tighten the screws and toggle bolts to secure the MLM-WB+ to the wall.
Routing Cables into the MLM-WB+
After the MLM-WB+ is securely mounted to the wall, route all power, audio, video, and
control cables required for the installation.
ATTENTION: Potential Damage to Property. All electrical installation steps
should be performed by a qualied electrician in accordance with national and
local electrical codes.
Installing the Junction Box
Extron recommends using the UL-listed junction box and receptacles included with
the MLM-WB+. In some cases, such as installations in Europe and Asia, you may need
to use a different kind of junction box and receptacles to meet local electrical code
requirements.
WARNING: Risk of Electric Shock. Improperly grounded or ungrounded
receptacles can allow electrical shocks, which can cause injury and damage
equipment. Receptacle installation should only be performed by a qualied
electrician in accordance with national and local electrical codes.
1. Remove a knockout tab from one of the openings in the junction box.
• Remove a rear knockout tab if the power cable will be routed in from behind the
MLM-WB+.
• Remove one of the top or left conduit knockouts if the power cable will be
inserted via a conduit through the top or bottom of the MLM-WB+.
2. If needed, install a 1.125 inch (2.9 cm) or 1.375 inch (3.5 cm) outer diameter conduit
through one of the knockouts at the top or bottom of the MLM-WB+ enclosure. Use
standard fittings to secure it to the junction box inside the MLM-WB+.
NOTE: The installer is responsible for providing the conduit and fittings; Extron
does not provide these items.
3. Install receptacles into the junction box as follows:
a. If necessary, cut off the mounting strap tabs (ears) of the receptacles so that
the fronts of the receptacles fit snugly against the back side of the junction box
cover.
b. Secure each duplex receptacle to the junction box cover.
+
AB
+
MLM-WB+ • Installation
14
Installing AV and Control Cables
This section explains how to route AV and control cables through the MLM-WB+.
NOTE: To reduce electromagnetic interference, route the AV and control cables
separately from the power cables.
1. Remove the right, left, or both side panels from the MLM-WB+ by loosening the nuts
on the inside of the unit and then pushing the panels out. Set the panels aside.
Loosen nut
to remove
side panel.
Figure 11. Removing the MLM-WB+ Side Panels
2. Feed the AV cables through the small rectangular openings in the right side panel to
route cables to and from the 4U and 2U rack enclosures.
3. Route the AV and control cables through the opening in the rear panel or through the
top or bottom of the enclosure through the knockout.
If you route cables through the top or bottom of the MLM-WB+, install a conduit or
raceway through a knockout. Allow enough cable inside the MLM-WB+ to permit the
door to open fully when cabled equipment is installed.
NOTE: The installer is responsible for providing the conduit and fittings; Extron
does not provide these items.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Extron MLM-WB+ User manual