Wavetronix Click 100 User guide

Category
Network switches
Type
User guide
Click 100–400 Series
USER GUIDE
Click 100–400 Series
USER GUIDE
www.wavetronix.com 78 East 1700 South Provo, Utah 84606 801.734.7200
© 2015 Wavetronix LLC. All Rights Reserved.
Wavetronix, SmartSensor, Click, Command, and all associated product names and logos are trademarks of Wavetronix LLC. All other
products or brand names as they appear are trademarks or registered trademarks of their respective holders.
Protected by US Patent Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,889,098; 7,924,170; 7,991,542;
8,248,272; 8,665,113; Canadian Patent Nos. 2461411; 2434756; 2512689; and European Patent Nos. 1435036; 1438702; 1611458. Other
US and international patents pending.
e Company shall not be liable for any errors contained herein or for any damages arising out of or related to this document or the
information contained therein, even if the Company has been advised of the possibility of such damages.
is document is intended for informational and instructional purposes only. e Company reserves the right to make changes in the
specications and other information contained in this document without prior notication.
FCC Part 15 Compliance: e Wavetronix SmartSensor sensors comply with Part 15 of the Federal Communications Commission
(FCC) rules which state that operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesirable operation. FCC compli-
ance statements for applicable optional modules are to be found in the module specications. Unauthorized changes or modications
not expressly approved by the party responsible for compliance with the FCC rules could void the user’s authority to operate this
equipment.
Disclaimer: e advertised detection accuracy of the Wavetronix SmartSensor sensors is based on both external and internal testing,
as outlined in each products specication document. Although our sensors are very accurate by industry standards, like all other sen-
sor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our tech-
nology. erefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we oer no additional
representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the
accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
WX-500-0055
10/2016
Contents
Introduction 7
Using this Manual 7
Part I Introduction to the Click Series
Chapter 1 The Power Plant 11
Connecting to a Circuit Breaker 12; Connecting AC Surge
Protection 12; Connecting Power 13; Wiring AC Power into
the Click 201/202/204 14
Chapter 2 T-bus Basics 17
Adding a T-bus to the DIN Rail 18; Mounting Click Devices
18; Wiring T-buses 18
Chapter 3 Wiring the Devices 21
Working with Screw Terminal Blocks 21; RS-485 Communica-
tion 22; RS-232 Communication 24
Chapter 4 Installing Click Supervisor 27
Installing Click Supervisor 28; Microso .NET Framework 31
Chapter 5 Using Click Supervisor 33
Connecting to Your Computer 33; Accessing the Communica-
tion Screen 34; Serial Communication 35; IP Communication
37; Working with Modules 38
Part II Individual Click 100–400 Series Modules
Chapter 6 Click 100 — 16 Output Contact Closure 43
Physical Features 44; Troubleshooting 48
Chapter 7 Click 104 — 4-channel DIN Rail Contact Closure 49
Physical Features 50; Installation 52; Conguration 53; Rotary
Switch 54; Front Panel Menu 55; Click Supervisor 61
Chapter 8 Click 110 — 4-channel Contact Closure Eurocard 67
Physical Features 68; Installation and Wiring 70; Fail-safe
Mode 73; Conguration 73; DIP Switches 74; Front Panel
Menu 80; Click Supervisor 89
Chapter 9 Click 112/114 — Detector Rack Cards 95
Physical Features 96; Installation and Wiring 97; Congura-
tion 99; DIP Switches 100; Front Panel Menu 103
Chapter 10 Click 120/121 — Relay 117
Physical Features 118; Installation 118
Chapter 11 Click 200 — Lightning Surge Protector 121
Physical Features 122; Installation 123
Chapter 12 Click 201/202/204 — AC to DC Power Supply 127
Physical Features 128; Installation 128
Chapter 13 Click 203 — UPS/Battery 131
Physical Features 132; Installation 133; On-device Congura-
tion 134
Chapter 14 Click 210 — AC Circuit Breaker 137
Physical Features 138; Installation 138
Chapter 15 Click 211 — AC Outlet 139
Physical Features 140; Installation 140
Chapter 16 Click 221 — DC Surge Protector 143
Physical Features 144; Installation 144
Chapter 17 Click 222 — System Surge Protector 145
Physical Features 146; Installation 147
Chapter 18 Click 223 — Dual-485 Surge Protector 151
Physical Features 152; Installation 153
Chapter 19 Click 230 — AC Surge Protector 155
Physical Features 156; Installation 156
Chapter 20 Click 250 — Wireless Surge Protector 159
Physical Features 160; Installation 160
Chapter 21 Click 301 — Serial to Ethernet Converter 163
Physical Features 164; On-device Conguration 165
Chapter 22 Click 304 — RS-232 to RS-485 Converter 183
Physical Features 184; On-device Conguration 185; Com-
puter Conguration 186
Chapter 23 Click 330 — Unmanaged Switch 195
Physical Features 196; Installation 197; Switching Characteris-
tics 198
Chapter 24 Click 400 — 900 MHz Radio 199
Physical Features 200; On-device Conguration 201; Com-
puter Conguration 203
Chapter 25 Click 421 — Serial to Bluetooth® Radio 215
Physical Features 216; On-device Conguration 217; Com-
puter Conguration 219
In the introduction
Using this Manual
Wavetronix Click products are a simple and cost-eective way to connect various trac
components into a single, unied system. With a broad range of easy-to-use products, the
Click line integrates quickly and operates in even the harshest conditions. Click devices
provide the power and communication solutions needed for eective trac control and
management.
e Click series is divided into ve smaller, numerically based series. Each device in a par-
ticular series shares common elements, functions, etc.:
Click 100 series – Contact closure devices
Click 200 series – Power and surge protection devices
Click 300 series – Wired communication devices
Click 400 series – Wireless communication devices
Click 500 series – Customizable devices built on our Click 500 platform
is user guide covers the Click 100–400 series. For the Click 500 series, please see the Click
500 Series User Guide.
Using this Manual
is manual is divided into two parts:
Part I: Introduction to the Click Series – is part contains information common to
the Click line, beginning with basic module installation guidelines. It then covers the
Introduction
8 INTRODUCTION CLICK 100–400 SERIES USER GUIDE
Click Supervisor soware, which is used with certain Click devices for conguration.
For a list of Click 100–400 series devices that use Click Supervisor, see the beginning
of Chapter 4.
A few Click devices dier from what is written in the common information chapters
in the way they are installed or the soware used to congure them. In the event that a
Click device departs from what is written in Part I, that dierence will be noted in that
devices chapter in Part II.
Part II: Individual Click 100–400 Series Modules – is part contains a chapter for
every device (or set of devices, in some cases) in the Click 100–400 series. Each chap-
ter has an introduction to the device along with a description of the devices physical
features and, when pertinent, sections on installation, conguration, troubleshooting
and more.
Part I
Introduction to the Click Series
Chapter 1 – The Power Plant
Chapter 2 – T-bus Basics
Chapter 3 – Wiring the Devices
Chapter 4 – Installing Click Supervisor
Chapter 5 – Using Click Supervisor
In this chapter
Connecting to a Circuit Breaker
Connecting AC Surge Protection
Connecting Power
1
Power and surge protection are provided to your devices via the Click modules that make
up what is known as the power plant (see Figure 1.1). Assembling the power plant is the rst
step in installing your Click devices.
Black (Ground)
Red (+24 VDC)
Black (Line)
Green (Ground)
White (Nuetral)
Earth
Ground
Figure 1.1 – The Click Power Plant
The Power Plant 1
12 CHAPTER 1 THE POWER PLANT
Note
The power plant will only be used if your cabinet is supplied with AC power. If DC is
coming into your cabinet, you will need the Click 221 DC surge protector, discussed in
Part II.
Connecting to a Circuit Breaker
e rst Click module you will connect is the Click 210, a circuit breaker designed to inter-
rupt an electric current under overload conditions. e breaker is trip-free and can be easily
reset aer a current interruption by pushing the reset button (see the Click 210 chapter for
more information on this device).
To add a Click 210 circuit breaker and switch:
1 Using a rocking motion, mount the Click 210 onto the DIN rail.
2 Make sure the reset button on front of the module is pressed down before wiring.
3 Connect the black (line) wire from the terminal block or from the AC cord into one
side of the module.
4 Connect power out of the other side.
Note
It doesn’t matter which side is power in, as long as the opposite end is power out.
Connecting AC Surge Protection
e next module in the power plant is the Click 230, which provides surge protection to
other modules on the DIN rail (see the Click 230 chapter for more information on this de-
vice). Use these steps to include AC surge protection in your installation:
1 Using a rocking motion, mount the Click 230 onto the DIN rail next to the Click 210.
2 Connect the wire from the Click 210 to the rightmost screw terminal (terminal 5) on
the side of the Click 230 marked IN (see Figure 1.2).
3 Connect the white (neutral) and green (ground) wires from the AC terminal block or
from the AC cord into screw terminals 1 and 3, respectively, also on the side marked
IN.
4 Connect the outgoing neutral and power wires to screw terminals 2 and 6, respectively,
on the side marked OUT.
CHAPTER 1 THE POWER PLANT 13
Figure 1.2 – Click 230 Screw Terminals (labels beneath terminals have been added)
Screw terminals 3 and 4 are directly bonded via the metal mounting foot of the base ele-
ment to the DIN rail. ere is no need for any additional grounding between terminals 3
and 4 and the DIN rail.
Note
If you are using a Click 211 in your installation, the configuration of the power plant
will dier slightly from what is listed in this chapter, starting at this point in the
installation process. See the Click 211 chapter of this manual for more information.
Connecting Power
e nal component of the power plant is the AC to DC converter. e Click line features
several such converters. e Click 201/202/204 are AC to DC power supplies that provide
DC power to every Click product mounted on the DIN rail. e Click 201 provides 1 A, the
Click 202 provides 2 A and the Click 204 provides 4 A.
e screw terminals on the top and bottom of the Click 201/202/204 can be unplugged
from the module, allowing you to pre-wire power before the nal installation. e screw
terminal blocks are red-keyed, allowing the block to plug back into only one specic jack.
Note
If you prefer, instead of the Click 201/202/204, you can use the Click 203, which is a
combination UPS and battery. This set of modules will convert AC to DC and provide
uninterrupted power to your equipment. See the Click 203 chapter in Part II of this
document for more information.
14 CHAPTER 1 THE POWER PLANT
Wiring AC Power into the Click 201/202/204
Use the steps below to properly wire AC power to the top of the Click 201/202/204:
1 Using a rocking motion, mount the Click 202/202/204 to the DIN rail next to the Click 230.
2 Connect the power and neutral wires from the Click 230 into the screw terminals
marked L and N, respectively, on the side of the module marked 100–240V AC In.
Figure 1.3 – Wiring AC Power into the Click 201/202/204
Caution
Make sure power to AC mains is disconnected while wiring the AC input.
Wiring DC Power out of the Click 201/202/204
e screw terminals on the bottom of the devices are slightly dierent. e Click 202 and
204 have a single terminal block, while the Click 201 has two; it doesnt matter which of
the two terminal blocks on the 201 you wire into. Connect one wire for DC power (red is
standard) to a screw terminal marked +. Connect a second wire as a ground wire (black is
standard) to either of the two terminals marked – (see Figure 1.4).
Note
Do not wire into the DCOK terminal; it provides only 20 mA and should only be used
to monitor the power supply.
CHAPTER 1 THE POWER PLANT 15
Figure 1.4 – Wiring DC Power out of the Click 201/202/204
Caution
An authorized electrical technician should perform installation and operation of this
unit. Persons other than authorized and approved electrical technicians should NOT
attempt to connect this unit to a power supply and/or trac control cabinet, as there
is a serious risk of electrical shock through unsafe handling of the power source. Ex-
treme caution should be used when connecting this unit to an active power supply.
In this chapter
Adding a T-bus to the DIN Rail
Mounting Click Devices
Wiring T-buses
2
Now that the power plant is complete, the next step in installing your Click modules is add-
ing a T-bus to your DIN rail. A T-bus is made up of small modules called T-bus connectors
that snap onto your DIN rail to provide power and communication connections to your
Click devices. You can connect together as many T-bus connectors as you need to provide
power and communication to all the Click devices on the rail with only a single wiring con-
nection.
Wavetronix has two varieties of T-bus connectors: green connectors, which conduct both
power and communication, and gray connectors, which only conduct power. Gray T-bus
connectors are used when you don’t want certain devices to communicate with each other.
In such a case, a gray connector placed between the two devices would prevent communica-
tion while still providing power.
Note
Wavetronix removes the communication lines from the gray T-bus connectors it pro-
vides. Gray T-bus connectors obtained from suppliers other than Wavetronix, how-
ever, will still have communication capabilities.
T-bus Basics 2
18 CHAPTER 2 T-BUS BASICS
Adding a T-bus to the DIN Rail
Placing the T-bus on the DIN rail is quick and easy. To attach a T-bus connector to the rail,
simply position the connector over the rail with the male connector pointing to the right.
Hook one arm of the connector over one side of the DIN rail and press the other arm down
over the other side until the connector snaps in place. All the T-bus connectors you connect
together should be facing this direction.
To connect T-bus connectors together, simply slide them toward each other until you hear
them snap into place. To disconnect T-bus connectors, use a small, thin item, like a small
screwdriver, to gently pry the two modules apart.
Mounting Click Devices
To connect a Click device to the DIN rail and T-bus, simply position the device over the T-
bus connector and, using the same rocking motion used to connect the devices in the power
plant, snap the device onto the DIN rail.
Note
Not all Click devices use the T-bus this way. Some devices, such as the 330, 331, 340,
341, 342, and those in the power plant, snap onto the DIN rail but not onto the T-bus.
For more information on how to install these devices, see the appropriate chapters in
Part II of this document.
Wiring T-buses
ere are two ways to provide power to a T-bus: wiring through a Click 200 and wiring
through a 5-screw terminal block.
Wiring through a Click 200
e Click 200 is a surge protection device that can be connected to a sensor. e Click 200
is unique among Click devices because it can take power and communications in through
its screw terminals and send it through any T-bus it is currently mounted on.
To provide power to a T-bus through a Click 200, follow these steps (see Figure 2.1):
1 Connect a Click 200 to a DIN rail and T-bus.
2 Connect the red (+24 VDC) wire from the Click 201/202/204 into the +DC screw ter-
minal on the side of the Click 200 marked PROTECTED.
3 Connect the black (ground) wire from the Click 201/202/204 into any of the terminals
marked GND on the same screw terminal block as the red wire.
CHAPTER 2 T-BUS BASICS 19
Figure 2.1 – Wiring Power into the Click 200
Wiring through a 5-screw Terminal
If you choose not to use a Click 200, or if you have one but prefer not to wire through it,
you can also connect power through a 5-screw terminal block connected to the end of the
T-bus.
To provide power to a T-bus through a 5-screw terminal block, follow these steps:
1 Attach a male 5-screw terminal block to the le end of the T-bus by aligning it with the
rst connector and pushing the modules together.
2 Connect the black (ground) and red (+24 VDC) wires from the Click 201/202/204
into the top two screw terminals in the 5-screw terminal block (see Figure 2.2 for the
5-screw terminal block pinout).
Figure 2.2 – 5-screw Terminal Block Pinout
Note
To disconnect a 5-screw terminal block from a T-bus connector, use a small, thin item,
such as a small screwdriver, to gently pry the two modules apart.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229

Wavetronix Click 100 User guide

Category
Network switches
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI