Reznor ZQYRA is a versatile ventilation unit designed to provide efficient and reliable air handling solutions for various applications. It offers precise control over temperature, humidity, and airflow, making it suitable for diverse environments such as offices, warehouses, and educational facilities. With its rugged construction and user-friendly interface, the Reznor ZQYRA ensures optimal indoor air quality and comfort.

Reznor ZQYRA is a versatile ventilation unit designed to provide efficient and reliable air handling solutions for various applications. It offers precise control over temperature, humidity, and airflow, making it suitable for diverse environments such as offices, warehouses, and educational facilities. With its rugged construction and user-friendly interface, the Reznor ZQYRA ensures optimal indoor air quality and comfort.

Revision: P-ZQYRA (10-20) 262961-A
REPLACEMENT PARTS FOR Z SERIES VENTILATION UNIT
Supersedes: P-ZQYRA (08-19) PN262961R13
IMPORTANT
1. Always include complete model and serial number so that any specification change can be considered for parts
replacement. It can save time and expense.
2. In keeping with our policy of continuous product improvement, we reserve the right to alter any information shown
here. Specifications are subject to change without notice.
3. We reserve the right to substitute functional replacements.
4. Order by Part Number (PN), not by option designation.
MODEL ZQYRA
TABLE OF CONTENTS
IMPORTANT SAFETY INFORMATION ................................................................................................................... 2
REFERENCES ......................................................................................................................................................... 2
RATING PLATE ........................................................................................................................................................ 2
SERIAL NUMBERS ................................................................................................................................................. 3
ELECTRICAL COMPONENTS ................................................................................................................................ 4
OPTIONAL OCCUPANCY CONTROL COMPONENTS .......................................................................................... 7
DISCONNECT SWITCHES ...................................................................................................................................... 8
OPTIONAL ELECTRIC PRE-HEAT COMPONENTS .............................................................................................. 9
INLET DAMPER ASSEMBLY COMPONENTS ....................................................................................................... 9
ENERGY RECOVERY WHEEL COMPONENTS ................................................................................................... 10
FAN ASSEMBLY COMPONENTS ......................................................................................................................... 11
REFRIGERANT CIRCUIT COMPONENTS ........................................................................................................... 12
EXTERNAL CABINET COMPONENTS, REPLACEMENT FILTERS, AND AIR HOODS ..................................... 14
ROOF CURB ASSEMBLY ..................................................................................................................................... 16
2
P-ZQYRA (10-20) 262961-A
IMPORTANT SAFETY INFORMATION
⚠ DANGER ⚠
This unit contains R-410A high pressure refrigerant. Hazards exist that could result in personal injury
or death. Installation, maintenance, and service should be performed only by an HVAC technician
qualified in R-410A refrigerant and using proper tools and equipment. Due to much higher pressure
of R-410A refrigerant, DO NOT USE service equipment or tools designed for R22 refrigerant.
⚠ WARNING ⚠
IMPORTANT: Do not release refrigerant to the atmosphere! If required service procedures include
the adding or removing of refrigerant, the service technician must comply with all federal, state,
and local laws. Service procedures should be performed only by a qualified HVAC technician.
REFERENCES
MERCER, PA. USA 16137
MADE IN MEXICO
FOR INDUSTRIAL/COMMERCIAL USE ONLY
SUITABLE FOR INDOOR OR OUTDOOR USE
MODEL [ A ][ B ]
SERIAL NO. [ ]
[ C ] VOLTS [ C ] PH [ C ] HZ
MINIMUM CIRCUIT AMPACITY (MCA) [ V } AMPS
MAXIMUM FUSE SIZE/*CIRCUIT BREAKER (MOP) [ W } AMPS
MINIMUM CIRCUIT AMPACITY (MCA) [ D } AMPS
MAXIMUM FUSE SIZE/*CIRCUIT BREAKER (MOP) [ E } AMPS
SHORT-CIRCUIT CURRENT: 5,000 RMS SYMMETRICAL, [ C ] V MAXIMUM
QTY FLA WATTS
SUPPLY AIR BLOWER MOTOR1[ F ][ G ]
QTY FLA [ U ]
EXHAUST AIR BLOWER MOTOR1 [ H ][ J ]
QTY FLA HP
ENTHALPY WHEEL MOTOR1[ K ][ L ]
QTY RLA (EA) LRA (EA)
COMPRESSOR1[ M ][ N ]
REFRIGERANT - R410A CHARGE - [ P ] LBS
TEST PRESSURES: HIGH 600 PSIG; LOW 45 PSIG
EQUIPPED FOR OPERATION AT SUPPLY AIR FLOW RANGE OF [ Q ] SCFM
AGAINST A STATIC PRESSURE RANGE OF [ R ] INCHES WATER COLUMN
WIRE DIAGRAM [ S ]
ELECTRIC HEAT [ T ] kW (if equipped)
*HACR TYPE REQUIRED PER NEC
RATING PLATE
SAMPLE RATING PLATE AND KEY
Table 1. Related Technical Manuals Available from Factory Distributor
Type Form
PN*
Installation/operation/maintenence I-ZYQRA 260414
Remote mounted display (option RB5) installation I-RB5 Display 260737
Roof curb (option CJ) installation D303068
Retrofit kit installation for units manufactured before OCT 2012 CP-Z Retrofit Kit 269983
*Also available at www.reznorhvac.com.
3
P-ZQYRA (10-20) 262961-A
A = Model
B = Manufacturing Date (Month/Year)
C = Volts/Phase/Hertz
D = Minimum Circuit Ampacity (MCA)
E = Maximum Fuse Amps
F = Supply Air Blower Motor Full Load Amps
G = Supply Air Blower Motor Watts
H = Exhaust Air Blower Motor Full Load Amps
J = Exhaust Air Blower Motor Watts or HP (See U)
K = Enthalpy Wheel Motor Full Load Amps
L = Enthalpy Wheel Motor HP
M = Compressor Rated Load Amps
N = Compressor Locked Rotor Amps
P = R410-A Refrigerant Charge (Pounds)
Q = Airflow (SCFM)
R = Static Pressure (IN WC)
S = Wiring Diagram PN
T = Electric Heat kW
U = Exhaust Air Blower Motor Watts or HP (See J),
Option A23 = HP or A24 = Watts
SERIAL NUMBERS
Serial number format changed in June of 2015. Use the following information to decode system serial numbers:
DECODING A SYSTEM SERIAL NUMBER FOR ALL MODELS BEFORE JUNE 2015
Serial No. Sample: BLL 00000 X
Elements of No.: 1 | 2 | 3
Key:
1 = Date code (refer to Table 2)
2 = Consecutive number
3 = Plant of manufacture (X = Monterrey)
DECODING A SYSTEM SERIAL NUMBER FOR ALL MODELS AFTER MAY 2015
Serial No. Sample: BOF 3060 00000
Elements Key No.: 1 | 2 | 3
Key:
1 = Date code (refer to Table 2)
2 = Plant of manufacture (3060 = Mercer; 3062 = Monterrey)
3 = Consecutive number
Table 2. Serial Number Date Codes (Month and Year)
Year
Month
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
2013
BMA BMB BMC BMD BME BMF BMG BMH BMI BMJ BMK BML
2014
BNA BNB BNC BND BNE BNF BNG BNH BNI BNJ BNK BNL
2015
BOA BOB BOC BOD BOE BOF BOG BOH BOI BOJ BOK BOL
2016
BPA BPB BPC BPD BPE BPF BPG BPH BPI BPJ BPK BPL
2017
BQA BQB BQC BQD BQE BQF BQG BQH BQI BQJ BQK BQL
2018
BRA BRB BRC BRD BRE BRF BRG BRH BRI BRJ BRK BRL
2019
BSA BSB BSC BSD BSE BSF BSG BSH BSI BSJ BSK BSL
2020
BTA BTB BTC BTD BTE BTF BTG BTH BTI BTJ BTK BTL
2021
BUA BUB BUC BUD BUE BUF BUG BUH BUI BUJ BUK BUL
2022
BVA BVB BVC BVD BVE BVF BVG BVH BVI BVJ BVK BVL
2023
BWA BWB BWC BWD BWE BWF BWG BWH BWI BWJ BWK BWL
2024
BXA BXB BXC BXD BXE BXF BXG BXH BXI BXJ BXK BXL
2025
BYA BYB BYC BYD BYE BYF BYG BYH BYI BYJ BYK BYL
4
P-ZQYRA (10-20) 262961-A
ELECTRICAL COMPONENTS
NOTE:
Controls are located on either side or on the back wall of the control compartment.
The optional communication cards—BACnet® card (option BHB8, item 1A) or LONworks® card
(option BHB7, item 1B)—are located on the unit controller (item 1).
Figure 1. Electrical Compartment Components (Refer to Table 3)
17 (Exhaust
Fan)
17 (Supply Fan)
9 (Wheel)
10 (Fans)
15
11
9 (Heat Pump)
19
5
7 (Optional
Dam
p
er Motor
)
7
1
4
4A
9 (Supplemental
Heating Element)
14
6
13
8, 8A, and 8B
Electrical Compartment: Controls on Top with Compressor Below
9 (Electric Pre-Heat Option)
16
25
3
12
5
P-ZQYRA (10-20) 262961-A
Figure 2. Individual Electrical Components (Refer to Table 3)
Items 4 and
24A: Unit
and Remote
Displays
Item 1: Unit
Controller
Item 7:
Transformer
Item 5: Compressor
Controller
Item 8:
Transformer
Item 1A
Item 1BB
Item 1B
Items 1A, 1B, and 1BB: Communication Cards/Brackets
Items 9
and 10:
Contactor
Item 11:
Distribution
Block
Items 12
and 13:
Overload
Relay
Items 14
and 14A:
Damper
Motor Relay
and Socket
Item 15: Relay
Module
Item 16: Dirty
Filter Pressure
Switch
Item 17: Air
Proving Switch
Item 20:
Electric
Heating
Element
Item 21:Temperature
Sensor
Item 23: Discharge
Air Temperature
Sensor
Item 22: Humidity and
Temperature Sensor
1.56"
(40 mm)
(2) Cable Splitter and Signal Booster Modules, PN 260735
2.75" (70 mm)
3.13" (80 mm)
Front and Side Views with Dimensions
0.219"
(6 mm)
1.125"
(29 mm)
0.91"
(23 mm)
(2) 6-Pin Connection
Cables, PN 260175
6
0
A
B
S
Items 24B and 24C: Connection Cable and Booster Module
6
P-ZQYRA (10-20) 262961-A
Table 3. Electrical Components
Item
No.
Component Description
Unit Size
Reference
8 12
PN (Quantity)*
1 Unit controller Digital, with programmed software (Carel)
263663 (units manufactured before APR 2016)
Figure 1,
Figure 2
1010784 (units manufactured after MAR 2016)
1A BacNet
®
communication card Programmed (option BHB8) 262964
Figure 2
1B LON
®
communication card Programmed (option BHB7) 262963
1BB Bracket LON
®
communication card 262743
2 Cable Connection, for unit controller 260175
3 Terminal block Kit, for unit controller
260176 (units manufactured before APR 2016)
Figure 1
260177 (units manufactured after MAR 2016)
4 Display Unit 267178
Figure 2
4A Bracket Unit display 269895
Figure 1
5 Compressor controller Digital 266067
Figure 1,
Figure 2
6 Resistor Digital control, 560K ohms 268534
Figure 1
7 Transformer 75VA, 120/208-240/480 to 24 208989 (2 or 3)
Figure 1,
Figure 2
8 Transformer 200VA, 460V/3PH/60Hz 210862
8A Fuse clip For 200VA transformer 257033
Figure 1
8B Time delay fuse For 200VA transformer, 1/10–30A 259433
9
Contactor
25A, 24VAC coil 216386 (3 or 4)
Figure 1,
Figure 2
10 40A, 24VAC coil 216387
11 Distribution block 115A, A, B, or C 207641 (3)
12
Overload relay 4A, supply fan 260181
Monitoring relay 208–230V, supply fan
1012191**
12A
Terminal bracket Overload relay 260183 (2)
Support Monitoring relay
1012192**
13
Overload relay 12A, exhaust fan 260182
Figure 1,
Figure 2
Monitoring relay 208–230V, supply fan
1012191**
13A
Terminal bracket Overload relay 260183 (2)
Support Monitoring relay
1012192**
14 Damper motor relay 24VAC, DPDT 211411
Figure 1,
Figure 2
14A Socket Plug-in 211415
15 Relay module
Multi-voltage, for time schedule clock
(option CN7A)
260189
16 Pressure switch Dirty filter (option BE18) 105507
17 Air proving switch 0.35 IN WC, purple label, supply or exhaust fan 197031 (2)
18 Control, SCR power
Viconics #R820-443 (option AK7) 220688
Viconics #R820-343 (option AK5 and AK6) 234057
19 Grounding lug 179196
Figure 1
20
Electric heating element
(located in supply airstream)
10kW@208V (option AK5)
272504***
Figure 2
10kW@230V (option AK6)
221687***
10kW@460V (option AK7)
221688***
20A Limit control 14040°F, for electric heating element
254754***
20B Bracket For electric heating element
269982***
21
Sensor
Temperature, on condenser coil header
269894***
Figure 2
22 Humidity and temperature 260170 (2)
23 Discharge air temperature (field-installed) 222753 (2)
24 Remote display kit Option RB5 (field-installed) 260436
24A Display Remote 260178
24B Cable Connection, 6-pin 260175 (2)
24C Module Cable splitter and signal booster 260735 (2)
25 Terminal block 144972
Figure 1
*Quantity is one (1) unless otherwise indicated.
**For units manufactured after FEB 2017 that have either 208V or 230V supply.
***For units manufactured after OCT 2012. If these parts are needed for defrost mode on previously-manufactured units, contact Distributor
or Factory Service Department about retrofit procedure.
ELECTRICAL COMPONENTS—CONTINUED
7
P-ZQYRA (10-20) 262961-A
OPTIONAL OCCUPANCY CONTROL COMPONENTS
NOTE: There are five wall-mounted occupancy control options that require field-installation and
wiring.
Figure 3. Occupancy Control Options (Refer to Table 4)
START
STOP
START
STOP
2 Key Positions
KEY LOCK
POWER SWITCH
CN5
2-Position (start/stop)
Key Switch, P/N 260227
Cover, P/N 260229
Label, P/N 260228
Reference
Components and wiring information for
Option CN5.
83
= field wiring
= field connection terminal block in the
electrical compartment of the unit
Multi-Voltage Relay Module (PN 260189)
used with option CN7A is mounted in
electrical compartment at factory
Time ClockWall Switch,
Leviton Model VPT24-1P
(PN 260188)
BK
BL
W
O
R
BK
W
Y/R
R
G/Y
(HOT) BK
(NEUT) W
}
115/1/60
LINE
PAM-1
TIMER
SWITCH
Y
22
23
BL
8
Multi-voltage
relay
(see below)
3
= field wiring
= field connection terminal block
CO
2
Sensor,
P/N 234820
Keyed, 3-Position Wall
Switch, P/N 260230
Cover, P/N 260229
Label, P/N 260231
3 Key Positions
HAND
OFF
AUTO
HAND
AUTO
OFF
Reference
11
SW2
AUTO & HAND
AUTO
SW1
8
SHIELD
2
GROUND
4
SIGNAL
CO2 SENSOR
SHIELD
(OPT. CN7B)
2
POWER
1
GROUND
SWITCH
KEYED
9
3
= field wiring
= field connection terminal block
in the electrical compartment of
the ventilation unit
Option CN7B:
HAND/OFF/AUTO
CO
2
Sensor Switch
Option CN7C: HAND/
OFF/AUTO Indoor Air
Quality (VOC and CO)
Sensor/Switch
COM
RELAY
OUTPUT
COMM
INPUT
POWER
24V IN
N.O.
OCCUPANCY SENSOR
PW-100-24
OPTCN7D
8
11
10
3
= field wiring
Option CN7D: ON/OFF
Occupancy Motion
Sensor/Switch
VOC and CO
Sensor, P/N 260192
Keyed, 3-Position Wall
Switch, P/N 260230
Cover, P/N 260229
Label, P/N 260231
3 Key Positions
HAND
OFF
AUTO
HAND
AUTO
OFF
Reference
11
SW2 AUTO & HAND
SW1 AUTO
8
SHIELD
1
GROUND
3
SIGNAL
IAQ SENSOR
SHIELD
(OPT. CN7C)
1
POWER
2
GROUND
SWITCH
KEYED
3
9
3
= field wiring
Option CN5: START/STOP
Wall Switch
Option CN7A: ON/OFF
Time Clock Wall Timer
Switch
8
P-ZQYRA (10-20) 262961-A
DISCONNECT SWITCHES
NOTE:
The 60-amp disconnect switch (PN 205906) was originally factory-installed as option BA6 (see
Figure 4).
The CP-option disconnect switches (see Figure 5) are listed in Table 5.
Figure 4. Disconnect Switch (PN 205906)
Figure 5. CP-Option Disconnect Switch
(Refer to Table 5)
Table 4. Occupancy Control Options
Component Manual Control Type Option PN
START/STOP wall switch Two-position key switch CN5 260431
ON/OFF time clock wall timer/switch Override switch CN7A 260432
HAND/OFF/AUTO CO
2
sensor/switch
Three-position key switch
CN7B 260433
HAND/OFF/AUTO indoor air quality (VOC and CO) sensor/switch CN7C 260434
ON/OFF occupancy motion sensor/switch Override switch CN7D 260435
OPTIONAL OCCUPANCY CONTROL COMPONENTS—CONTINUED
Table 5. CP-Option Disconnect Switches
Amps Volts Fusible/Non-Fusible Option PN Installation Location
30
240
Non-fusible CP5 40269
USFusible CP6 87147
600
Non-fusible
CP7 50367
CP59 208054 Canada
Fusible
CP8 50368 US
CP42 208045 Canada
60
240
Non-fusible CP30 161469
USFusible CP17 89932
600
Non-fusible
CP38 155012
CP61 208056 Canada
Fusible
CP20 90974 US
CP44 208048 Canada
9
P-ZQYRA (10-20) 262961-A
OPTIONAL ELECTRIC PRE-HEAT COMPONENTS
NOTE: Pre-heat options (PH1A (5kW) or PH2A (10kW)) include an electric pre-heat element in
addition to the supplemental heating element.
Figure 6. Optional Electric Pre-Heat Components (Refer to Table 6)
Table 6. Optional Electric Pre-Heat Components
Pre-Heat
Option
Component
Volts/Phase/Hertz
(Voltage Option)
Unit Size
8 12
PN (Quantity)
PH1A Heating element, 5kW
208/3/60 (AK5) 260184 (1)
230/3/60 (AK6) 260184 (1)
460/3/60 (AK7) 260185 (1)
PH2A Heating element, 10kW
208/3/60 (AK5) 260184 (2)
230/3/60 (AK6) 260184 (2)
460/3/60 (AK7) 260185 (2)
PH1A and PH2A Support bracket 259628 (1) 259627 (1)
INLET DAMPER ASSEMBLY COMPONENTS
NOTE: The electrically-actuated inlet damper assembly (option AR2Y) may be used on both unit
sizes 8 and 12.
Figure 7. Inlet Damper Actuator
5kW10kW
HEATING
ELEMENTS
SUPPORT
BRACKETS
10
P-ZQYRA (10-20) 262961-A
Table 7. Inlet Damper Assembly Components
Component Description
Unit Size
8 12
PN (Quantity)*
Damper assembly Inlet 261879 261880
Damper
19-3/8 × 23-7/8 261877
19-3/8 × 29-7/8 261878
Damper frame
Top/bottom (2) 261881
Side (2) 261883 (2) 261884
Exhaust damper
20 × 24 (option A23) 260179
14-1/2 × 11-1/2 (option A23) 209219
20 × 24 (option A24) 260179
Actuator (see Figure 7) Inlet damper 209351
Shaft extension**
3-1/4-inch 254743
6-inch 254744
*Quantity is one (1) unless otherwise indicated.
**Required when replacing actuator on unit manufactured before JUL 2012 (serial No. date code = BLG).
ENERGY RECOVERY WHEEL COMPONENTS
Table 8. Energy Recovery Wheel Components
Component Description
Unit Size
8 12
PN (Quantity)*
Wheel support Top/bottom 259590 (2) 259567 (2)
Energy recovery wheel cassette
(includes following parts)
208V/3PH/60Hz (option AK5)
260151
260152
230V/3PH/60Hz (option AK6) 260152
460V/3PH/60Hz (option AK7) 260153
Motor, wheel
208V/3PH/60Hz (option AK5)
263294
263295
230V/3PH/60Hz (option AK6) 263295
460V/3PH/60Hz (option AK7) 263296
Belt
Wheel
262488 262489
Segment 263297 263299
Section 263298 (4) 263300 (6)
*Quantity is one (1) unless otherwise indicated.
Figure 8. Energy Recovery Wheel Components (Refer to Table 8)
INLET DAMPER ASSEMBLY COMPONENTS—CONTINUED
Top and bottom
wheel supports
Wheel access panel
Blockoff panel
Wheel cassette
11
P-ZQYRA (10-20) 262961-A
FAN ASSEMBLY COMPONENTS
NOTE: The supply (see Figure 9) and exhaust (see Figure 10) fans are driven by Electronically-
Commutated Motors (ECMs).
Figure 9. Supply Fan Assembly (Refer to Table 9)
1
4
3
2
0.393 inches
(10 mm)
Side View
4
Supply Fan Location
Table 9. Supply Fan Assembly Components
Item
No.
Component Description
Fan
Option
V/PH/Hz
Unit Size
8 12
PN (Quantity)*
1
Supply fan
(with ECM motor)
R3G310-AX64-11
A24 and A23
208–230/3/60
259953
R3G310-AX64-11 259953
R3G310-AX52-90
460/3/60
259351
R3G310-AX52-90 259351
2 Inlet ring 31575-2-4013
All
259352
3 Support Fan 259959
4 Bracket Fan support 259960 (2)
*Quantity is one (1) unless otherwise indicated.
Figure 10. Exhaust Fan Assembly (Refer to Table 10)
1
2
3
4
Side View
0.354 inches
(9 mm)
0.16 inches
(4 mm)
4
5
6
16
7
15
14
Exhaust Blower
and Motor Assembly
(Option A23): does
not apply to units
manufactured
after 2012
8
9
Exhaust Fan Location
12
P-ZQYRA (10-20) 262961-A
Table 10. Exhaust Fan Assembly Components
Item
No.
Component Description
Fan
Option
V/PH/Hz
Unit Size
8 12
PN (Quantity)*
1
Exhaust fan
(with ECM motor)
40075-2-4013
A24
208–230/3/60
259952
R3G400-AQ29-11 259954
R3G355-AY40-01
460/3/60
259349
R3G400-AQ23-01 259353
2 Inlet ring
35675-2-4013
All
259350
40075-2-4013 259354
3 Support Fan 260005 259964
4 Bracket Fan support 260004 (2) 259965 (2)
5 Blower motor 3-HP (A.O. Smith H845)
A23 and A24
159185
6 Housing Blower 259613
7 Mounting plate Motor 259833
8
Support, motor plate
Right 12577
9 Left 12576
10 Nut (not shown) Hex, 5/16-18 1035 (2)
11 Washer (not shown) Flat, 5/16 SAE 1087 (10)
12 Nut (not shown) Keps, 5/16 6554 (10)
13 Rod (not shown) Threaded, 5/16-18 12489 (2)
14 Motor sheave
Low static (option AME4) 106748
High static (option AME5) 106748
15 Blower sheave
Low static (option AME4) 157584
High static (option AME5) 260417
16
Belt, linked**
42-inch (option AME4)
201809
38-1/2-inch (option AME5)
*Quantity is one (1) unless otherwise indicated.
**There are 17 links per 12 inches (305 mm) of belt.
FAN ASSEMBLY COMPONENTS—CONTINUED
REFRIGERANT CIRCUIT COMPONENTS
NOTE: Compressor compartment components are shown in Figure 11 (the compressor control-
ler is shown in Figure 1). Coil compartment components are shown in Figure 12. All refrigerant
circuit components are listed in Table 11.
Figure 11. Compressor Compartment Components (Refer to Table 11)
8
6
5
1
9
10
7
16
Compressor Compartment: Compressor Below
with Controls on Top
13
P-ZQYRA (10-20) 262961-A
Figure 12. Coil Compartment Components (Refer to Table 11)
Figure 13. Individual Refrigerant Circuit Components (Refer to Table 11)
Check Valve
Flow Direction
Expansion Valve
Flow Direction
13
TXV Bulb Location
Check Valve
Flow Direction
Expansion Valve
Flow Direction
13
TXV Bulb Location
Compressor
12
11
Control Side View
Side Opposite Controls View
(partial view)
Condensate Drain
15
15
Item 2:
Compressor
Mounting Kit
Item 3: Crankcase
Heater
Item 4: Molded
Plug
Item 6: High
Pressure Switch
Item 7: Low
Pressure
Switch
Item 8: Four-Way
Reversing Valve
Item 9:
Thermistor
Item 10: Solenoid
Valve Kit
Item 13:
Thermostatic
Expansion Valve
Item 14:
Filter
Drier
Item 15:
Check
Valve
Compressor Compartment Components Coil Compartment Components
14
P-ZQYRA (10-20) 262961-A
EXTERNAL CABINET COMPONENTS, REPLACEMENT FILTERS, AND AIR HOODS
NOTE: External cabinet components (see Figure 12) include replacement filters (refer to Table
13) and air hoods (refer to Table 14). The inlet air hood package is the same inlet air hood that is
shipped with the original unit.
Figure 14. External Cabinet Components
Table 11. Refrigerant Circuit Components
Item
No.
Component Description
Unit Size
Reference
8 12
PN (Quantity)*
1 Compressor
208V/3PH/60Hz (option AK5) 259288 260741
Figure 11
230V/3PH/60Hz (option AK6) 259288 260741
460V/3PH/60Hz (option AK7) 259355 260742
2 Mounting kit Compressor 205825
Figure 13
3 Crankcase heater
208V/3PH/60Hz (option AK5) 216394
230V/3PH/60Hz (option AK6) 216394
460V/3PH/60Hz (option AK7) 216396
4 Molded plug 5-inch, for compressor 205630
5 Accumulator 259295
Figure 11,
Figure 13
6
Pressure switch
High, located in discharge line 216379
7 Low, located in suction line 216380
8 Four-way valve Reversing 259297
9 Thermistor 266069
10 Solenoid valve Kit 266071
11
Coil
Evaporator 259302 259301
Figure 12
12 Condenser 259303 259300
13 Expansion valve Thermostatic 1028249 (2)
Figure 12,
Figure 13
14 Filter drier 259293
Figure 13
15 Check valve 259292 (2)
Figure 12,
Figure 13
16 Compensator 1005110 1005111
Figure 11
*Quantity is one (1) unless otherwise indicated.
REFRIGERANT CIRCUIT COMPONENTS—CONTINUED
Inlet
Air
Hoods with Filters
Vertical Supply Air Opening (In the bottom)
Vertical Return Air Opening
(in the bottom)
10
24
Exhaust
Hood
Disconnect Switch
Electric Heat (Optional)
Exhaust Fan Access
Horizontal
Supply Air
Horizontal
Return Air
Opening
(Control Side)
21
23
Enthalpy Wheel Access
11
15
16
17
18
1
2
2
3
7
5
4
12
19
8
13
26
6
25
20
P-ZQYRA (10-20) 262961-A
15
Table 12. External Cabinet Components
Item
No.
Component Description
Unit Size
8 12
PN (Quantity)*
1
Corner post
Control, without disconnect 261134 261169
Control, with disconnect (option BA6) 261135 261170
2 Supply and exhaust corners 261136 (2) 261168 (2)
3 Inlet air corner 261745 261785
4
Frame support
Top, side 261830 (2)
5 Top, end 261871 (2)
6
Panel
Drain cover 261792
7
Exhaust side, with fan option A23 261200
Exhaust side, with fan option A24 261833 261834
8 Inlet side 261793 261794
9 Supply/return air side 261840 261841
10
Cover
Post, inlet side 261795 261796
11 Post, control side 261797 261798
12 Top 261845
13 Return air opening (fits either vertical or horizontal opening) 259938
14
Supply air opening, horizontal**
259939
Supply air opening, vertical** 259941***
15
Exhaust opening, hardware cloth, with fan option A23 260221
Exhaust opening, hardware cloth, with fan option A24 260180
16
Frame
Exhaust opening, with fan option A23 260223
17 Exhaust opening bottom/top, with fan option A24 260208 (2)
18 Exhaust opening side 260222 (2)
19
Door
Wheel access 261801 261802
20 Control access 261805 261806
21 Return air filter access 261809 261810
22 Exhaust fan access 261818 261819
23 Inlet filter access 261822 261823
24 Supply fan access 261828 261829
25 Grommet 3/4-inch, for drain cover panel 15021
26 Lug Lifting 259828 (4)
27
Pan, drain**
Kit
1020522 (units manufactured before AUG 2017
(replaces PN 259298))
1013001 (units manufactured after JUL 2017)
*Quantity is one (1) unless otherwise indicated.
**Not shown.
***Also included in inlet air hood package (refer to Table 14).
Table 13. Replacement Filters
Type
Unit Size
Size Location PN Qty
Pleated
8 16 × 20 × 2
Inlet air
104110
2
Return air 1
12
16 × 20 × 2 Inlet air 104110 2
16 × 25 × 2 Return air 104112 1
Table 14. Air Hoods
Type Component Description
Unit Size
Size 8 Size 12
PN (Quantity)*
Inlet air
Package Inlet air hood 262339 262340
Rubber gasket
3/32 × 1-1/8**
Bag Parts 260354
Hood
Upper inlet 262662
Lower inlet 262663 262663 (2)
Bracket
Cross, front 262668 (2) 262668 (3)
Cross, rear 262669 (2) 262669 (3)
Filter, side 262671 (4) 262671 (6)
Panel Filter access 262670 (2) 262670 (3)
Filter Aluminum, 1 × 14-1/2 × 22-1/2 262673 (2) 262673 (3)
Filler plate Front 262672
Table 14. Air Hoods
Type Component Description
Unit Size
Size 8 Size 12
PN (Quantity)*
Exhaust air
Panel
Left side 260210
Right side 260211
Cover Hood top 261138 261855
*Quantity is one (1) unless otherwise indicated.
**Length of rubber gasket provided is 103 inches for unit size 8 or 115 inches for unit size 12.
Specifications and illustrations subject to change without notice or incurring obligations.
©2020 Nortek Global HVAC LLC, O’Fallon, MO.
All rights reserved.
P-ZQYRA (10-20) 262961-A
A
G
E
N
C
Y
P
R
O
C
E
S
S
S
T
A
R
T
-
U
P
P
R
O
D
U
C
T
C
U
S
T
O
M
E
R
W
A
R
R
A
N
T
Y
C
O
N
V
E
R
G
E
N
T
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
CQS
Q
M
CQS
Table 15. Roof Curb Assembly Components
Item Component Description PN
Package Roof curb (same as option CJ3) 260418
1
Curb
Front side 260215
2 Right end 260216
3 Left end 260217
4 Rear side 260218
5
Center support
259636
6 Discharge air 259640
7
Cross support
Return air
259637
8 259639
9 Discharge air 259638
10
Duct angle support
Right end, discharge air 259641
11 Front side, discharge air 259642
12 Right end, return air 259643
ROOF CURB ASSEMBLY
EXTERNAL CABINET COMPONENTS, REPLACEMENT FILTERS,
AND AIR HOODS—CONTINUED
—Continued
Figure 15. Roof Curb Assembly
Bottom View
Top View
Return Air
Duct Flange
Supply Air
Duct Flange
3
4
5
1
6
11
10
9
2
12
7
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Reznor ZQYRA User manual

Type
User manual

Reznor ZQYRA is a versatile ventilation unit designed to provide efficient and reliable air handling solutions for various applications. It offers precise control over temperature, humidity, and airflow, making it suitable for diverse environments such as offices, warehouses, and educational facilities. With its rugged construction and user-friendly interface, the Reznor ZQYRA ensures optimal indoor air quality and comfort.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI