CALLING MODULE PROGRAMMING PROCEDURE
START
2
−−−−
sec.2a
2GO! - Technical manual
CALLING MODULE PROGRAMMING
PROCEDURE
The calling module with repertory may be programmed as follows:
Locally, via the keypad, without opening the module frame.
Via remote Palm OS device provided with IrDA interface and
software downloadable from the site www.urmetdomus.com.
Via GSM modem Ref. 1082/52 and PC software downloadable
from the site www.urmetdomus.com.
PARAMETERS
The following parameters will need to be programmed:
1. OPERATING LANGUAGE
Up to 10 different operating languages can be selected.
2. NUMBER OF LINES
The number of lines managed by the device can be selected. The
device can manage one 2GO! line (up to 31 users) or two 2GO!
lines (up to 62 users).
3. SURVEILLANCE CAMERAS
This parameter enables external camera cycle function.
Surveillance camera can be connected to the door unit (terminals
V3, V5) using a relay box Ref. 1038/69 controlled by terminals T,
GND.
4. FIRST CODE
The admissible values for the fi rst code are comprised in the range
from 1 to 62. The fi rst code indicates the beginning of the range of
users who can operate the door lock also if no communication is
established (if free door opener function is enabled).
5. LAST CODE
The admissible values for the last code are comprised in the
range from 1 to 62. The last code indicates the end of the range of
users who can operate the door lock also if no communication is
established (if free door opener function is enabled).
6. SPECIAL CODE
The admissible values for the special code are comprised in the
range from 1000 to 9999. The special code is used to enable
the staircase light function, if a special decoder is present in the
system.
7. PASSWORD
The admissible values for the password are comprised in the
range from 1000 to 9999. The password is used to program the
calling module.
8. MODULE ID
This value indicates the module code. Possible values are 1, 2
and 3.
9. DOOR PHONE/VIDEO DOOR PHONE CODE
Admissible values are in the range from 1 to 99. The codes from 1
to 49 indicate that the device is provided with camera. The codes
from 50 to 99 indicate that the device is only a door phone. This
also indicates the remote device programming code.
10. LCD CONTRAST
The display contrast level of the display is set by default to an
optimal level. The setting can be changed if needed.
11. MODULE TYPE
The calling module may be a main device or a secondary
device. See the 2GO! system manual for main/secondary device
management.
12. DOOR OPENER MODE
Two door opener modes may be selected:
Privacy.
Free.
13. NAMES
Up to 186 names can be entered in the calling module. Refer to
the programming steps shown below for entering names.
•
•
•
•
•
14. DOOR OPENER CODES
Up to 100 door opener codes, unrelated to names, for general
use, can be stored in the calling module.
PROGRAMMING BY KEYPAD
Press / to scroll the various programming menus. Press to
confi rm selections. Press X to quit.
Press 0 twice to access device programming mode. The following
message will appear:
Enter the password and press to confi rm. The following message
will appear if the password is not correct:
Enter a correct password to access the multilevel menu shown below
and described next to the various screenshots.
The fi rst menu level is:
LANGUAGE MENU
Select the language menu. The following will appear:
↓
•••••••••••••••••••••••••••••••••••••••••••••
Press / to select the required language. Press to confi rm
selection. Press X to return to the fi rst level menu.
CALLING MODULE PROGRAMMING PROCEDURE
PARAMETERS
PROGRAMMING BY KEYPAD
CALLING MODULE PROGRAMMING PROCEDURE