CALLING MODULES
Ref. 1082/14K-STEEL CALLING MODULE WITH REPERTORY
4
−−−−
sec.3c
2GO! - Technical manual
K-STEEL CALLING MODULE WITH REPERTORY Ref. 1082/14
PROGRAMMING
INSTALLATION
HALL BUTTON SIGNAL MANAGEMENT
The door unit manages the hall button contact (PA contact). Press the
button (closed contact): the calling module will operate the electrical
lock.
AUTO POWER-ON, SURVEILLANCE CAMERA
MANAGEMENT
Auto power-on is operated on main door unit ID 1. The user will see
the video door unit camera frame when the video door phone auto
power-on button is pressed once. The surveillance camera frames will
be shown in cycle when the button is pressed again. Communication
is established with the video door unit and the respective camera
frame is shown when the user picks up the handset.
The cycle will last for up to the off-hook time (60 seconds) after which
the system returns to stand-by.
ELECTRICAL LOCK
The door unit operates the electrical lock by means of a capacitance
discharge.
The electrical lock is controlled by a pulse (1 second) which can be
managed as follows:
Privacy door opener:
the electrical lock can only be operated by the apartment station
which is communicating with the calling station.
Free door opener:
the electrical lock can be operated also if the apartment station has
not established a communication with the calling station.
The apartment stations which can operate the electrical lock, also
if no communication is established, are those included in the range
from the fi rst code to the last code (see programming).
PROGRAMMING
The calling module with repertory may be programmed as follows:
Locally, via the keypad, without opening the module frame.
Via remote Palm OS device provided with IrDA interface and
appropriate software downloadable from www.urmetdomus.com.
Via Ref. 1082/52 GSM modem and PC software downloadable
from www.urmetdomus.com.
For programming mode refer to the section 2A “Calling module”.
DEFAULT SETTINGS
The default confi guration settings are:
LANGUAGE Italiano
NUMBER OF LINES 2
SURVEILLANCE CAMERAS Off
SPECIAL CODE 1111
PASSWORD 9999
MODULE TYPE Main
DOOR OPENER Privacy
FIRST CODE 1
LAST CODE 62
MODULE ID 1
DOOR PHONE/
VIDEO DOOR PHONE CODE 11 (Video door phone position)
Switch on the device pressing X, 1, 4 and 7 to restore the default
settings.
•
•
•
§
INSTALLATION
The calling module with repertory Ref. 1082/14 can be used alone or
in a combination with a camera unit.
Examples of modular constructions using 2 or 3 module holder frames
with respective fl ush-mounting boxes are shown below.
The door unit module should be installed at a height of approximately
1.55 ÷ 1.60 metres.
h = 1,55 ÷ 1,60 m
X
7
4
1
0
8
5
2
9
6
3
Important
The module should not be illuminated from behind to make the calling
module display easier to read. Never direct the module towards
strong sources of light (e.g. the sun, lampposts, light bulbs, fl ashes
or glare).
FLUSH-MOUNTED VERSION
Purchase fl ush-mounting boxes, frames and module holders
separately for wall mounting. The product codes (according to number
of modules) are:
NUMBER OF
MODULES
FLUSH MOUNTING
BOXES AND MODULE
HOLDERS
FRAME
2 1155/52 1155/85 or 1155/92
3 1155/53 1155/86 or 1155/93
Refer to “Technical product manual - Door phone and video door
phone systems”, “K-Steel panels” section for dimensions and
additional details on these products.
Refer the protections from the hole to be used to pass the wires
only from the fl ush-mounting box.
The holes in the upper part must only be used for introducing the