  • Hello! I am an AI chatbot trained to assist you with the Lenovo THINKSERVER RD230 Rack Installation Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
RackInstallationInstructions
Guidelines
ThisRackInstallationInstructionsprovidesinformationaboutinstallingyourThinkServer®RD230serverinto
astandardrackcabinetbyusingtherailkitshippedwiththeserver.Ifyounolongerhaveacopyofthis
publication,youcanobtainaPortableDocumentFormat(PDF)versionfromtheLenovo®SupportWebsite
at:
http://www.lenovo.com/support
CAUTION:
Besuretoreadandunderstandthedocumentationthatcomeswiththerackcabinetforsafetyand
cablinginformation.Alsomakesurethatyoureadandunderstandalltherelatedsafetyinformation
fortheserverandreviewtheguidelinesinthispublicationbeforeyouinstalltheserverintoarack
cabinet.Readingandunderstandingtheinformationreducestheriskofpersonalinjuryandor
damagetoyourproduct.
Beforeyouinstalltheserverintoarackcabinet,reviewthefollowingguidelinestohelpyoueaseyour
installationandavoidtheriskofpersonalinjuryandordamagetoyourproduct:
Twoormorepeoplearerequiredtoliftaserver,moveaserver,orinstallaserverintoarackcabinetifthe
servermeetsoneofthefollowingmeasurements:
Theserveris2Uorlarger.(“U”istheunitofmeasurementfordeningtheverticalspaceusedbyyour
serverand1Uisequivalentto4.445cmor1.75inches.)
Theweightoftheserverisratedabove18kg(39.7lbs).Refertothefollowingstatementforsafe
practiceswhenlifting.
18kg(39.7lb)32kg(70.5lb)55kg(121.2lb)
CAUTION:
Usesafepracticeswhenlifting.
Beforeinstallingaserverintoarackcabinet,removeallmediafromthedrivesandturnoffallattached
devicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsanddisconnectall
cablesthatareconnectedtotheserver.
Makesurethattheroomairtemperatureisbelow35°C(95°F).
Donotblockanyairvents;usually15cm(6inches)ofspaceprovidesproperairow.
Donotleaveopenspacesaboveorbelowaninstalledserverinyourrackcabinet.Tohelpprevent
damagetoservercomponents,alwaysinstallablankllerpaneltocovertheopenspaceandtohelp
ensureproperaircirculation.
Installtheserveronlyinarackcabinetwithperforateddoor(s)forbothsecurityandproperairow.
Startfromthebottomoftherackcabinetfortheserverordeviceinstallation.
Installtheheaviestserverordeviceinthebottomoftherackcabinet.
1
Donotextendmorethanoneserverordeviceoutoftherackcabinetatthesametime.
Ifpossible,removethedoorsandsidepanelsoftherackcabinettoprovideeasieraccessduring
installation.
Donotoverloadtheelectricaloutletwhenyouinstallmultipledevicesintherackcabinet.
Connectallpowercordstoproperelectricaloutletsandrefertothedocumentationthatcomeswiththe
rackcabinetforcablinginformationtohelpyouproperlymanageallthecablesintherackcabinet.
Installtheserverinarackthatmeetsthefollowingrequirements:
Note:Itisimportanttoconsiderthelengthoftheserver,thesliderails,andtheadditionalclearancewhen
selectingarackcabinetwithproperdepthbeforetheinstallation.
Standard19-inchrackcongurationasdenedbytheElectronicIndustriesAlliance(EIA)
Canaccommodatetheserverandouterrail
Minimumdepthof7cm(2.76inches)betweenthefrontmountingangeandtheinsideofthefront
door(thisclearanceisrequiredforthebezelandchassispullhandlesonthefrontoftheserveraswell
asaircirculationthroughthecabinet)
Minimumdepthof15.7cm(6.18inches)betweentherearmountingangeandtheinsideoftherear
door(thisclearanceisrequiredforcablingandaircirculationthroughthecabinet)
Payattentiontothefollowingstatement:
CAUTION:
Donotplaceanyobjectontopofrack-mounteddevices.
2
Railkitpackage
Beforeyoubegintherackinstallation,removeallthepartsfromtherailkitpackageshippedwithyour
serverandlayallthepartsonaworkingsurface.
Therailkitpackagecontainsthefollowingparts.Contactyourplaceofpurchaseifanypartismissingor
damaged.
M5+WASHER
M5X20L
M4X4L
Figure1.Partsintherailkitpackage
1Sliderails(2)
2ScrewbagmarkedwithM5+WASHER(containingeightatheadM5x10screwsandeightwashers)
3ScrewbagmarkedwithM5X20L(containingtwopanheadM5x20screws)
4ScrewbagmarkedwithM4X4L(containingfouratheadM4x4screws)
3
Thetwosliderailscontainedintherailkitpackagearethesame.Theillustrationbelowshowsonlythe
componentsofone.
Figure2.Sliderailcomponents
1Frontmountingbracket4Innerrail
2Outerrail5Rearmountingbracket(markedwithREARonbothsides)
3Ballrail(theballbearingrailsandwiched
betweentheouterrailandtheinnerrailto
provideasmoothslidingmovement)
Installingtheserverintoarackcabinet
Toinstalltheserverintoarackcabinet,dothefollowing:
1.Removeallthepartsfromtherailkitpackageshippedwithyourserverandlayallthepartsonaworking
surface.See“Railkitpackage”onpage3.
2.Thestretchingrangeofanouterrailis60cm(23.6inches)to82cm(32.3inches).Measuretherack
beforetheinstallationtoensurethattherackcanaccommodatetheouterrail.
3.Foreachsliderail,separatetheinnerrailfromtheouterrailbydoingthefollowing:
Note:Slidetherailsstraightoutanddonottwisttherailswhenseparatingthem.
4
a.Holdasliderailassemblybyonehandandcarefullyslideboththeballrailandtheinnerrailoutof
thefrontoftheassemblyuntiltheballrailislockedandcannotbepulledoutfurther.
Figure3.Slidingtheballrailwiththeinnerrailoutoftheouterrail
b.Carefullyslidetheinnerrailoutoftheballrailuntiltheinnerrailislockedandcannotbepulledout
further.Then,pressthereleasetab
1ontheinnerrailinthedirectionasshownandcompletely
removetheinnerrailfromtheballrail.
Figure4.Removingtheinnerrailfromtheballrail
5
c.Pressthemetallever1ontheballrailinthedirectionasshownandslidetheballrailbackinto
theouterrail.Theballrailisanintegratedpartoftheouterrailanddonottrytoremovetheball
railfromtheouterrail.
Figure5.Slidingtheballrailintotheouterrail
4.Afterseparatingtheinnerrailsfromtheouterrails,placealltherailsonaworkingsurface.
Figure6.Outerrailsandinnerrails
1Twoouterrails2Twoinnerrails
6
5.Removethetworackhandlesandfourscrewsfromthemountingearkitpackageshippedwithyour
serverandinstalltherackhandlesontheserverbytighteningthescrews.
Note:UseonlyscrewsprovidedbyLenovo.
Figure7.Installingtherackhandles
7
6.Installaninnerrailonthetwomountingstudsononesideoftheserverandthenslidetheinnerrailto
thebackoftheserveruntilitsnapsintoposition.InstalltwoM4x4screwstosecuretheinnerrailonthe
sideoftheserver.Then,installtheotherinnerrailtotheothersideoftheserverinthesameway.
Note:Notetheorientationoftheinnerrails.
Figure8.Installingtheinnerrailstobothsidesoftheserver
Figure9.Installingtheinnerrailstobothsidesoftheserver(sideview)
1Mountingstudholes(2)
2Innerrail
3Screwholes(2)
8
7.Onafrontmountingangeoftherackcabinet,selectaproperrackmountingareafortheserver.Then,
positionthefrontmountingbracket1ofanouterrailontheinsideoftherackmountingarea2.
Note:Theholesinamountingangearedividedintogroupsbymeasuringmarks.Thethreeholes
betweentwoadjacentmeasuringmarksformagroup,whichindicates1Uspace.Notethemeasuring
marksonamountingangetohelpyoucorrectlyselectarackmountingareafortheserver.Formore
informationabouttheplacementoftheholesinamountingange,refertothedocumentationthat
comeswiththerackcabinet.
Figure10.Positioningthefrontmountingbracketoftheouterrailontheinsideoftherackmountingarea
9
8.Makesurethatthefrontmountingbracketisushwiththeverticalmountingsurfaceandthescrew
holesinthefrontmountingbracketarealignedwiththecorrespondingholesintherackmountingarea.
Then,partiallytightentwoM5x10screwswithwasherstoholdthefrontoftheouterrailinposition.
Figure11.TighteningthetwoM5x10screws
10
9.Stretchtherearmountingbrackettothebackoftherackandpositiontherearmountingbracketon
theinsideofthecorrespondingrackmountingareaontherearmountingange.Makesurethefront
endandrearendoftheouterrailareatthesamehorizontallevelandthetwoscrewholesintherear
mountingbracketarealignedwiththecorrespondingholesintherackmountingarea.Then,rmly
tightentwoM5x10screwswithwasherstosecuretheouterrailinplace.
Figure12.Securingtherearmountingbracketontherearmountingange
10.Returntothefrontmountingangeandrmlytightenthetwoscrewsthatholdthefrontoftheouterrail.
11.Repeatsteps6through9toinstalltheotherouterrailtotheoppositesideoftherack.
11
12.Fullyextendtherailsonbothsidesoftherackbyslidingtheballrailsoutofthefrontoftheouterrails
untiltheballrailsarelockedandcannotbepulledoutfurther.Youshouldhearaclickwhentheballrails
arelocked.Then,checkthefrontendsoftheballrailstoensuretheinnersideofeachballrailislocked
inpositionbythesmallmetallever
1beforeyouinstalltheserverintotherack.
Figure13.Fullyextendingtherailsonbothsidesoftherack
13.Liftuptheservernowequippedwithrackhandlesandinnerrailsonbothsidesandcarefullyinsertthe
innerrailsintotheextendedballrails.Then,slidetheinnerrailsstraightintotheballrailsuntiltheinner
railsarestoppedbytheretentiontabs.
Notes:
a.Beforeliftingupyourserver,see“Guidelines”onpage1todeterminewhethertwoormorepeople
arerequired.Strictlyfollowtheguidelinesforsafelifting.
b.Donotforcetheinnerrailsintotheballrails.Whentheyarealignedproperly,theywillengage
smoothly.
c.Youmustsupporttheserverfromthebottomtopreventitfromdroppingandensurethatitslidesin
horizontally.
12
Figure14.Slidingtheserverwithinnerrailsintotheballrails
13
14.Whentheinnerrailshavebeenstopped,presstheretentiontabs1onbothsidesinthedirectionas
shownandcontinuegentlyslidingtheserverintotherackuntilitisfullyseated.
Figure15.Pressingtheretentiontabsandslidingtheserverallthewayintotherack
14
15.Tosecuretheserverintherack,installoneM5x20screwthroughtherackhandleonbothsidesofthe
server.Afterinstallingthescrews,theserverissecurelyseatedintherackandcannotslideoutunless
youremovethescrews.Thisensuressafetyandsecurity,especiallyinvibration-proneareas.
Figure16.Securingtheserverintherack
Toremovetheserverfromtherack,reversetheseinstructions.Storethisinformationwithyourserver
documentationforfutureuse.
15
FirstEdition(December2010)
©CopyrightLenovo2010.
LENOVOproducts,data,computersoftware,andserviceshavebeendevelopedexclusivelyatprivateexpenseandare
soldtogovernmentalentitiesascommercialitemsasdenedby48C.F.R.2.101withlimitedandrestrictedrightsto
use,reproductionanddisclosure.
LIMITEDANDRESTRICTEDRIGHTSNOTICE:Ifproducts,data,computersoftware,orservicesaredeliveredpursuant
aGeneralServicesAdministration“GSAcontract,use,reproduction,ordisclosureissubjecttorestrictionssetforth
inContractNo.GS-35F-05925.
PrintedinChina
(1P)P/N:91Y1795
*91Y1795*
16
/