MULTIPLEX 5428 Support Stand (EI542800) is a sturdy and versatile stand designed to support and elevate Model 50 Refrigeration Units. It features a robust construction with a top frame assembly and leg assemblies secured by hex head screws and gusset plates. The stand provides a stable base for the refrigeration unit, ensuring its secure placement during operation. It also allows for easy access to the unit for maintenance and service. Additionally, the stand includes adjustable bottom leg levelers, enabling precise leveling on uneven surfaces.

MULTIPLEX 5428 Support Stand (EI542800) is a sturdy and versatile stand designed to support and elevate Model 50 Refrigeration Units. It features a robust construction with a top frame assembly and leg assemblies secured by hex head screws and gusset plates. The stand provides a stable base for the refrigeration unit, ensuring its secure placement during operation. It also allows for easy access to the unit for maintenance and service. Additionally, the stand includes adjustable bottom leg levelers, enabling precise leveling on uneven surfaces.

Instructions
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
EI542800
8/09
Subject: Model 5428 Support Stand
HOW TO ASSEMBLE THE MODEL 5428 SUPPORT STAND
1. Lay the Top Frame Assembly on the floor and attach the Leg Assemblies using 1/4"-20 x 1/2" Hex Head Screws and
Gusset Plates as shown in figure 1.
2. Turn the stand upright and install 5/8"-11 x 3" Hex Screws in each corner (refer to figure 2).
3. Place stand in the desired location and level by adjusting the bottom leg levelers.
4. Mount the Model 50 Refrigeration Unit on the stand. Secure with 5/8"-11 x 3" Hex Screws (refer to figure 2).
5. Place the second Model 50 Refrigeration Unit on the service dolly. Secure with 5/8"-11 x 3/4" Hex Screws at each corner
as shown below.
6. Position the second Model 50 Refrigeration Unit under the support stand. Connect the flexible utilities to permit the unit to
be rolled out approximately 2 to 3 ft for service access.
7. Provide suitable means to limit roll-out distance so the flexible utility connections are not overly stressed (chain or wheel
chocks).
Model 5428 Support Stand EI542800
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
DO Adhere to all National and Local Plumbing and Electrical Safety Codes.
DO Turn “Off” incoming electrical service switches when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation tank(s) are tight. This check should be performed with a
wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of all equipment.
DO Handle C0
2 cylinders and gauges with care. Secure cylinders properly against abrasion.
DO Store C0
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a C0
2 cylinder. Secure the cylinder(s) in an upright position with a chain.
DO NOT Connect the C0
2 cylinder(s) directly to the product container. Doing so will result in an explosion causing
possible death or injury. Best to connect the C0
2 cylinder(s) to a regulator(s).
DO NOT Store C0
2 cylinders in temperature above 125˚ F (51. 7˚ C) near furnaces, radiator or sources of heat.
DO NOT Release C0
2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of 200
˚ F (93.3˚ C).
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained in accordance with Federal, State, and Local codes.
!
Caution
To Avoid Serious Injury Read the following warnings before
beginning an installation. Falure to do so may result in possible
death or serious injury.
!
Warning
DANGER OF ELECTRICAL SHOCK - Disconnect and lock out all
electrical power sources before performing service or maintenance on
this machine -- except when electrical tests are being performed by
qualified service personnel.
  • Page 1 1
  • Page 2 2

MULTIPLEX 5428 Support Stand Installation guide

Type
Installation guide
This manual is also suitable for

MULTIPLEX 5428 Support Stand (EI542800) is a sturdy and versatile stand designed to support and elevate Model 50 Refrigeration Units. It features a robust construction with a top frame assembly and leg assemblies secured by hex head screws and gusset plates. The stand provides a stable base for the refrigeration unit, ensuring its secure placement during operation. It also allows for easy access to the unit for maintenance and service. Additionally, the stand includes adjustable bottom leg levelers, enabling precise leveling on uneven surfaces.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI