  • Hello! I am an AI chatbot trained to assist you with the MULTIPLEX Wall Mounted Primary CO2 EI217420 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Instructions
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
EI217420
8/09
Subject: Wall Mounted Primary C02 Regulator Kit - P.N.00217420
INSTALLING THE WALL MOUNTED PRIMARY C02 REGU LATOR KIT
1. Assemble the Regulator Guard and the Wall Bracket to the Primary C0
2 Regulator as shown in figure 1. To
provide the maximum clamping force, omit the bolt sleeve when assembling the center bolt.
2. Mount the assembly to a convenient position on the wall adjacent to the C0
2 Bottle Tank. Screws provided may be
used for wood or metal surfaces. Drill 5/32" pilot holes.
3. Connect the C0
2 bottle to the Regulator with the Line Assembly. If necessary, use a fibre washer at the C02 bottle
connection.
NOTE: For C0
2 tanks with metric threads, replace swivel nut on the line assembly with nuts provided in kit.
Wall Mounted Primary C02 Regulator Kit - P.N.00217420 EI217420
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
DO Adhere to all National and Local Plumbing and Electrical Safety Codes.
DO Turn “Off” incoming electrical service switches when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation tank(s) are tight. This check should be performed with a
wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of all equipment.
DO Handle C0
2 cylinders and gauges with care. Secure cylinders properly against abrasion.
DO Store C0
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a C0
2 cylinder. Secure the cylinder(s) in an upright position with a chain.
DO NOT Connect the C0
2 cylinder(s) directly to the product container. Doing so will result in an explosion causing
possible death or injury. Best to connect the C0
2 cylinder(s) to a regulator(s).
DO NOT Store C0
2 cylinders in temperature above 125˚ F (51. 7˚ C) near furnaces, radiator or sources of heat.
DO NOT Release C0
2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of 200
˚ F (93.3˚ C).
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained in accordance with Federal, State, and Local codes.
!
Caution
To Avoid Serious Injury Read the following warnings before
beginning an installation. Falure to do so may result in possible
death or serious injury.
!
Warning
DANGER OF ELECTRICAL SHOCK - Disconnect and lock out all
electrical power sources before performing service or maintenance on
this machine -- except when electrical tests are being performed by
qualified service personnel.
/