  • Hello! I've reviewed the user manual for the Super Bright LEDs LPD7 series LED Panel Lights, including models LPD7 xK22-40, LPD7 xK24-50, and LPD7 xK24-72. This manual provides detailed instructions for safe installation, wiring, and mounting in a drop ceiling using safety tabs. I'm ready to answer your questions about these lights.
  • Who should install this product?
    What should be done before starting installation?
    Is a safety cable included?
Dimmable LED Panel Light
Important: Read all instructions prior to installation. LPD7 Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V1 09/15/2022
5yr
User Manual
Wiring
Safety and Notes
Recommended Accessories
Product should be installed by a certied electrician in accordance with
applicable national, state, and local building and electrical codes.
To reduce the risk of electric shock, ensure that the main power source and
circuit breakers are switched o before performing any installation or wiring
procedures.
Avoid looking directly into the light when illuminated.
Failure to properly support the xture may result in damage or injury, for which
the manufacturer does not assume responsibility. A safety cable is not included,
but it is recommended that one be connected to grid clip during installation.
Specications
LPD7-40K24-50
Check product label for specific electrical
specifications related to installation.
Improper installation will void warranty.
Model LPD7-xK22-40 LPD7-xK24-50 LPD7-xK24-72
Operating Temperature 14°–95° F (-10°–35° C)
IP Rating IP20
0–10 V Slide Dimmer (F019)
0–10 V Knob Dimmer (A019)
Neutral (white)
Line (black)
Ground (green)
Dim- (gray)
Dim+ (purple)
Dimmable LED Panel Light
Important: Read all instructions prior to installation. LPD7 Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V1 09/15/2022
5yr
User Manual
Drop Ceiling Installation
1. Turn supply power to circuit o. If installing as a retrot, remove existing xture.
2. Open driver box and remove knockout(s) for wiring. Make electrical connections
using wiring diagram. Once complete, resecure driver box cover.
3. For each safety tab, bend tab to be vertical, then bend upper portion out 90
degrees.
4. Lay xture into T-grid.
Note: Tabs should secure light in
T-grid while still allowing reinstallation
of adjacent ceiling tiles.
FIG 2
FIG 1
Safety Tab
Driver Box
Fixture
T-Grid
Firmly bend Safety Tabs
up and out
Safety Tab
/