Focal Point ID+ 4.5" Wall Wash Trimless FLC4W-RT Installation guide

Type
Installation guide

This manual is also suitable for

IS0607 REV. B 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4
id+ 4.5” round trimless housing
FLC4D-RT | FLC4W-RT
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
non-emergency - thermally protected, non-ic
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING.
emergency - integral test switch
Flc4d-rt | Flc4w-rt
Flc4d-rt | Flc4w-rt
cp - emergency/non-emergency
Flc4d-rt | Flc4w-rt
key
power oFF power on
level attention
see additional instructions
bar hangers
sold separately
WALL WASH ORIENTATION
WALL
5 3/4min
6 1/4max
1A
TO SET CEILING
THICKNESS SEE FOCAL
POINT INSTRUCTION SHEET
IS0609
X2
2
3WOOD STUDS
2b x4
2a x4
IS0607 REV. B 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4
Fixtures must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
make electrical connections
5
4
METAL STUDS
x4
3
MUD-IN
4
DO NOT REMOVE DUST
COVER UNTIL TAPE AND
MUD-IN COMPLETE
5
5 3/4min
6 1/4max
1
CLEAN CEILING SURFACE FREE
OF DUST AND DEBRIS
2
REMOVE ADHESIVE BACKING FROM MUD RING
3
USE DUST COVER TO ALIGN MUD RING
WITH HOUSING
MUD TAPE
DRYWALL
IS0607 REV. B 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4
Fixtures must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
WOOD CEILING
wood ceiling installation kit parts list
5/16" miniature
rabbeting bit with
1/16" cut depth
wood routing jig
3m command poster strip
#136 (qty. 40)
2 3
ADHERE COMMAND POSTER STRIPS
TO WOOD ROUTING JIG
ADHERE WOOD ROUTING JIG
TO WOOD CEILING SURFACE 4CREATE STARTER HOLE
X4
4”
1
CLEAN WOOD CEILING SURFACE
AND WOOD ROUTING JIG FREE
OF DUST AND DEBRIS
.065”
Trim Recess
8a 9
CREATE TRIM RECESS
USING RABBETING BIT
SET DEPTH OF RABBETING BIT
USE TRIM TO DOUBLE CHECK DEPTH
8b
5CREATE MAIN HOLE USING
WOOD CEILING JIG AS GUIDE 6REMOVE WOOD ROUTING JIG
FROM WOOD CEILING SURFACE 7
INSTALL 5/16" MINIATURE RABBETING BIT
WITH 1/16" CUT DEPTH
5"
Contractor is responsible for adequately reinforcing walls and/or ceilings to support xture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or
ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0607 REV. B 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4
DRIVER SERVICE
1
EMERGENCY - INTEGRAL TEST SWITCH
DO NOT MATE CONNECTOR
UNTIL INSTALLATION
IS COMPLETE AND A.C.
POWER IS SUPPLIED
A B
BATTERY UNIT CONNECTOR INSIDE
SEE BATTERY
MANUFACTURER
INSTRUCTIONS
FOR EMERGENCY INTEGRAL
TEST SWITCH INSTALLATION
SEE FOCAL POINT
INSTRUCTION SHEET IS0609
C
CP HOUSING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Focal Point ID+ 4.5" Wall Wash Trimless FLC4W-RT Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI