Focal Point ID+ 2" Cylinder Wall Wash Surface Mount FLCY2W Installation guide

Type
Installation guide

This manual is also suitable for

©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1 of 5
IS0815 REV. B
ID+ 2" Cylinder - Surface Mount
FLCY2
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY
3.55"
90.2mm
1.56"
39.6mm
3.50"
88.9mm
4.00"
101.6mm
" OCTAGONAL JBOX REQUIRED EMERGENCY
PRIOR TO LUMINAIRE INSTALLATION,
SEE PAGE  FOR EMERGENCY
INSTALLATION INSTRUCTIONS.
J-BOX BY OTHERS
SHALLOW CANOPY
DECORATIVE SHALLOW CANOPY
HARDWARE KIT
A58700-01
CANOPY
CANOPY
HARDWARE KIT
A58700-01
DECORATIVE
J-BOX COVER
SURFACE MOUNT
CYLINDER
MOUNTING
SCREWS
#72029
2 of 5
IS0815 REV. B ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
5b4 11
5a
321
1
2
43
HARDWARE
BY OTHERS
SHALLOW CANOPY
DECORATIVE SHALLOW CANOPY
1 32
4
MAKE ELECTRICAL CONNECTION
TIGHTEN SET SCREW TO SECURE CYLINDER
IDENTIFY KNOCKOUT COVER(S)
TO BE REMOVED FOR CONDUIT ACCESS
GENTLY PRY UP TO REMOVE
KNOCKOUT COVER
3 of 5
IS0815 REV. B ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
6 87
9
MAKE ELECTRICAL CONNECTION
TIGHTEN SET SCREW TO SECURE CYLINDER
1 2 3
FLCY  DRIVER SERVICE
4
LOOSEN SET SCREW BEFORE STEP 
4 of 5
IS0815 REV. B ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
FLCY  OPTIC SERVICE
1
432
DISTRIBUTION KITS INCLUDE AN
OPTIC AND REFLECTOR ASSEMBLY.
BOTH ITEMS MUST BE USED
TO ACHIEVE SPECIFIED
DISTRIBUTION.
FLCY  WALL WASH AIMING
2 3
ROTATE INNER BEZEL TO ADJUST REMOVE AIM ASSIST INSERT
1
5 of 5
IS0815 REV. B ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
3 4
EMERGENCY
1
SECURE TO STRUCTURE ABOVE
2
MAKE ELECTRICAL CONNECTION
SEE BATTERY MANUFACTURER
INSTRUCTIONS
EMERGENCY MAXIMUM MOUNTING HEIGHT:
" CYLINDERS  .'
HARDWARE
BY OTHERS
PROCEED TO
LUMINAIRE INSTALLATION
PAGE 
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Focal Point ID+ 2" Cylinder Wall Wash Surface Mount FLCY2W Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI