METTLER TOLEDO SQC16 Chapter 4: Getting to know the SQC16 software
17
4 Getting to know the SQC16 software
SQC16 is an application for the 4-Series Compact Scales / Terminals. It is a convenient SQC compact system.
This chapter describes working with the SQC16 application. You might consider consulting Chapter
0 first about how to
specify the behavior of the scale during weighing to match the surroundings. Further, you can specify general options
such as scale identification, date, time, etc.
The SQC16 compact system offers evaluation and monitoring possibilities to statutory requirements for the fields of filling
process control. It is suggested to attach a suitable METTLER TOLEDO strip printer or A4/Report printer.
Note: For more information about the meaning of the expressions 'Adjustment', 'Batch Statistics', 'Global Density',
'Individual Tare', 'Plausibility Limits', 'Mean Value Requirements', 'Shared Statistics', 'Supplement', 'Test', 'Tolerance
System', 'Violation Check', 'Weighing Mode' and '2
nd
Tolerance System' please consult the included CD and select
'Appendix' of the 'SQC16 Training'. Alternatively, open the file Appendix_E.pdf on the root of the CD.
Special features of the system:
Internal calibration weight available as option
Language a choice of 11 languages
Max. number of articles 300
Data backup/restore/edit
Statistics printing convenient also under MS Windows 98/ME/NT/2000/XP
Bar code for simple and effortless article selection
Tolerance systems EU, Free1, Free2, Free3
Units g, kg, lb, oz, ml, l, fz
Statistics per article 2 sets of statistics closed manually, e.g. for hourly and daily statistics
Batch statistics printed and closed automatically at end of batch
A4/Letter report printing choose between the Complete or Compact printing
Histogram in sample record and statistics
Class table in sample record and statistics
Graphics x/R (mean value/range) or x/s (mean value/standard deviation) in sample record
and statistics
Additive or subtractive weighing for simple handling
Minimum nominal support checking of the nominal value (warning if less than 100 resolution steps are
defined)
Individual tare for tare weights with high standard deviation (i.e. wide scatter)
Mean tare enter manually or by weighing a tare series or bulk tare
Sample size max. 999 (Note: with individual tare, there are 50 pre-weighing values available
for each of max. 20 articles simultaneously)
Plausibility check selectable (for nominal: for each article / for tare: system wide)
Adjustment to get suitable adjustment messages for the filling machine
Violation check for alarms after various defined events (T1-, T2-Violators below defined amount,
etc.)