Xpelair DX100 Installation And Maintenance Instructions Manual

Category
Household fans
Type
Installation And Maintenance Instructions Manual
DX100R (93005AW)
DX100S (93025AW)
DX100TR (93006AW)
DX100TS (93026AW)
DX100PR (93007AW)
DX100PS (93027AW)
DX100HTR (93008AW)
DX100HTS (93028AW)
Xpelair Simply Silent
DX100
In
stallation and Maintenance Instructions
EnglishNederlands
ُ
ِ
َ َ
DX100HPTR (93009AW)
DX100HPTS (93029AW)
DX100PIRR (93010AW)
DX100PIRS (93030AW)
Xpelair Simply Silent
DX100
Installation and Maintenance Instructions
Installation and Maintenance Instructions
Installatie - en Onderhoudsinstructies
Doreadtheentireinstructionleaetbeforecommencinginstallation.
Doinstalleachfanwithameansfordisconnectioninallpolesinthexedwiring.
Domakesurethemainssupplyisswitchedobeforeattemptingtomakeelectrical
connectionsorcarryoutanymaintenanceorcleaning.
Pleaseleavethisleaetwiththefanforthebenetoftheuser.
Standard
DX100R (93005AW)
DX100S (93025AW)
Timer
DX100TR (93006AW)
DX100TS (93026AW)
PullCord
DX100PR (93007AW)
DX100PS (93027AW)
Humidistat,Timer
DX100HTR (93008AW)
DX100HTS (93028AW)
Humidistat,PullCord,Timer
DX100HPTR (93009AW)
DX100HPTS (93029AW)
IntegralBodyMovementSensor
DX100PIRR (93010AW)
DX100PIRS (93030AW)
Installation and Maintenance Instructions
English
Thisapplianceisintendedfor
connectiontoxedwiring.Check
thattheelectricalratingshownon
eachfanmatchesthemainssupply.
THE APPLIANCE IS DOUBLE INSULATED
AND DOES NOT REQUIRE AN EARTH
CONNECTION. Allinstallationsmustbesupervised
byaqualiedelectrician.Installationsandwiring
mustconformtocurrentIEERegulations(UK),local
orappropriateregulations(othercountries).
This appliance can be used
by children aged from 8 years
and above and persons with
reduced physical, sensory
capabilities or lack of
experience and knowledge
if they have been given
supervision or instruction
concerning the use of the
appliance in a safe way and
understand the hazards
involved. Children shall not
play with the appliance.
Cleaning and maintenance
of the appliance shall not be
made by children.
AllXpelairSimplySilent™DX100AC
fanshavethefollowingfeatures:
Twospeedextraction
(Selectableatinstallation)
DX100R/DX100S - Operatethefanusingan
on/oswitch(notsupplied).
DX100TR/DX100TS* - Built-intimeroperatesfan
forapresetdelayfrom30secondsto30minutes.
DX100PR/DX100PS - Operatethefanusingan
integralpull-cord.
DX150HTS/DX150HTR* - Operateswhentriggered
automaticallybytheintegralhumiditysensor,orby
usinganexternalon/oswitch(notsupplied).
In automatic mode: thebuilt-intimerautomatically
operatesthefanforapre-setdelaytimefrom30
secondsto30minutesoncehumiditydropsbelow
thepre-setRelativeHumidity(RH)value.
External operation:Whenswitchedousingthe
externalon/oswitchthefancontinuestorunfor
thepresetdelayfrom30secondsto30minutes.
DX100HPTR/DX100HPTS* - Operateswhen
triggeredautomaticallybytheintegralhumidity
sensor,byusinganexternalon/oswitch(not
supplied),orbyusingtheintegralpullcordswitch.
In automatic mode: Thebuiltintimerautomatically
operatesthefanforthepre-setdelaytimefrom30
secondsto30minutesoncehumiditydropsbelow
thepre-setRelativeHumidity(RH)value.
External operation:Whenswitchedousing
eithertheexternalon/oswitchortheintegral
pullcordswitchthefancontinuestorunforthe
pre-setdelayfrom30secondsto30minutes.
DX100PIRR/DX100PIRS* - Anintegralbody
movementsensoroperatesthefanaslong
asmovementisdetected.Thebuilt-intimer
automaticallyoperatesthefanforapre-setdelayof
upto20minutes.
* Factory settings: Timer 15 minutes, RH 75%
Where to locate the fan.
Locateitashighaspossible.
Atleast110mmfromtheedgesof
themountingsurfacetothecentre
ofthehole.
Asfarawayaspossiblefromandoppositeto
themainsourceofairreplacementtoensure
airowacrosstheroom(e.g.oppositethe
internaldoorway).
Nearthesourceofsteamorodours.
• Notwhereambienttemperatures
are likely to exceed 50°C.
Ifinstalledinakitchen
fans must not be mounted
immediately above a cooker
hob, or eye level grill.
• Ifinstallinginaroomcontainingafuelburning
device which has a non-balanced flue, it is the
installer’s responsibility to ensure that there
is enough replacement air to prevent fumes
being drawn down the flue when the fan is
operating up to maximum extract. Refer to
Building Regulations for specific requirements.
• Exhaustairmustnotbedischargedinto
a flue used for exhausting of fumes from
appliances supplied with energy other than
electric. Requirements of all authorities
concerned must be observed for exhaust air
discharge and intake flow rates.
• Notsuitableforuseinpossiblechemical
corrosive atmospheres.
Installation
What the installer will need.
3mmelectrician’sscrewdriver
andNo.1or2Pozidrive
screwdrivers.
English
Overall Dimensions (mm)
Back plate
fixing positions
A B
Front Cover Removal
C D
DEPRESSCOVERLATCHWITHTOOL
&REMOVECOVERCOMPLETE
English
3.0
2.0
1.0
0
1.0
2.0
3.0
1.0 2.0 3.0 4.0 5.0 6.0 (m)
1.0 2.0 3.0 4.0 5.0 6.0 (m)
(m)
(m)
90˚
60˚
4.0
3.0
2.0
1.0
0
Horizontaldetectionarea
3.0
2.0
1.0
0
1.0
2.0
3.0
1.0 2.0 3.0 4.0 5.0 6.0 (m)
1.0 2.0 3.0 4.0 5.0 6.0 (m)
(m)
(m)
90˚
60˚
4.0
3.0
2.0
1.0
0
Verticaldetectionarea
Wiring and setting up
G1
SEEDETAILA
DX100R / DX100S
DX11PR/DX100PS
DX100TR / DX100TS
CUSTOMER
CONNECTION
TERMINAL
English
IMPORTANT – PLEASE READ
Adjusting the humidity setting
Adjusting the run on timer setting
Fanswitcheson
atlowerlevelof
condensation
(anti-clockwise)
MORESENTITIVE
(RH=50%)
Fanrunsonfora
shortertimewhen
theexternalswitch
isturnedo
Fandoesnot
switchonuntil
higherlevelof
condensation
(clockwise)
LESSSENTITIVE
(RH=95%)
Fanrunsonfora
longertimewhen
theexternalswitch
isturnedo
Factory settings:
Timer15minutes,RH75%
Maximum30minutesMinimum30seconds
FE
SEEDETAILB
SEEDETAILC
CUSTOMER
CONNECTION
TERMINAL
DETAIL A
SCALE 2.000
HIGH
SPEED
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
LOW
SPEED
DETAIL C
SCALE 2.000
DETAIL B
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
HIGH
SPEED
LOW
SPEED
OVER-RUN
TIMER
LEVELLINE
LEVELLINE
Wiring and setting up
G2
G3
DX100HTR / DX100HTS
DX100HPTR / DX100HPTS
DX100PIRR / DX100PIRS
CUSTOMER
CONNECTION
TERMINAL
English
SEEDETAILG
SEEDETAILF
CUSTOMER
CONNECTION
TERMINAL
CUSTOMER
CONNECTION
TERMINAL
DETAIL G
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
LOW
SPEED
HIGH
SPEED
DETAIL H
SCALE 2.000
DETAIL I
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
LOW
SPEED
HIGH
SPEED
DETAIL E
SCALE 2.000
DETAIL D
SCALE 2.000
DETAIL F
SCALE 2.000
SETJUMPERTO
REQUIREDPOSITION
FORSPEEDSETTING
HIGH
SPEED
LOW
SPEED
SEEDETAILD
SEE
DETAILE
OVER-RUN
TIMER
HUMIDISTAT
OVER-RUN
TIMER
HUMIDISTAT
SEEDETAILI
SEEDETAILH
OVER-RUN
TIMER
LEVELLINE
LEVELLINE
LEVELLINE
English
If wall mounting the fan, you will also need:
• A100mmdiameterpreparedhole.
• AnappropriateexternalWallGrilleand
Ø100mmwallsleeveduct(supplied).Cut
ductingtocorrectlengthifrequired.The
walltubesuppliedistelescopicandcanbe
extendedto300mmmaximum.
If ceiling mounting the fan, you will also need:
• A100mmdiameterpreparedhole.
• A100mmdiameterpreparedholeforthe
externalgrille,ideallypositionedtoallow
condensationtorunawayfromtherstbend
intheducttowardstheexternalgrille.
• Appropriateancillariesfortermination.These
itemsareavailablefromXpelair:
1.3mexibleductingRef:89663AA.Ifthe
ductpassesthroughacoldspaceuse
insulatedductref:89847AA.
2.SotGrilleRef:89742AW
If window mounting the fan, you will also need:
• SSWIN-SimplySilentWindowKit.
Ref:92996AA
Installing the isolating switch
and cables.
Ameansfordisconnectioninallpoles
mustbeincorporatedinthexedwiring
inaccordancewithwiringregulations
• Ifmetalswitchboxesareused,earthing
regulations must be followed.
• Thecross-sectionalareaofthesupplycord
usedshouldberangedfrom1-1.5mm².
• DX100R/DX100S/DX100PR/DX100PS/
DX100PIRR/DX100PIRS–2core,
• DX100TR/DX100TS/DX100HTR*/
DX100HTR*/DX100HPTR*/DX100HPTS*–
3core.*Ifwiringtoremoteswitch.
1.Checkthattheelectricalratingshowninside
theback-platematchesyourmainssupply.
2.Checktherearenoburiedpipesorcables
e.g.electricity,gas,waterbehindtheswitch
location(inthewallorabovetheceiling).Ifin
doubt,seekprofessionaladvice.
3.Isolatethemainssupply.
4.Layinthecablefromtheisolatingswitch
tothefanlocationviatheon/oswitch(if
required).
5.Layinthecablefromtheisolatingswitchto
thepointofconnectiontothemainssupply.
Warning: Do not make any
connections to the electrical supply
at this stage.
6.Installtheisolatingswitchandon/oswitch
(ifrequired).
7.Makeallconnectionswithintheisolating
switchandtheon/oswitch(ifrequired).
Wet Rooms: On/Off switch must
be situated so that it cannot be
touched by persons making use of
the bath or shower.
For Australia Only – DX100R / DX100S
/ DX100PR / DX100PS / DX100PIRR /
DX100PIRS Connectiontothesupplycanbe
madebyaexible2-corecablecompletewith
3pinplugforinsertionintoanapproved10A
GPOordirectlywiredthroughanapproved10A
wallmountedsurfaceswitchwithatleast3mm
clearancebetweencontacts.
For Australia Only –DX100TR / DX100TS
/ DX100HTR / DX100HTS / DX100HPTR /
DX100HPTS Thesemodelsarepermanently
connectedtothesupplyandoperationis
controlledbyaremoteswitch.Theyshould
bedirectlywiredtothesupplythroughan
approved10Awallmountedsurfaceswitch
withatleast3mmclearancebetweencontacts.
Preparing the Fan for installation.
1. Removethefrontcoverbydepressingthe
latchontheundersideofthecoverand
pullingothefrontcoverfromthebottom
(SeeFigureC).
If working above ground floor
level, safety precautions must be
observed.
Mark the position of the back-plate
2. Holdtheback-platesothatthelevelline
markedonitisorientatedhorizontally.
3. Carefullyinsertthefantubeintothewallduct.
4. Markonthewallthepositionsofthexing
holesintheback-plate.
5. Removethebackplatefromtheducting.
6. Drillscrewholesinthesepositionsifnecessary,
andtwallplugsandscrewsasrequired.
If installing in a ceiling, appropriate
termination ancillaries are required.
Follow instructions provided.
Mount the back-plate.
7. Pushtheribbedgasketontotheduct
sectionofthebackplate(seeFigureD).
8. Pushthelargerdiameterpieceofthetelescopic
walltubeontotheribbedgasket.Cutthetube
totherequiredsizerstifnecessary.
9. Feedthemainscablethroughthecable
entryholeinthebackplatetotheterminals.
10. Insertthefantubeintothewallduct/ceiling
asbefore.
11. Fastentheback-platetothewall/ceiling
usingappropriatefastenerssupplied.See
gureA.
12. Ifusingscrews,donotovertighten.
Mount the back draft shutter
13. Peelthebackingfromthefoamstrip
suppliedandattachitaroundtheoutsidelip
onthebackdraftshutter.
14.Gooutside.Holdingopenthetopandbottom
vanesinsertthelipintothewallduct.
15. Makingsurethatthebackdraftshutteris
level,markthepositionsofthetwoxing
holesinthetoprighthandandbottomleft
handcorners.
16. Removethebackdraftshuttersfromthe
wallduct.
17. Drillscrewholesinmarkedpositionsandt
theremainingwallplugs.
18. Holdingopenthetopandbottomvanes,
retthebackdraftshutterandfasten
ittothewallusingthescrews.Donot
overtightenscrews.
19.Makesurethatthevanesopenandshutfully.
Wire the electrical connections.
20. Makesurethemainssupplyisisolated.
Switchothemainselectricalsupplyand
removefuses.
21. Feedthecabletotheterminalblock.Wire
thefanasshowninFigureHusingthe
diagramappropriatetothefanmodel.
22. Connectthecablefromtheisolatingswitch
totheelectricalsupplywiring.
English
DX100R/DX100S
DX100PR/DX100PS
DX100PIRR/DX100PIRS
DX100TR/DX100TS
DX100HTR/DX100HTS
DX100HPTR/DX100HPTS
H
FAN
TERMINALS
FAN
TERMINALS
FAN
TERMINALS
DOUBLEPOLE
ISOLATINGSWITCH
DOUBLEPOLE
ISOLATINGSWITCH
DOUBLEPOLE
ISOLATINGSWITCH
ON/OFF
SWITCH
(OPTIONAL)
ON/OFF
SWITCH
(REQUIRED)
LAMP
(IFREQUIRED)
LAMP
(IFREQUIRED)
FUSE
FUSE
FUSE
For fixed wiring circuits the protective fuse
for the appliance must not exceed 5A.
English
Fan Settings
SPEED SETTING
Thefansarefactorysettolowspeed,buthave
twospeedsettingsfordierentapplications.
Selecteitherhighorlowspeedbyconnecting
thejumperbetweenthecentreandhighorlow
speedpinonthejumper(seeFigureG).
DX100TR / DX100TS / DX100PIRR /
DX100PIRS only.
Toadjusttheover-runperiodturnthecontrol
(T)clockwisetoincreaseandanti-clockwise
todecrease–seeFigureF.
DX100HTR / DX100HTS / DX100HPTR /
DX100HPTS only – see figures F and G.
Thepre-sethumidityoperationisfactoryset
atapproximately75%RelativeHumidity(RH),
butcanbeadjustedbetween65%and85%
RHbycontrolH.
Theover-runtimerisfactorysetat15minutes
butcanbeadjustedfrom30secondsto30
minutesbycontrolT.
TurnthecontrolsclockwisetoincreaseRHor
timeandanti-clockwisetodecrease.
Using the fan
DX100R / DX100S Only
Operatethefanusingtheon/oswitch(not
supplied).Repeattoswitcho.
DX100TR / DX100TS Only
Operatethefanusinganon/oswitch(not
supplied).Note–thefanmaytakeupto10
secondstoturnononcetheswitchhasbeen
operated.Whentheswitchisturnedo,
thefancontinuestooperateforthesettime
delay.Toadjusttheover-runperiod,turnthe
control“T”clockwisetoincreaseandanti-
clockwisetodecrease–seeFigureF.
DX100PR / DX100PS Only
Operatethefanbypullingandreleasingthe
cord.Repeattoswitcho.
DX100HTR / DX100HTS Only.
Automatic mode-Thefanautomatically
adjuststoslowchangesinnaturalhumidity
levelswithoutoperatingthefan.Ifthe
humiditylevelsincreaseatarateslower
than5%RHin5minutes,uptothepre-set
humiditylevel,thefanwillnotbetriggered
byhumidity.Thisistopreventnuisance
triggeringofthefan.Ifhumiditylevels
increasequickerthan5%RHin5minutes
thefanwilloperate.Whenrelativehumidity
dropsthefancontinuestooperateforthe
adjustabletimedelay.
External operation-Usetheexternalon/o
switch.Whenthefanisswitchedo,thefan
continuestooperatefortheadjustabletime
delaythengoesintoautomaticmode.
DX100HPTR / DX100HPTS Only.
• Automatic mode-Thefanautomatically
adjuststoslowchangesinnaturalhumidity
levelswithoutoperatingthefan.Ifthehumidity
levelsincreaseatarateslowerthan5%RH
in5minutes,uptothepre-sethumiditylevel,
thefanwillnotbetriggeredbyhumidity.This
istopreventnuisancetriggeringofthefan.If
humiditylevelsincreasequickerthan5%RH
in5minutesthefanwilloperate.Whenrelative
humiditydropsthefancontinuestooperatefor
theadjustabletimedelay.
External operation-Usetheexternalon/o
switch.Whenthefanisswitchedo,thefan
continuestooperatefortheadjustabletime
delaythengoesintoautomaticmode.
Pull Cord operation–Usetheintegralpull
cordswitch.Whenthefanisswitchedo,the
fancontinuestooperatefortheadjustable
timedelaythengoesintoautomaticmode.
DX100PIRR / DX100PIRS Only.
Thesensordetectsmovementintheroom
andactivatesthefan.Whenmovementis
sensed,thefanwillrunforapre-setover-run
periodandanyfurthermovementsensed
willre-startthesequence.Thisensures
thattheroomisonlyventilatedduringand
immediatelyafteruse.Whenthefanisrst
installeditwillrunforthetimesetbythe
overruntimer.Afterthistime,ifnomovement
issensedthefanwillgointostand-bymode.
All Fans
Re-tthefrontcoverbyhookinginthetoprst,
andthenswingthecoverdowntoclipintoplace.
English
Cleaning
(recommendedonceamonth)
1.Beforecleaning,isolatethefancompletely
fromthemainssupply.
2.Removethefrontcoverbydepressingthe
latchontheundersideofthecoverand
pullingothefrontcoverfromthebottom.
3.Tocleanthefrontcover,eitherwipeitwith
adamp,lintfreeclothorwashitwithwarm
soapywater.Thoroughlydrythefrontcover
andret.
4.Donotimmersethefaninwaterorother
liquidstocleananyotherpartsofthefan.
5.Donotusestrongdetergents,solventsor
chemicalcleaners
6.Allowfantodrythoroughlybeforeuse.
7.Apartfromcleaning,noothermaintenanceis
required.
Disposal
Thisproductshouldnotbedisposed
ofwithhouseholdwaste.
Pleaserecyclewherefacilitiesexist.
Checkwithyourlocalauthorityfor
recyclingadvice.
Guarantee
UK only
We,RedringXpelairGroupLimited,providea
guaranteeagainstfaultypartsandmanufacture
foraperiodof2yearsfromthedateof
purchase.Intheunlikelyeventofaproduct
breakdownduringtheguaranteeperiodthe
productshouldbereturnedtotheplaceof
purchaseortoRedringXpelairGroupLimited.
Exclusions
• Thisguaranteedoesnotcovercompensation
forthelossoftheproductorconsequential
lossofanykind.
• Damageordefectstotheproductarising
fromincorrectinstallationorlackof
maintenance.
• Transportationcosts.
This guarantee does not affect your
statutory rights
Technical advice
and service
Customers outside UK -
see international below.
United Kingdom
Xpelairhaveacomprehensiverangeofservices
including:
• Freetechnicaladvicehelp-deskfrom
Engineersonallaspectsofventilation.
• Freedesignservice,quotationsandsite
surveys.
• Serviceandmaintenancecontractstosuitall
requirements.
Pleaseaskfordetails:
• BytelephoneonTechline:
+44(0)8443727766
• ByfaxonTechfax:+44(0)8443727767
• Attheaddressbelow
Head Office, UK Sales Office and Spares
RedringXpelairGroupLtd,
NewcombeHouse,NewcombeWay,
OrtonSouthgate,Peterborough,
PE26SEEngland
Telephone:+44(0)8443727761
Fax:+44(0)8443727762
Sales/SparesHotline:+44(0)8443727750
Sales/SparesFaxline:+44(0)8443727760
www.xpelair.co.uk
International.
• Guarantee:Contactyourlocaldistributoror
Xpelairdirectfordetails.
• TechnicalAdviceandService:Contactyour
localXpelairdistributor.
PartNo:26098AA(RevisionA)
Head Office, UK Sales Office and Spares
RedringXpelairGroupLtd,
NewcombeHouse,NewcombeWay,
OrtonSouthgate,Peterborough,
PE26SEEngland
Telephone:+44(0)8443727761
www.xpelair.co.uk
www.xpelair.co.uk/international
FM02118 ISO 9001: 2000
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11