Xpelair Simply Silent
DX100B
I
nstallation and Maintenance Instructions
English
ُ
ِ
َ َ
Doreadtheentireinstructionleaetbeforecommencinginstallation.
Doinstalleachfanwithameansfordisconnectioninallpolesinthexedwiring.
Domakesurethemainssupplyisswitchedobeforeattemptingtomakeelectrical
connectionsorcarryoutanymaintenanceorcleaning.
Pleaseleavethisleaetwiththefanforthebenetoftheuser.
Installation and Maintenance Instructions
English
Standard Timer Humidistat,Timer
Humidistat,Pull
Cord,Timer PullCord
DX100BR
(92997AW)
DX100BS
(93017AW)
DX100BTR
(92998AW)
DX100BTS
(93018AW)
DX100BHTR
(92999AW)
DX100BHTS
(93019AW)
DX100BHPTR
(93000AW)
DX100BHPTS
(93020AW)
DX100BPR
(93001AW)
DX100BPS
(93002AW)
Thisapplianceisintendedfor
connectiontoxedwiring.Checkthat
theelectricalratingshownoneach
fanmatchesthemainssupply.
THE APPLIANCE IS DOUBLE INSULATED
AND DOES NOT REQUIRE AN EARTH
CONNECTION.
Allinstallationsmustbesupervisedbya
qualiedelectrician.Installationsandwiringmust
conformtocurrentIEERegulations(UK),localor
appropriateregulations(othercountries).
This appliance can be used
by children aged from 8 years
and above and persons with
reduced physical, sensory
capabilities or lack of
experience and knowledge
if they have been given
supervision or instruction
concerning the use of the
appliance in a safe way and
understand the hazards
involved. Children shall not
play with the appliance.
Cleaning and maintenance
of the appliance shall not be
made by children.
AllXpelairSimplySilent™DX100BAC
fanshavethefollowingfeatures:
Twospeedextraction
(Selectableatinstallation)
DX100BR/DX100BS - Operatethefanusingan
on/oswitch(notsupplied).
DX100BTR/DX100BTS* - Built-intimer
operatesfanforapresetdelayfrom30
secondsto30minutes.
DX100BHTR/DX100BHTS* - Operateswhen
triggeredautomaticallybytheintegralhumiditysensor,
orbyusinganexternalon/oswitch(notsupplied).
In automatic mode: thebuilt-intimerautomatically
operatesthefanforapre-setdelaytimefrom30
secondsto30minutesoncehumiditydropsbelow
thepre-setRelativeHumidity(RH)value.
External operation:Whenswitchedousingthe
externalon/oswitchthefancontinuestorunfor
thepresetdelayfrom30secondsto30minutes.
DX100BHPTR/DX100BHPTS* - Operateswhen
triggeredautomaticallybytheintegralhumidity
sensor,byusinganexternalon/oswitch(not
supplied),orbyusingtheintegralpullcordswitch.
In automatic mode: Thebuiltintimerautomatically
operatesthefanforthepre-setdelaytimefrom30
secondsto30minutesoncehumiditydropsbelow
thepre-setRelativeHumidity(RH)value.
External operation:Whenswitchedousing
eithertheexternalon/oswitchortheintegral
pullcordswitchthefancontinuestorunforthe
pre-setdelayfrom30secondsto30minutes.
DX100BPR/DX100BPS - Operatethefanusing
anintegralpull-cord.
* Factory settings: Timer 15 minutes, RH 75%
Where to locate the fan.
Locateitashighaspossible.
Atleast110mmfromtheedgesof
themountingsurfacetothecentre
ofthehole.
Asfarawayaspossiblefromandoppositeto
themainsourceofairreplacementtoensure
airowacrosstheroom(e.g.oppositethe
internaldoorway).
Nearthesourceofsteamorodours.
• Notwhereambienttemperatures
are likely to exceed 50°C.
Ifinstalledinakitchen
fans must not be mounted
immediately above a cooker
hob, or eye level grill.
• Ifinstallinginaroomcontainingafuel
burning device which has a non-balanced
flue, it is the installer’s responsibility to
ensure that there is enough replacement air
to prevent fumes being drawn down the flue
when the fan is operating up to maximum
extract. Refer to Building Regulations for
specific requirements.
• Exhaustairmustnotbedischargedinto
a flue used for exhausting of fumes from
appliances supplied with energy other than
electric. Requirements of all authorities
concerned must be observed for exhaust air
discharge and intake flow rates.
• Notsuitableforuseinpossiblechemical
corrosive atmospheres.
Installation
What the installer will need.
3mmelectrician’sscrewdriver
andNo.1or2Pozidrive
screwdrivers.
English
Overall Dimensions (mm)
Back plate
fixing positions
A
Front Cover Removal
B
DEPRESSCOVERLATCHWITHTOOL&REMOVECOVERCOMPLETE
English
IMPORTANT – PLEASE READ
Adjusting the humidity setting
Adjusting the run on timer setting
Fanswitcheson
atlowerlevelof
condensation
(anti-clockwise)
MORESENTITIVE
(RH=50%)
Fanrunsonfora
shortertimewhen
theexternalswitch
isturnedo
Fandoesnot
switchonuntil
higherlevelof
condensation
(clockwise)
LESSSENTITIVE
(RH=95%)
Fanrunsonfora
longertimewhen
theexternalswitch
isturnedo
Factory settings:
Timer15minutes,RH75%
Maximum30minutesMinimum30seconds
C
English
Wiring and setting up
D1
DX100BR / DX100BS
DX11BPR / DX100BPS
DX100BTR / DX100BTS
SEEDETAILB
SEEDETAILC
CUSTOMER
CONNECTION
TERMINAL
DETAIL C
SCALE 2.000
OVER-RUN
TIMER
DETAIL B
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
HIGH
SPEED
LOW
SPEED
SEEDETAILA
CUSTOMER
CONNECTION
TERMINAL
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
DETAIL A
SCALE 2.000
HIGH
SPEED
LOW
SPEED
LEVELLINE
LEVELLINE
English
Wiring and setting up
D2
DX100BHTR / DX100BHTS
DX100BHPTR / DX100BHPTS
SEEDETAILF
SEEDETAILG
CUSTOMER
CONNECTION
TERMINAL
SEEDETAILD
SEEDETAILE
CUSTOMER
CONNECTION
TERMINAL
DETAIL F
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
HIGH
SPEED
LOW
SPEED
DETAIL D
SCALE 2.000
OVER-RUN
TIMER
HUMIDISTAT
DETAIL E
SCALE 2.000
SETJUMPERTOREQUIRED
POSITIONFORSPEEDSETTING
HIGH
SPEED
LOW
SPEED
DETAIL G
SCALE 2.000
OVER-RUN
TIMER
HUMIDISTAT
LEVELLINE
LEVELLINE
English
If wall mounting the fan, you will also need:
• A100mmdiameterpreparedhole.
• ASimplySilentWallKit:
SSWKWR(92991AW)–Round/White
SSWKWS(92992AW)–Square/White
SSWKBR(92993AB)–Round/Brown
SSWKBS(92994AB)–Square/Brown
If ceiling mounting the fan, you will also need:
• A100mmdiameterpreparedhole.
• A100mmdiameterpreparedholeforthe
externalgrille(notsupplied),ideallypositioned
toallowcondensationtorunawayfromtherst
bendintheduct,towardstheexternalgrille.
• Appropriateancillariesfortermination.These
itemsareavailablefromXpelair:
1.3mexibleductingRef:89663AA.If
theductpassesthroughacoldspaceuse
insulatedductref:89847AA.
2.SotGrilleRef:89742AW.
If window mounting the fan, you will also need:
• SSWIN–SimplySilentWindowKit.
Ref:92996AA
Installing the isolating switch
and cables.
Ameansfordisconnectioninallpoles
mustbeincorporatedinthexedwiring
inaccordancewithwiringregulations
• Ifmetalswitchboxesareused,earthing
regulations must be followed.
• Thecross-sectionalareaofthesupplycord
usedshouldberangedfrom1-1.5mm².
• DX100BR/DX100BS/DX100BPR/
DX100BPS–2core.
• DX100BTR/DX100BTS/DX100BHTR*
/DX100BHTS*/DX100BHPTR*/
DX100BHPTS*–3core.
*Ifwiringtoremoteswitch.
1. Check that the electrical rating shown inside
the back-plate matches your mains supply.
2. Check there are no buried pipes or cables
e.g. electricity, gas, water behind the switch
location (in the wall or above the ceiling). If in
doubt, seek professional advice.
3. Isolate the mains supply.
4.Layinthecablefromtheisolatingswitchtothe
fanlocationviatheon/oswitch(ifrequired).
5.Layinthecablefromtheisolatingswitchto
thepointofconnectiontothemainssupply.
Warning: Do not make any
connections to the electrical supply
at this stage.
6.Installtheisolatingswitchandon/oswitch
(ifrequired).
7.Makeallconnectionswithintheisolating
switchandtheon/oswitch(ifrequired).
Wet Rooms: On/Off switch must
be situated so that it cannot be
touched by persons making use of
the bath or shower.
For Australia Only – DX100BR / DX100BS /
DX100BPR / DX100BPS Connectiontothe
supplycanbemadebyaexible2-corecable
completewith3pinplugforinsertionintoan
approved10AGPOordirectlywiredthroughan
approved10Awallmountedsurfaceswitchwith
atleast3mmclearancebetweencontacts.
For Australia Only –DX100BTR / DX100BTS /
DX100BHTR / DX100BHTS / DX100BHPTR /
DX100BHPTS Thesemodelsarepermanently
connectedtothesupplyandoperationis
controlledbyaremoteswitch.Theyshould
bedirectlywiredtothesupplythroughan
approved10Awallmountedsurfaceswitch
withatleast3mmclearancebetweencontacts.
Preparing the Fan for installation.
1. Removethefrontcoverbydepressingthe
latchontheundersideofthecoverand
pullingothefrontcoverfromthebottom
(SeeFigureB).
If working above ground floor
level, safety precautions must be
observed.
Mark the position of the back-plate
2. Holdtheback-platesothatthelevelline
markedonitisorientatedhorizontally.
3. Carefullyinsertthefantubeintothewallduct.
4. Markonthewallthepositionsofthexing
holesintheback-plate.
5. Removethebackplatefromtheducting.
6. Drillscrewholesinthesepositionsifnecessary,
andtwallplugsandscrewsasrequired.
If installing in a ceiling, appropriate
termination ancillaries are required.
Follow instructions provided.
Mount the back-plate.
7. Feedthemainscablethroughthecable
entryholeinthebackplatetotheterminals.
8. Insertthefantubeoftheback-plateintothe
wallduct/ceilingasbefore.
9. Fastentheback-platetothewall/ceiling
usingappropriatefasteners.SeegureA.
10.Ifusingscrews,donotovertighten.
Wire the electrical connections.
11.Makesurethemainssupplyisisolated.
Switchothemainselectricalsupplyand
removefuses.
12.Feedthecabletotheterminalblock.Wire
thefanasshowninFigureEusingthe
diagramappropriatetothefanmodel.
13.Connectthecablefromtheisolatingswitch
totheelectricalsupplywiring.
Fan Settings
SPEED SETTING
Thefansarefactorysettolowspeed,buthave
twospeedsettingsfordierentapplications.
Selecteitherhighorlowspeedbyconnecting
thejumperbetweenthecentreandhighorlow
speedpinonthejumper(seeFigureD1&D2).
DX100BTR / DX100BTS Only.
• Toadjusttheover-runperiodturnthecontrol
(T)clockwisetoincreaseandanti-clockwise
todecrease–seeFigureD1.
DX100BHTR / DX100BHTS / DX100BHPTR /
DX100BHPTS only – see figures C and D.
• Thepre-sethumidityoperationisfactoryset
atapproximately75%RelativeHumidity(RH),
butcanbeadjustedbetween65%and85%
RHbycontrolH.
• Theover-runtimerisfactorysetat15minutes
butcanbeadjustedfrom30secondsto30
minutesbycontrolT.
• TurnthecontrolsclockwisetoincreaseRHor
timeandanti-clockwisetodecrease.
English
DX100BR/DX100BS
DX100BPR/DX100BPS
DX100BTR/DX100BTS
DX100BHTR/DX100BHTS
DX100BHPTR/DX100BHPTS
E
FAN
TERMINALS
FAN
TERMINALS
FAN
TERMINALS
DOUBLEPOLE
ISOLATINGSWITCH
DOUBLEPOLE
ISOLATINGSWITCH
DOUBLEPOLE
ISOLATINGSWITCH
ON/OFF
SWITCH
(OPTIONAL)
ON/OFF
SWITCH
(REQUIRED)
LAMP
(IFREQUIRED)
LAMP
(IFREQUIRED)
FUSE
FUSE
FUSE
For fixed wiring circuits the protective fuse
for the appliance must not exceed 5A.
English
Using the fan
DX100BR / DX100BS Only
• Operatethefanusingtheon/oswitch(not
supplied).Repeattoswitcho.
DX100BTR / DX100BTS Only
• Operatethefanusinganon/oswitch(not
supplied).Note–thefanmaytakeupto10
secondstoturnononcetheswitchhasbeen
operated.Whentheswitchisturnedo,
thefancontinuestooperateforthesettime
delay.Toadjusttheover-runperiod,turnthe
control“T”clockwisetoincreaseandanti-
clockwisetodecrease–seeFigureD1.
DX100BHTR / DX100BHTS Only
• Automatic mode-Thefanautomatically
adjuststoslowchangesinnaturalhumidity
levelswithoutoperatingthefan.Ifthehumidity
levelsincreaseatarateslowerthan5%RH
in5minutes,uptothepre-sethumiditylevel,
thefanwillnotbetriggeredbyhumidity.This
istopreventnuisancetriggeringofthefan.If
humiditylevelsincreasequickerthan5%RH
in5minutesthefanwilloperate.Whenrelative
humiditydropsthefancontinuestooperatefor
theadjustabletimedelay.
• External operation-Usetheexternalon/o
switch.Whenthefanisswitchedo,thefan
continuestooperatefortheadjustabletime
delaythengoesintoautomaticmode.
DX100BHPTR / DX100BHPTS Only
• Automatic mode-Thefanautomatically
adjuststoslowchangesinnaturalhumidity
levelswithoutoperatingthefan.Ifthehumidity
levelsincreaseatarateslowerthan5%RH
in5minutes,uptothepre-sethumiditylevel,
thefanwillnotbetriggeredbyhumidity.This
istopreventnuisancetriggeringofthefan.If
humiditylevelsincreasequickerthan5%RH
in5minutesthefanwilloperate.Whenrelative
humiditydropsthefancontinuestooperatefor
theadjustabletimedelay.
• External operation-Usetheexternalon/o
switch.Whenthefanisswitchedo,thefan
continuestooperatefortheadjustabletime
delaythengoesintoautomaticmode.
• Pull Cord operation–Usetheintegralpull
cordswitch.Whenthefanisswitchedo,the
fancontinuestooperatefortheadjustable
timedelaythengoesintoautomaticmode.
DX100BPR / DX100BPS Only
• Operatethefanbypullingandreleasingthe
cord.Repeattoswitcho.
All Fans
Re-tthefrontcoverbyhookinginthetoprst,
andthenswingthecoverdowntoclipintoplace.
Cleaning
(recommendedonceamonth)
1.Beforecleaning,isolatethefancompletely
fromthemainssupply.
2.Removethefrontcoverbydepressingthe
latchontheundersideofthecoverand
pullingothefrontcoverfromthebottom.
3.Tocleanthefrontcover,eitherwipeitwith
adamp,lintfreeclothorwashitwithwarm
soapywater.Thoroughlydrythefrontcover
andret.
4.Donotimmersethefaninwaterorother
liquidstocleananyotherpartsofthefan.
5.Donotusestrongdetergents,solventsor
chemicalcleaners
6.Allowfantodrythoroughlybeforeuse.
7.Apartfromcleaning,noothermaintenanceis
required.
Disposal
Thisproductshouldnotbedisposed
ofwithhouseholdwaste.
Pleaserecyclewherefacilitiesexist.
Checkwithyourlocalauthorityfor
recyclingadvice.
Guarantee
UK only
We,RedringXpelairGroupLimited,providea
guaranteeagainstfaultypartsandmanufacture
foraperiodof2yearsfromthedateof
purchase.Intheunlikelyeventofaproduct
breakdownduringtheguaranteeperiodthe
productshouldbereturnedtotheplaceof
purchaseortoRedringXpelairGroupLimited.
Exclusions
• Thisguaranteedoesnotcovercompensation
forthelossoftheproductorconsequential
lossofanykind.
• Damageordefectstotheproductarisingfrom
incorrectinstallationorlackofmaintenance.
• Transportationcosts.
This guarantee does not affect your
statutory rights
English
Technical advice
and service
Customers outside UK -
see international below.
United Kingdom
Xpelairhaveacomprehensiverangeofservices
including:
• Freetechnicaladvicehelp-deskfrom
Engineersonallaspectsofventilation.
• Freedesignservice,quotationsandsite
surveys.
• Serviceandmaintenancecontractstosuitall
requirements.
Pleaseaskfordetails:
• BytelephoneonTechline:
+44(0)8443727766
• ByfaxonTechfax:+44(0)8443727767
• Attheaddressbelow
Head Office, UK Sales Office and Spares
RedringXpelairGroupLtd,
NewcombeHouse,NewcombeWay,
OrtonSouthgate,Peterborough,
PE26SEEngland
Telephone:+44(0)8443727761
Fax:+44(0)8443727762
Sales/SparesHotline:+44(0)8443727750
Sales/SparesFaxline:+44(0)8443727760
www.xpelair.co.uk
International.
• Guarantee:Contactyourlocaldistributoror
Xpelairdirectfordetails.
• TechnicalAdviceandService:Contactyour
localXpelairdistributor.
PartNo:26097AA(RevisionA)
Head Offi ce, UK Sales Offi ce and Spares
RedringXpelairGroupLtd,
NewcombeHouse,NewcombeWay,
OrtonSouthgate,Peterborough,
PE26SEEngland
Telephone:+44(0)8443727761
www.xpelair.co.uk
www.xpelair.co.uk/international
FM02118 ISO 9001: 2000
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Xpelair DX100B Installation And Maintenance Instructions Manual

Category
Household fans
Type
Installation And Maintenance Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI