1
1
Pin1=NC
Pin2=GND
Pin3=NC
Pin4=CANH
Pin5=CANL
Pin6=NC
Pin7=NC
Pin8=NC
Pin1Pin8
Pin1=TX_RS485A
Pin2=TX_RS485B
Pin3=NC
Pin4=GND
Pin5=NC
Pin6=NC
Pin7=NC
Pin8=NC
Pin1Pin8
4
IX.CommunicationsetupVIII.Smartmeterconnection
Notice
XI.EUDeclarationofConformity
X.Commissioning XII.Contact
6
5
▪Theconnectionrefersto“ GPRS/WiFi-stickUserManual”.
▪Checkthattheinverterisgroundedreliably.
▪Checkthattheventilationconditionsurroundingtheinverterisgood.
▪Checkthatthegridvoltageatthepointofconnectionoftheinverteriswithinthe
permittedrange.
▪CheckthatthesealingplugsinDCconnectorsandcommunicationcableglandsare
sealedtightly.
▪Checkthatgrid/batteryconnectionregulationsandotherparametersettingsmeet
safetyrequirements.
▪CheckthecorrectcommunicationconnectionbetweenthebatteryBMSandtheinverter.
▪Checkthecorrectcommunicationconnectionbetweenthesmartmeterandtheinverter.
1.SwitchonACcircuitbreakerbetweentheinverterandthegrid.
2.SwitchonDCswitch.
3.Switchonbattery.
4.LinktoinverterWiFi.
5.Setthecommunicationparametersofthesmartmeter.
6.SetparametersthroughApp(Safety,Smartmeter,Battery,Working-mode).
7. Clickpower-onbuttonthroughApp,Energystorageinverterwillstarttowork.
WithinthescopeoftheEUdirectives:
-Electromagneticcompatibility2014/30/EU(L96/79-106,March29,2014)(EMC)
-Lowvoltagedirective2014/35/EU(L96/357-374,March29,2014)(LVD)
-Radioequipmentdirective2014/53/EU(L153/62-106,May22,2014)(RED)
AISWEITechnology(Shanghai)Co.,Ltd.confirmsherewiththattheinverters
mentionedinthisdocumentareincompliancewiththefundamentalrequirementsand
otherrelevantprovisionsoftheabovementioneddirectives.
TheentireEUDeclarationofConformitycanbefoundatwww.aiswei-tech.com.
Ifyouhaveanytechnicalproblemswithourproducts,pleasecontactourservice.
Werequirethefollowinginformationinordertoprovideyouwiththenecessaryassistance:
-Inverterdevicetype
-Inverterserialnumber
-Batterytype
-TypeandnumberofconnectedPVmodules
-Errorcode
-Mountinglocation
-Warrantycard
EMEA
Serviceemail:service.EMEA@solplant.net
APAC
Serviceemail:service.APAC@solplanet.net
LATAM
Serviceemail:service.LATAM@solplanet.net
AisweiGreaterChina
Serviceemail:service.china@aiswei-tech.com
Hotline:+864008019996
Taiwan
Serviceemail:service.taiwan@aiswei-tech.com
Hotline:+886809089212
https://solplanet.net/contact-us/
▪Foroutdooruse,thecommunicationcablesmustbeUV-resistant.
▪MakesureACcableistotallyisolatedfromACpowerbeforeconnecting.
DANGER
Connectiondiagram
N
L
Grid 12
3 4
L
N
11
22
3
4
5
6
6
5
RS485A
RS485B
PH00.7Nm
1.Smartmetercommunication
2.ACcableconnection
N
L
Grid
12L
N
34
PH21.6Nm
6
5
▪Separatecommunicationcablesfrompowercablesandseriousinterferencesources.
▪ThecommunicationcablesmustbeCAT-5Eorhigher-levelshieldcables.Pin
assignmentcomplieswithEIA/TIA568Bstandard.Foroutdooruse,thecommunication
cablesmustbeUV-resistant.Thetotallengthofcommunicationcablecannotexceed
1000m.
DANGER
1.BMScommunication
22
3
456
2.WiFi
22
3
1