ASW1000S

solplanet ASW1000S Installation guide

  • Hello! I'm your chat assistant, and I've reviewed the Solplanet Quick Installation Guide for the ASW1000S-S, ASW1500S-S, ASW2000S-S, and ASW3000S-S inverters. This guide provides instructions on safe installation, mounting, electrical connections, and communication setup for these devices. I'm ready to answer any questions you might have about the contents of the document or the inverters themselves.
  • What type of PV modules can be connected to this inverter?
    What is the recommended mounting temperature for the inverter?
    What should I do before making any electrical connections?
    What is the recommended length for the PE conductor?
QuickInstallationGuide
Model:ASW1000S/1500S/2000S/3000S-S
Language:English
I.SafetyInstruction
1.Thecontentsofthisdocumentwillbeupdatedirregularlyforproductversionupgradeorother
reasons.Unlessotherwisespecified,thisdocumentonlyworksasguide.Allstatements,
informationandsuggestionsinthisdocumentdonotconstituteanyguarantee.
2.Thisproductcanonlybeinstalled,commissioned,operatedandmaintainedbytechnicianswho
havecarefullyreadandfullyunderstoodtheusermanual.
3.ThisproductmustonlybeconnectedwithPVmodulesofprotectionclassII(inaccordancewith
IEC61730,applicationclassA).PVmoduleswithahighcapacitancetogroundmustonlybeused
iftheircapacitydoesnotexceed1μF.DonotconnectanysourcesofenergyotherthanPV
modulestotheproduct.
4.Whenexposedtosunlight,thePVmodulesgeneratedangeroushighDCvoltagewhichispresent
intheDCcableconductorsandlivecomponents.TouchingliveDCcableconductorsandthelive
componentsresultinlethalinjuriesduetoelectricshock.
5.Allcomponentsmustremainwithintheirpermittedoperatingrangesatalltimes.
6.TheproductcomplieswithElectromagneticcompatibility2014/30/EU,LowVoltageDirective
2014/35/EUandRadioEquipmentDirective2014/53/EU.
II.Mountingenvironment
III.Scopeofdelivery
Inverterx1 DCconnectorx1
Documentationx1
IV.Invertersmounting
V.ACconnection
DANGER
1
3
2
VI.DCconnection
VII.Communicationsetup
Wallmountingbracketx1
1.Ensurethattheinverterisinstalledoutofthereachofchildren.
2.Toensurebestoperatingstatusandprolongedservicelife,themounting
ambienttemperatureoftheinvertershouldbe≤40°C.
3.Toavoiddirectsunlight,rain,snow,pondingontheinverter,itis
suggestedtomounttheinverterinplaceswithatopprotectiveroof.
Donotcompletelycoverthetopoftheinverter.
4.Themountingconditionmustbesuitablefortheweightandsizeoftheinverter.Theinverteris
suitabletobemountedonsolidwallthatisverticalortiltedbackwards(Max.15°).
Itisnotrecommendedtoinstalltheinverteronwallmadeofplasterboardsorsimilarmaterials.
Theinvertermaymakenoisewhenworking.
5.Toensureadequateheatdissipation,theclearancesbetweenthe
inverterandotherobjectsarerecommendedasfollows:
Smartmeterterminalx1
ACconnectorx1
Screwaccessoryx1
Magneticringx1(optional) GPRS/WiFistickx1(optional)
Communicationcoverx1(optional)
3.Inserttheadaptertothesocketelement,stuffthesealringintotheadapterandtightenthe
swivelnut.
1.UseaΦ10mmbittodrill3holesatadepthof
about70mmaccordingtothelocationofthe
wallmountingbracket.
▪Allelectricalinstallationsmustbedoneinaccordancewithalllocalandnationalrules.
▪MakesurethatallDCswitchesandACcircuitbreakershavebeendisconnectedbefore
establishingelectricalconnection.Otherwise,thehighvoltagewithintheinverter
mayleadtoelectricalshock.
▪Inaccordancewithsafetyregulations,theinverterneedbegroundedfirmly.When
poorgroundconnection(PE)occurs,theinverterwillreportPEgroundingerror.Please
checkandensurethattheinverterisgroundedfirmlyorcontactAISWEIservice.
1.ACcablerequirementsareasfollows.Inserttheconductorintoasuitableferruleacc.to
DIN46228-4andcrimpthecontact.
2.LoosentheswivelnutofACconnector.Insertthecrimpedconductorsintocorresponding
terminalsandtightenscrewswiththeaccompaniedAllenkey.Torque:2.0Nm
DANGER
Separatecommunicationcablesfrompowercablesandseriousinterferencesources.
ThecommunicationcablesmustbeCAT-5Eorhigher-levelshieldcables.Pin
assignmentcomplieswithEIA/TIA568Bstandard.Foroutdooruse,thecommunica-
tioncablesmustbeUV-resistant.Thetotallengthofcommunicationcablecannot
exceed1000m.
Ifonlyonecommunicationcableisconnected,insertasealingplugintotheunused
holeofsealingringofthecablegland.
Beforeconnectingcommunicationcables,ensuretheprotectivefilmorcommunica-
tionplateattachedtothecommunicationopeningontheinverterissealedtightly.
DANGER
MakesurePVmoduleshavegoodinsulationagainstground.
▪Onthecoldestdaybasedonstatisticalrecords,theMax.open-circuitvoltageofthe
PVmodulesmustnotexceedtheMax.inputvoltageoftheinverter.
CheckthepolarityofDCcables.
EnsurethatDCswitchhasbeendisconnected.
DonotdisconnectDCconnectorsunderload.
1.Pleasereferto DCConnectorInstallationGuide.
2.BeforeDCconnection,inserttheDCplugconnectorswith
sealingplugsintoDCinputconnectorsoftheinverterto
ensureprotectiondegree.
2.Insertwallplugsintothewallandfixthewall
mountingbrackettothewallbyscrewing
threeself-tappingscrews(SW10).
3.Hangtheinvertertothewallmounting
bracket.
4.Securetheinvertertothewallmounting
bracketusingM4screw.
Screwdrivertype:PH2,torque:1.6Nm.
4.PlugtheACconnectorintothesocketfortheACconnection.
5.Ifrequired,youcanconnectasecondprotectiveconductorasequipotentialbonding.
Object Description Value
AExternaldiameter
BCopperconductorcross-section
C
D
Strippinglengthoftheinsulatedconductors
Strippinglengthofthecableoutersheath
9-14mm
2.5-6mm 2
13mm
53mm
ThePEconductormustbe2mmlongerthantheLandNconductors.
A
C
D
B
PE
1
2
3
1
2
Customerprovidedtype:M4
Groundingcable Copperconductorcross-section:2.5-6mm
Object Explanation
OTterminallug
M4×10screw Screwdrivertype:PH2,torque:1.6Nm
2
IP65
4K4H
26 4
32 0
94
mm
300
30 0
500
500
500
129 129
296
312
55.3
320
20.5
φ9x212xφ9
208.3
66.5
1
2
Pin1=TX_RS485A
Pin2=TX_RS485B
Pin3=NC
Pin4=GND
Pin5=GND
Pin6=NC
Pin7=+7V
Pin8=+7V
Pin1Pin8
4
1.COM1:RS485(optional)
2.COM2:GPRS/WiFi
PIN1 PIN2 PIN3 PIN4
VCC
PIN
Assignment RS485A RS485B
GND
VIII.Commissioning
Notice
IX.EUDeclarationofConformity
X.TechnicalData XI.Contact
6
P/N:540-30113-03
Date:2022-07-21
5
3.Smartmeter
1500W
580V
80-550V
12A
12A
1/1
18A
1000W
5A
0.8ind...0.8cap
<3%
320×264×94mm
6.5kg
<25dB(A)@1m
Plug-inDCconnector
GPRS/WiFi,RS485(Optional)
Convection
-25...+60
0...100%
4000m(Deratingabove3000m)
IP65
4K4H
Transformerless
Wallmounting
LED
Plug-inACconnector
ASW1000S-S ASW1500S-S ASW2000S-S ASW3000S-S
DCInput
Max.PVmodulespower(STC)
Max.DCinputvoltage
MPPvoltagerange
Max.DCinputcurrent
Max.DCinputcurrent,perMPPT
NumberofMPPT/stringsperMPPT
Max.DCinputshortcurrent
ACOutput
Ratedactivepower
Max.apparentpower
Ratedgridvoltage
Ratedgridfrequency
Max.ACoutputcurrent
Adjustabledisplacementpowerfactor
Harmonicdistortion(THD)atPac.r
GeneralData
Dimensions(WxHxD)
Weight
Noiseemission(typical)
DCconnection
Communication
Cooling
Operatingtemperaturerange
Relativehumidity(non-condensing)
Max.operatingaltitude
Degreeofprotection
ClimateCategory
Topology
Mounting
Display
ACconnection
TechnicalData
1000VA
220/230V
50/60Hz
2250W 3000W 4500W
1500W
1500VA
2000W
2000VA
3000W
3000VA
7.5A 10A 13.6A
1)RS485cablepinassignmentasbelow.
2)Loosentheswivelnutofthecableglandonthe
communicationcover,removesealingplugs
andleadthecablethroughtheswivelnut,sealing
ring,communicationcoverandmagneticring.
3)Insertthecableintothesocket,attachthe
communicationcovertoinverterwithM4
screws,andtightentheswivelnut.
Screwdrivertype:PH2,torque:1.6Nm
Theconnectionrefersto GPRS/WiFi-stickUserManual.
1)Removethecommunicationplatefrom
theinverter.
2)Loosentheswivelnutofthecablegland
onthecommunicationplate,removethe
sealingplugandleadthestrippedcable
throughthecableglandandcommunication
plate,pressthelatchofthesmartmeter
terminalandinsertthestrippedcable
accordingly.Makesurethecableis
connectedfirmly.
3)Insertthesmartmeterterminaltothesocket,
attachcommunicationplatetotheinverter
withM4screws,andtightentheswivelnut.
Screwdrivertype:PH2,torque:1.6Nm.
Checkthattheinverterisgroundedreliably.
Checkthattheventilationconditionsurroundingtheinverterisgood.
Checkthatthegridvoltageatthepointofconnectionoftheinverteriswithinthe
permittedrange.
CheckthatthesealingplugsinDCconnectorsandthecommunicationcablegland
aresealedtightly.
Checkthatgridconnectionregulationsandotherparametersettingsmeetsafety
requirements.
1.SwitchonACcircuitbreakerbetweentheinverterandthegrid.
2.SwitchonDCswitch.
3.WhenthereissufficientDCpowerappliedandthegridconditionsaremet,theinverterwill
starttooperateautomatically.
WithinthescopeoftheEUdirectives:
-Electromagneticcompatibility2014/30/EU(L96/79-106March29,2014)(EMC)
-Lowvoltagedirective2014/35/EU(L96/357-374March29,2014)(LVD)
-Radioequipmentdirective2014/53/EU(L153/62-106May22,2014)(RED)
AISWEITechnology(Shanghai)Co.,Ltd.confirmsherewiththattheinverters
mentionedinthisdocumentareincompliancewiththefundamentalrequirementsand
otherrelevantprovisionsoftheabovementioneddirectives.
TheentireEUDeclarationofConformitycanbefoundatwww.aiswei-tech.com.
1
2
3
4
1
2
3
2
1
1
2
3
4
1
2
3
4)Ifcommunicationcoverused,removeonlyone
sealingplugofthecableglandtothreadthe
cable.Detailedinstallationprocessfollows
abovesteps.
Ifyouhaveanytechnicalproblemswithourproducts,pleasecontactourservice.
Werequirethefollowinginformationinordertoprovideyouwiththenecessaryassistance:
-Inverterdevicetype
-Inverterserialnumber
-TypeandnumberofconnectedPVmodules
-Errorcode
-Mountinglocation
-Warrantycard
ScanQRcode:
MonitoringAPP
EMEA
Serviceemail:service.EMEA@solplanet.net
APAC
Serviceemail:service.APAC@solplanet.net
LATAM
Serviceemail:service.LATAM@solplanet.net
AisweiGreaterChina
Serviceemail:service.china@aiswei-tech.com
Hotline:+864008019996
Taiwan
Serviceemail:service.taiwan@aiswei-tech.com
Hotline:+886809089212
https://solplanet.net/contact-us/
/