Skov Distribution Shutter DOL 9940/DOL 99B Technical User Guide

Type
Technical User Guide
2019.05.10 • 604176
Distribution shutter
Distribution shutter Technical User Guide
EN
Distribution shutter
Product and Documentation Changes
We reserve the right to change this document and the product herein described without further notice. In case of doubt,
please contact us.
Date of change appears from the front and back of this manual.
Note
All rights reserved the company. No part of this manual may be reproduced in any manner whatsoever
without the express written permission from the company.
All reasonable efforts has been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, we would appreciate being notified
thereof.
Irrespective of the above, shall not accept any liability with regard to loss or damage caused or alleged to be
caused by reliance on any information contained herein.
Copyright 2015 by the company.
Technical User Guide 3
Distribution shutter
ENGLISH ................................................................................................................4
1 PRODUCT DESCRIPTION ......................................................................................... 4
2 Electric Connection .................................................................................................. 4
2.1 Motor on the Distribution Shutter ....................................................................................... 4
2.1.1 Jumper on winch motor 74CO printed circuit board ................................................................................. 4
2.1.2 Circuit Diagram for Distribution Shutter .................................................................................................... 5
3 Adjustment of the Distribution Shutter ................................................................... 6
4 TECHNICAL DATA .................................................................................................... 7
4.1 Dimensioned Sketches ........................................................................................................ 7
EN
4 Technical User Guide
Distribution shutter
ENGLISH
1 PRODUCT DESCRIPTION
This User Guide deals with the installation and connection of the distribution shutter.
Using a motordriven distibution shutter enables the feed weigher to deliver food to two feeding systems.
2 Electric Connection
Installation, service and troubleshooting of electrical equipment must be carried out by expert
staff in compliance with applicable national regulations – in Europe, this would be EN 60204-1
or other current EU regulations.
A supply separator must be installed for each motor and power supply to facilitate voltage-free
work on the electrical equipment. Supply separators are not supplied by the company.
2.1 Motor on the Distribution Shutter
2.1.1 Jumper on winch motor 74CO printed circuit board
Jumper setting on the PCB.
Figure 1: Jumper setting
74CO Normal
ON/OFF
Figure 2: Jumper.
EN
House 1
House 2
House 2
House 1
Feed Weigher
Feed Weigher
Technical User Guide 5
Distribution shutter
2.1.2 Circuit Diagram for Distribution Shutter
Connect the motor to the controller which has been set controlling.
Figure 3: Circuit Diagram
Ex. of terminal number For correct
connection see the setup menu
Show Installation
6 Technical User Guide
Distribution shutter
3 Adjustment of the Distribution Shutter
Adjust the distribution shutter as follows:
1. Loosen the two nuts on the axle between winch motor and the distribution shutter. See Figure 4.
2. Follow the instructions under Testing in the Technical Manual for the controller.
3. When the winch motor stops, turn the distribution shutter manually to the feeding system 1 position
(usually to the right). See Figure 5.
4. Tighten the two nuts again. See Figure 4.
Figure 4: Loosen two nuts on axle.
Figure 5: Turn shutter to the feeding system 1 position (usually to the right).
Checking adjustment:
1. Running time for turning from one extreme position to another must not exceed 90 sec.
2. The winch motor must reach the end stop when the distribution shutter is in its extreme positions.
3. Turn the distribution shutter by activation via the computer, as for adjustment of the distribution
shutter.
4. If the distribution shutter scrapes against the sides when turned, this will be because the distribution
shutter has been tightened askew; correct the tightening.
Technical User Guide 7
Distribution shutter
4 TECHNICAL DATA
Distribution shutter
Material
Aluzinc plate
Dimensions [mm]
H x W x D: 255 x 350 x 350
Weight, distribution shutter and winch
motor [kg]
10
Winch motor 74CO
Supply [V DC]
24 ± 20 %
Running time, unloaded [sec.]
70
Running time, at max. load [sec.]
90
Max. torque [Nm]
24
Max. power consumption [A]
0,1
Feedback signal
0-10 V - impedance 2.2 KΩ
Protection class, cabinet IP 65
4.1 Dimensioned Sketches
All measurements are indicated in mm.
Figure 6: Distribution shutter
SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev
Tel. +45 72 17 55 55 • Fax +45 72 17 59 59 • www.skov.com • E-mail: skov@skov.dk
2019.05.10 • 604176 14.00 • EN • Made in Denmark
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Skov Distribution Shutter DOL 9940/DOL 99B Technical User Guide

Type
Technical User Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI