Gianni Industries EB261/EB265/EB270 Installation guide

Type
Installation guide
260x30x48mm
100x46x1.5mm
EB265
EB265M
EB261
EB261M
(Monitored)
(Monitored)
12~24VAC/DC
±10%
1.2A/12VDC
-10~+45°C
0~95%
260x30x73mm
100x46x1.5mm
Fail-Secure series of Electric Dropbolt Locks are suitable for use on single
acting inswing or outswing doors.
Double Action Door Single Action Door
Reverse the latchbolt for right or left handed doors.
Humidity
Operating Voltage
Voltage Tolerance
Current Draw
Operating Temperature
Strike Plate
EB270
EB270M
(Monitored)
Inswing
* 62mm long cylinder for doors up to 42mm thick, 72mm long cylinder for doors up to 52mm thick.
Copyright © All rights reserved. P-MU-EB270 Published 2016.07.15
Outswing
Electric Dropbolt Installation Instructions
(Fail-Secure Series)
Door Preparation
EB270
EB265
Unit:mm Unit:mm
(EB270 shown)
Dimensions
Lock
EB261
Cut hole in the door for cylinderMortise door edge and drill holes according
to the template
Attach fixing lugs
Connect wiring to the lock
Insert the lock into
mortise cutout and
fasten screws to doors
Install cylinder cover Use 5x45mm Philip
flat head screw to
tighten the cylinder
EB265
EB261
EB265
EB261
Butt Splice (IDC) Connector
Copyright © All rights reserved. P-MU-EB270 Published 2016.07.15
EB270
EB270
Place the wire inside the connector
and use pliers to press down on the
head of the connector evenly.
1. The connection of an incorrect voltage may result
in damage and is not covered by the product
warranty.
Ø4
mm
Ø5 mm
Ø
4
mm
Ø
5 mm
35mm
55mm
2. Select the appropriate power supply cable to ensure
if the lock receives sufficient power to operate.
3. This product has been designed for use in weather
protected areas and normal circumstances, hence it
does not require any maintenance. DO NOT OIL OR
LUBRICATE.
4.This product must be used in conjunction with a
quality floor spring or door closer to ensure positive
realignment on closing.
Important
Make sure that the “+” and “-” wires are
connected correctly. Failure to observe polarity will
result in a short circuit. Damage caused by improper
connection will void warranty.
(EB261M/265M/270M)
Wiring Diagram
Warning
Application
Exit Button
N.C. (Fail-safe)/N.O.(Fail-secure) Switchable
PB
GND
12VDC
1A
12VDC
1.5A
N.C.
N.O.
Timer
0~45S
N.O.
COM.
PSM-25T
(or PSM-26T)
DG-175
EB261M
L
N
INPUT
100~240VAC
(Yellow) Locked
(Green) COM
(White) Unlocked
1
2 3
4 5 6
7
  • Page 1 1