Gianni Industries EB195TGVGL Installation guide

Type
Installation guide

This manual is also suitable for

Pull in: 0.9A/12V; 0.45A/24V
EB180
EB185
EB190TG
EB195TG
Holding: 0.15A/12V; 0.1A/24V
EB185 / EB195TGEB180/EB190TG
0
12
9
41
41
3
2
2
25
001
25
941
2
2
41
3
012
2
5
0
01
25
EB180/190 Series Electric Dropbolt Installation Instructions
Features Specifications
Horizontal or vertical installation
Energy saving design
Intelligent electronics
Vandal resistant circuit design
Relock time delay (Selectable from 0, 3, 6, 9 seconds)
Push button trigger input (For TG series)
Models
12/24 VDCOperating Voltage
Current Draw
Bolt Status Sensor Output
Door Position Status Output
Relock Time Delay
Push Button Trigger Input
Intelligent Electronics & Energy Saving Design
All models are designed with intelligent logic circuit allowing the bolt to
keep retracting until the door is properly closed.
A. When the swing-through door is closed, the relock delay time begins
and the reed switch in the lock detects the sensor magnet in the strike
plate.
B. The bolt projects after relock delay time expires and keeps projecting
until the door is closed in the correct position and locked.
C. After the bolt is projected to lock the door, the current draw will drop
to the normal state.
D. The reed switch will automatically switches off at the same time when
the door is locked.
Copyright All rights reserved. - - Published on 2016.08.25INIM-BEMP© U
Mortise Mount
Surface Mount (-S Model)
EB180, EB185
EB190TG, EB195TG
EB195TGS EB195TGVGL
Glass Mount (-VGL Model)
B. Pull in
C. Holding D.
A
Time (seconds)
Current Draw (mA)
Dimensions (Mortise Mount)
Unit: mm
Series
Series
For double or single action doors
201
56
3
1
56
31
212
56
14
53.5
56
102
53.5
2
1
2
Mortise Mount Installation (For Hollow Metal Doors)
Please refer to the particular template for each specific
cutting size and location to drill the screw holes.
Installation Instructions
Ensure that the door frame can accommodate the lock
body. Also check if it is possible to place the wires inside
the door frame.
Ensure that the double action door swings back to the correct
position so the dropbolt can lock up immediately.
Check if the regulated power supply or controller provides the
correct current draw (Pull-in current: 0.9A/12VDC, holding
current: 0.3A/12VDC).
Copyright All rights reserved. - - Published on 2016.08.25INIM-BEMP© U
Dimensions (Surface Mount)
EB195TGS
EB195TGVGL
(For full glass doors)
Warning:
1. The connection of an incorrect voltage may result in damage
and is not covered by the product warranty.
Mortise cutout in tube
Attach fixing lugs Connect the power
Assemble the lock and test it
Unit: mm
2. Select the appropriate power supply cable to ensure if the
lock receives sufficient power to operate.
3. This product has been designed for use in weather protected
areas and normal circumstances, hence it does not require
any maintenance. DO NOT OIL OR LUBRICATE
4. This product must be used in conjunction with a quality floor
spring or door closer to ensure positive realignment on closing.
Copyright All rights reserved. - - Published on 2016.08.25INIM-BEMP© U
Installation Instructions
1. Make sure the installation location and clean the surface of
glass.
2. Take off the sticker on the back of the spacer and attach the
spacer to glass. Each VGL bracket is 14mm width and spacer
is 1mm thickness. Add more spacers if needed according to
glass thickness. Use silicon to secure the VGL bracket firmly.
3. Tighten the set screws with the Allen wrench, secure the dropbolt
to the glass bracket, and then install the cover.
Caution:
1. It is suggested to attach the spacer to the inside of the door.
2. Tighten the set screws lightly to prevent breaking the glass.
Surface Mount Installation (For EB195TGS)
Header
Lock Body
Blind Nut
Blind Nut
M6 x40 Screw
M6 x40 Screw
Door
Leaf
Door
Leaf
Strike Plate
Header
Blind Nut
Blind Nut
Ins
w
i
n
g
Glass Mount Installation (For EB195TGVGL)
Set Screw
Ins
w
i
n
g
Set Screw
Glass thickness
is 10 or 12mm
Sp
a
c
e
r
Fr
a
me
l
e
s
s
G
l
a
s
s
W
a
ll
F
r
a
me
l
e
ss Gla
s
s
Doo
r
S
p
a
ce
r
2
1
2
3 4 5
Installing Blind Nuts
Blind Nut Assembly
Blind nut
Nut
Washer
Hex screw
Drill a 9.4mm hole and hammer the
blind nut assembly into the hole.
Allen wrench
Use a wrench or vice-grip to tightly
hold the nut. Then use the included
Allen wrench to slowly tighten the
screw until it does not turn any
further.
This compresses the blind nut so
that it remains permanently fixed
in the hole.
Remove the installation tool from
the blind nut. Repeat step 2
through 4 for the other blind nuts.
Installation
tool
Trouble Shooting
Problem Possible Cause Solution
Dropbolt is not activated
when the door is closed
Bolt keeps projecting
Bolt cannot retract
Copyright All rights reserved. - - Published on 2016.08.25INIM-BEMP© U
The gap between the strike plate
and the dropbolt is large
Low voltage /current
Low voltage/current
Dropbolt is not locked properly
Strike plate is misaligned
Change the sensing range to less than 5mm.
Check the output voltage and the current draw.
(Pull-in current: 0.9A/12VDC)
Check the output voltage and the current draw.
(Pull-in current: 0.9A/12VDC)
Adjust the door closer or the door hinge so that the
door is closed in the correct position.
Use on single action doors If the door hinge
cannot be adjusted.
Move or sway the door to release the bolt to open the door.
Use on single action doors If the door hinge cannot be adjusted.
Connecting Diagrams
Caution:
Make sure that the “+” and “-” wires are connected correctly. Failure to observe polarity will result in a short circuit and is not covered
by product warranty.
EB190TG/EB195TG EB180/EB185
Crimp connectors are provided to make wiring connections easier
and more reliable. To install the connectors:
1. Insert the wires into the connector.
2. Use a crimping tool or pliers to evenly press down on the head
of the connector.
Installing the Crimp Connectors:
Power
supply
Access Control(s)
Bolt status sensor output
Rating: 3A/30VDC
Door position status output
Rating: 0.25A/30VDC
Push Button
Trigger Input (N.O.)
Trigger
Relock Time Setting
0 second 3 seconds 6 seconds 9 seconds
Power
supply
Bolt status sensor output
Rating: 3A/30VDC
Relock Time Setting
0 second 3 seconds 6 seconds 9 seconds
Access Control(s)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Gianni Industries EB195TGVGL Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI