4-1 Troubleshooting
Maintenance
Detailed Settings
Convenient Setting Features
MODE
MODE
MODE
MODE
B
A
MODE
MODE
B
A
● Troubleshooting
UP/DOWN
1. Function Selection Enabling 4 to 15
Basic setting
Detailed setting
MODE
2. Detection Function Changing Response Time
UP/DOWN
STND
Standard
Mode
SHS Super
High-speed Mode
GIGA Giga Mode HS High-speed
Mode
4. BANK Switching Set values are saved for each configured bank.
UP/DOWN
BANK1
BANK2 BANK3 BANK4
5. Tolerance setting (HIGH) Configure HIGH tolerance value for tolerance judgment.
Tolerance setting
(HIGH)
MODE
UP/DOWN
13. Eco Function Saving Power Consumption
Eco function
OFF
Eco function ON
The indicators (white digital) turn OFF.
They turn ON for approx. 10 seconds and then turn OFF
by button operation.
Move to Detection Mode by holding the button for 3 seconds or longer.
MODE
A
3. Output Mode Selection Specify signal assignment to two output wires.
UP/DOWN
Normal
Output
Mode
UP/DOWN
7. Reference Point Use Setting
Select whether using the measuring unit reference point or setting the
point at power ON as origin.
Using measuring unit
Origin at Power On
MODE
User Save: The current settings are saved.
User Reload: The saved settings are loaded.
Preset Function
UP/DOWN
14. Hysteresis width
Standard
setting
Standard
setting
User setting
User setting input
MODE
UP/DOWN
15. Writing to EEPROM of External Input
Note) After finish the setting, if the measuring unit which measuring length differs
is re-connected, the setting value will be initialized.
ON
OFF
The settings that have been changed by an external input
with "oFF" will not be overwritten to prevent EEPROM
from reaching its lifespan (100,000 writings).
Set the hysteresis width . Hysteresis width is provided for
threshold to prevent the judgment output from becoming
unstable near the boundaries.
*
If chattering occurs, check the output stability while
setting the hysteresis width.
*
Usually, set the value to zero,
The hysteresis width can be set by button.
(from 0.0000 to 9999.9999, in 0.0001 step, with initial
value of 0.0001)
UP/DOWN
Reference point search again
(to capture the measuring unit reference point again)
SHS
HS
STND
GIGA
Response time
3 ms
10 ms
100 ms
1000 ms
Average Count
1
8
98
998
Measurement Cycle
1 ms
1 ms
1 ms
1 ms
Output line
Control Output 2
NoGO
Judgment
OFF ONOFF
Error Judgment/
Undetermined
GO
Judgment
Control Output 1 OFF OFFON
Phenomena
Nothing is shown on the
indication.
The digital tolerance indicator
restarts during operation.
Input signal is not received. Are the external input settings
OFF?
Is the power supply ON?
Are the cables not broken?
Check the wiring and measuring unit,
the power supply voltage and capacity.
Nothing is shown on the
digital indication. Is the Eco Function not turned
ON ?
Turn OFF the Eco function.
The measured value is not
displayed in 0.0001 step
Have the display digits
configuration properly ?
Configure it properly.
The judgment output is not
properly provided
Have the tolerance setting and
hysteresis properly
configured?
Configure the tolerance setting
and hysteresis properly.
Lost tracking of the settings
made. –Reset the settings.
Check the wiring and external input
settings.
→ Refer to "1-2 Input/Output Circuit
Diagram".
→ Refer to "1-2 Input/Output Circuit
Diagram".
Cause Remedy
→ Refer to "5 Detailed Settings".
→ Refer to "5 Detailed Settings".
→ Refer to "5 Detailed Settings".
→ Refer to "5 Detailed Settings".
● Status Display
The key lock
function enabled
Cancel the key lock function.
Lock ON
→ Refer to "3 Convenient Setting Features"
The measured values for the
number of moving average
count is being acquired from
the measuring unit.
Please wait until the moving average result is calculated
Moving average count unreached
RemedyCauseError Name / Display
The measured value is
over the display upper
limit (9999.9999).
Review the preset value.
Have the measuring unit pass the reference point (the point the
measuring unit is pressed in by 1.5 mm or more from where it is
fully extended).
Measured value upper limit error
The measured value is
under the display lower
limit (-1999.9999).
Review the preset value.
Measured value lower limit error
The measuring unit did
not pass the reference
point.
Model
NPN output
PNP output
Control output
External input*4
Minimum display unit
Power supply voltage
Power consumption*1
Control output*2
Protection circuit
Number of banks
Ambient temperature
range*3
Ambient humidity range
Mass
Cable lengs
MF10-P1
MF10-P2
2
1
0.1 μm
10 to 30 VDC, including ripple (p-p) 10%
Power supply voltage 24 V:Normal mode: 2040 mW max.(Power consumption 85 mA max.)
Power saving ECO: 1920 mW max.(Power consumption 80 mA max.)
Load voltage: 30 VDC max., open collector output type
Load voltage: The total of the two outputs must be 100 mA max.
Residual voltage and load current less than 10 mA: 1 V max.
Load current 10 to 100 mA: 2 V max.
Off state current: 0.1 mA max.
Power supply reverse polarity protection, output short-circuit protection and output
incorrect connection protection
4
Operating: When lining up 1 or 2 digital tolerance indicators: 0°C to 55°C
Storage: –10°C to 60°C (with no icing or condensation)
Operating and storage: 35% to 85% RH (with no condensation)
Approx. 75 g
2 m
(
)
RemedyCauseError Name / Display
● Error Display
The judgment output
line is short circuited.
Turn off the power supply, check whether the output line is short
circuited or not, and then turn on the power supply again.
Load short circuit detection error
An error is found in
the digital tolerance
indicator setting memory.
Turn ON the power again. Reset the settings if the error is not
corrected.
Digital tolerance indicator
EEPROM error
A connection error is
found in the measuring
unit.
Check if the measuring unit is correctly mounted, and turn ON
the power supply again.
Overcurrent protection error
A communications error
is found between the
measuring unit and the
digital tolerance
indicator.
Turn OFF the power supply and check if the measuring unit and
digital tolerance indicator are correctly connected, and then turn
ON the power supply again. If the error persists, the measuring
unit or digital tolerance indicator is broken. Replace the
measuring unit or digital tolerance indicator.
Measuring unit communications
time-out error
An error is found in
measuring unit
setting
memory.
The speed of passing the
reference point was too
high.
A measuring unit circuit
failure
Turn OFF the power supply and check if the measuring unit is
correctly connected, and then turn ON the power supply again.
If the error persists, the measuring unit is broken.
Replace the measuring unit.
Check that excessive impact is not applied to the measuring unit.
Turn ON the power supply again or perform the reference point
research.
Check if the measuring unit is correctly mounted, and then turn
ON the power supply again. If the error persists, the measuring
unit is broken. Replace the measuring unit.
Measuring unit memory error
Measuring unit speed error
Measuring unit signal level error
Set any preset value for the criteria position and perform measurement and judgment output.
The preset value on factory shipment is 0, which can be used for zero-resetting.
1. Press and hold [MODE] and [NO/NC] buttons for 3 seconds or longer.
* Reference Point Use Setting is ON: The reference point is not acquired yet (hyphen).
Pass the measuring unit reference point. Reference Point Use Setting is OFF: Set the position at execution to the preset value.
Enable
1. Select [Setting Mode] → [Preset Input Value] and set any value.
Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
2. Under the [Detection Mode], press and hold [ST] and [UP] buttons for 3 seconds or longer.
Cancel
1. Under the [Detection Mode], press and hold [ST] and [DOWN] buttons for 3 seconds or longer.
* When the reference point use setting is ON, the reference position information is saved and can be recovered after power OFF.
* A preset value can be configured within a range from -1999.9999 to 9999.9999. (in 0.0001 step with initial value of 0)
* To prevent EEPROM to reach its life for writing (100,000 times), it is recommended that writing to EEPROM should be
turned OFF by selecting [Setting Mode] → [Writing to EEPROM from External Input] if presetting is performed for each
measurement by the external input.
Enable Cancel
Hybrid Output Mode
■Normal Output Mode *For NO (Normal Open)
* If the judgment output mode is [Normal Detection Mode ], the output is provided in the
[Normal Output] pattern regardless of the setting.
The value is used to calculate the HIGH tolerance value for performing tolerance
Judgment.
*The preset value configured in BANK is reflected when BANK is switched.
When the value flickers due to vibration or other factors,
the value can be stabilized by averaging.
Output line
Control Output 2
LOW
Judgment
ON OFFON
Error Judgment/
Undetermined
GO
Judgment
Control Output 1 OFF OFFON
OFF
HIGH
Judgment
ON
■Hybrid Output Mode
The external output is
reversed when NC
(Normal Close).
The indicator is not
reversed.
The tolerance value can be set by buttons.
(from -199.9999 to 999.9999, in 0.0001 step, with initial value of 0.1)
UP/DOWN
Enter tolerance
HIGH value
MODE
6. Tolerance setting (LOW) Configure LOW tolerance value for tolerance judgment.
Tolerance setting
(LOW)
MODE
Enter tolerance
LOW value
MODE
UP/DOWN
8. Direction Specify a direction to increment/decrement the measured value.
Normal
Reverse
MODE
For normal (nor) case: The pressing-in direction is +.
For reversed (rEv): The pressing-in direction is -.
UP/DOWN
9. Judgment Output Mode Change the judgment output mode.
Area
Detection
Mode
Normal Detection Mode
10. External Input A type of external input is changed.
UP/DOWN
Preset
BANK Switching
BANK 1 if OFF,
BANK2 if ON.
Switching to BANK3
or 4 by external input
is not available.
Input OFF Tuning
1st point
Less than
3 seconds
3 sec min.
2-point setting
2-point area setting
1-point setting
± tolerance setting
2st point
Less than
3 seconds
–
When judgment setting [in tUnE] is selected, short circuit time
must be the same as the key input time.
MODE
11. Display Digits Set the number of digits to display under the detection mode.
UP/DOWN
0.1 μm step
1μm step 10 μm step
100 μm
step
MODE
12. Preset Input Value
Preset Input
Value
MODE
MODE
Preset Input Value
The preset value can be set by button.
(from -1999.9999 to 9999.9999, in 0.0001 step, with initial value of 0)
Pressing and holding the button allows quick setting.
UP/DOWN
Reference Point Use Setting
Using the measuring unit reference point/Setting the point at power ON as origin
MODE
MODE
Reference point not acquired
The value is used to calculate the LOW threshold value for performing tolerance
judgment.
→ Refer to "3 Convenient Setting Features"
Area Detection Mode: The threshold values are set as HIGH/LOW. Judgment
(display/output) is done with three levels; (HIGH) if the
value exceeds the HIGH threshold value, (LOW if the value
falls under the LOW threshold value, and (GO) if the value
is within the tolerable range.
Normal Detection Mode: The threshold value is set and the judgment is done for
non-defect (GO) or defect (NoGO).
* Judgment is made for measured value including non-display
digit s (in 0.1μm step).
→ See Preset Function in "3 Convenient Setting Features"
Press UP button once
or press DOWN button twice
→ Refer to "3 Convenient Setting Features"
* Pay attention that this setting is not reflected until the power is
turned OFF then ON again or the origin is searched again.
MODE MODE
Setting Reset
Initializing Settings
UP/DOWN
Initialize all settings to the factory-set defaults.
Hold both for 3 sec. or longer
User Save Function
User Reload Function
MODE MODE
UP/DOWN UP/DOWN
MODE MODE
UP/DOWN
User Save Function/User Reset Function
Saving/Reading Settings
Hold both for 3 sec. or longer
Enable/Cancel
(The same procedure)
Key Lock Function
Preventing Malfunction
Disables all the button operations.
* Press either of UP/DOWN.
Hold both for 3 sec. or longer
Hold both for 3 sec. or longer
Hold both for 3 sec. or longer Hold both for 3 sec. or longer
NPN output
PNP output
Contact input (Relay or switch)
ON: Short circuit to 0 V
(Outflow current: 1 mA max.)
OFF: Open or short circuit to Vcc
ON: Short circuit to Vcc
(Sink current: 3 mA max.)
OFF: Open or short circuit to 0 V
Non-contact input (Transistor)
ON: 1.5 V max. (Outflow current: 1 mA max.)
OFF: Vcc-1.5 V to Vcc
(Leakage current: 0.1 mA max.)
ON: Vcc-1.5 V to Vcc (Sink current: 3 mA max.)
OFF: 1.5 V max.
(Leakage current: 0.1 mA max.)
Input time
ON: 2 ms min.
OFF: 20 ms min.
*1. Power supply voltage 10 V to 30 V:
Normal mode: 2250 mW max.(Power supply voltage 30 V: Power consumption 75 mA max./Power supply voltage
10 V: Power consumption 155 mA max.)
Power saving ECO: 2100 mW max. (Power supply voltage 30 V: Power consumption 70 mA max./Power supply
voltage 10 V: Power consumption 135 mA max.)
*2. When lining up 4 or more digital tolerance indicators, the 2 output total is 20 mA or less.
*3. When used in a row, operating ambient humidity ranges are:
3 to 10: 0 to +50 11 to 16: 0 to +45 , 17 to 30: 0 to +40
*4. Details on inputs are as follows:
Hold button for 3 seconds or longer to enter Setting mode.
MODE
Setting mode provides the function settings described hereafter. The
initial display shown after transition from one function to another
represents the factory default.
Function Selection: [ ]
Function Selection: [ ]
The tolerance value can be set by buttons.
(from -199.9999 to 999.9999, in 0.0001 step, with initial value of -0.1)
UP/DOWN
1. Select [Setting Mode ] → [Reference Point Use Setting].
ON : The unit automatically waits for the reference point signal. When the reference point is used,
turn on the power with the spindle extended as far as possible, and then move the spindle 1.5
mm or more. A measured value is displayed.
OFF : The reference point is set as the position of the measuring unit at power ON, and the
measured value is displayed.
The displayed value is the preset value.
* After the setting, turning the power OFF then ON, or searching the reference point again, reflects
the reference point use setting to measurement.
* When the reference point use setting is ON, a hyphen mark (-) is displayed until the measuring
unit passes the reference point.