Multi-parameter transmitter M800 Pronet and Ethernet / IP Process 5
© 05/2020 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Multi-parameter transmitter M800 Pronet and Ethernet / IP Process
Printed in Switzerland 30 530 036 B
7.3 Calibration of Cond 4-e Sensors _____________________________________________________________________ 36
7.3.1 One-Point Calibration _____________________________________________________________________ 37
7.3.2 Two-Point Calibration _____________________________________________________________________ 37
7.3.3 Process Calibration _______________________________________________________________________ 38
7.4 pH Calibration ___________________________________________________________________________________ 38
7.4.1 One-Point Calibration _____________________________________________________________________ 39
7.4.2 Two-Point Calibration _____________________________________________________________________ 39
7.4.3 Process Calibration _______________________________________________________________________ 40
7.5 ORP Calibration of pH Sensors ______________________________________________________________________ 40
7.6 Calibration of Amperometric Oxygen Sensors ___________________________________________________________ 41
7.6.1 One-Point Calibration _____________________________________________________________________ 41
7.6.2 Process Calibration _______________________________________________________________________ 42
7.7 Calibration of Optical Oxygen Sensors ________________________________________________________________ 43
7.7.1 One-Point Calibration _____________________________________________________________________ 43
7.7.2 Two-Point Calibration _____________________________________________________________________ 44
7.7.3 Process Calibration _______________________________________________________________________ 44
7.8 Calibration of Dissolved Carbon Dioxide Sensors ________________________________________________________ 45
7.8.1 One-Point Calibration _____________________________________________________________________ 45
7.8.2 Two-Point Calibration _____________________________________________________________________ 46
7.8.3 Process Calibration _______________________________________________________________________ 46
7.9 Calibration of Thermal Conductivity CO
2
(C0
2
High) Sensors _______________________________________________ 47
7.9.1 One-Point Calibration ______________________________________________________________________ 47
7.9.2 Process Calibration _______________________________________________________________________ 48
7.10 Turbidity Calibration ______________________________________________________________________________ 48
7.10.1 Process Calibration _______________________________________________________________________ 49
7.11 Sensor Verication ________________________________________________________________________________ 50
7.12 UniCond 2-e Electronics Calibration __________________________________________________________________ 50
7.13 Meter Calibration _________________________________________________________________________________ 50
7.13.1 Voltage _________________________________________________________________________________ 51
7.13.2 Current _________________________________________________________________________________ 51
7.13.3 Rg ____________________________________________________________________________________ 51
7.13.4 Rr _____________________________________________________________________________________ 52
7.14 Analog Input Calibration ___________________________________________________________________________ 52
7.15 Maintenance ____________________________________________________________________________________ 52
8 Conguration _________________________________________________________________________________________ 53
8.1 Measurement ___________________________________________________________________________________ 53
8.1.1 Channel Setup ___________________________________________________________________________ 53
8.1.2 Derived Measurements ____________________________________________________________________ 54
8.1.2.1 % Rejection Measurement ________________________________________________________ 54
8.1.2.2 Calculated pH (Power Plant Applications Only) ________________________________________ 54
8.1.2.3 Calculated CO
2
(Power Plant Applications Only) _______________________________________ 55
8.1.3 Display Mode ____________________________________________________________________________ 55
8.1.4 Parameter Related Settings _________________________________________________________________ 56
8.1.4.1 Conductivity Settings ____________________________________________________________ 56
8.1.4.2 pH Settings ___________________________________________________________________ 57
8.1.4.3 Settings for Oxygen Measurement Based on Amperometric Sensors ________________________ 58
8.1.4.4 Settings for Oxygen Measurement Based on Optical Sensors _____________________________ 59
8.1.4.5 Dissolved Carbon Dioxide Settings _________________________________________________ 60
8.1.4.6 Settings for Thermal Conductivity Dissolved CO
2
Measurement (CO
2
hi) _____________________ 61
8.1.4.7 Settings for Turbidity Sensors (InPro 8000 Series) _____________________________________ 62
8.1.4.8 Settings for Turbidity Sensors ______________________________________________________ 62
8.1.5 Concentration Curve Table __________________________________________________________________ 62
8.2 Set Points ______________________________________________________________________________________ 63
8.3 ISM Setup ______________________________________________________________________________________ 64
8.3.1 Sensor Monitor ___________________________________________________________________________ 64
8.3.2 CIP Cycle Limit ___________________________________________________________________________ 65
8.3.3 SIP Cycle Limit ___________________________________________________________________________ 66
8.3.4 AutoClave Cycle Limit _____________________________________________________________________ 67
8.3.5 DLI Stress Adjustment _____________________________________________________________________ 68
8.3.6 SAN Cycle Parameters _____________________________________________________________________ 68
8.3.7 Reset Counters for UniCond 2-e Sensors _______________________________________________________ 68
8.3.8 Set Calibration Interval for UniCond 2-e Sensors _________________________________________________ 69
8.4 General Alarm ___________________________________________________________________________________ 69
8.5 ISM / Sensor Alarm ________________________________________________________________________________ 69
8.6 Clean _________________________________________________________________________________________ 70
8.7 Display Setup ___________________________________________________________________________________ 70