Danfoss SpeedUp - Direct load User guide

Type
User guide

Danfoss SpeedUp - Direct load offers an efficient and versatile solution for underfloor heating systems. Its innovative design allows for direct installation of parquet flooring, providing a comfortable and energy-saving heating solution for your home. With its slim profile and high thermal conductivity, SpeedUp ensures optimal heat distribution while minimizing construction height. Experience the benefits of efficient heating and a comfortable indoor climate with Danfoss SpeedUp - Direct load.

Danfoss SpeedUp - Direct load offers an efficient and versatile solution for underfloor heating systems. Its innovative design allows for direct installation of parquet flooring, providing a comfortable and energy-saving heating solution for your home. With its slim profile and high thermal conductivity, SpeedUp ensures optimal heat distribution while minimizing construction height. Experience the benefits of efficient heating and a comfortable indoor climate with Danfoss SpeedUp - Direct load.

Application sheet
SpeedUp
Parquet
Direct load
1
2
3
4
5
1 Parquet ≥ 14 mm
2 Sound insulation 2 mm
3 If necessary moisture barrier
4 SpeedUp heat panel + FH composite pipe 30 mm
5 Support batten (30mm)
6 SpeedUp perimeter insulation
Floor nish ≥ 14 mm Parquet
Construction height ≥ 46 mm Height including parquet
Weight ~ 13 kg / m² Weight including parquet
Thermal resistance R 0,86 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 0,97 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 2,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 14 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Oce spaces, hallways in oce buildings, medical oces, stations and spaces with
human occupancy, and commercial spaces with oor areas up to 50 m² in residential or
oce buildings. Corresponds to categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Header panels and cut modular panels at the edges of the area must be glued to the
unnished oor.
If necessary, protect oorboards and prefabricated parquet against moisture penetra-
tion from below (vapour barrier).
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
This construction applies to residential partition slabs between rooms at the same tem-
perature. No additional insulation is necessary. See “Overview of maximum additional
insulation” with regard to allowable equalisation insulation.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 38
Technical Data Floors/ceilings between rooms at the same temperature
6
© Danfoss 11/2008
VA.CR.G1.02
Danfoss HES
  • Page 1 1

Danfoss SpeedUp - Direct load User guide

Type
User guide

Danfoss SpeedUp - Direct load offers an efficient and versatile solution for underfloor heating systems. Its innovative design allows for direct installation of parquet flooring, providing a comfortable and energy-saving heating solution for your home. With its slim profile and high thermal conductivity, SpeedUp ensures optimal heat distribution while minimizing construction height. Experience the benefits of efficient heating and a comfortable indoor climate with Danfoss SpeedUp - Direct load.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI