Application sheet
SpeedUp
Carpet / tiles / parquet / laminate / synthetics
Cement-screed
1
2
3
4
5
1 Carpet / tiles / parquet
2 Cement-screed (≥ CT-F4) 45 mm
3 System foil
4 SpeedUp heat panel + FH composite pipe 30 mm
5 Support batten (30mm)*
6 Basic perimeter insulation
7 Sound insulation 6/8 mm 6 mm
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 81 mm Height excluding oor nish
Weight ~ 93 kg / m² Weight excluding oor nish
Thermal resistance R 0,97 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 0,87 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN
Impact subsonic noise reduction 27 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
The screed thicknesses must be adjusted in case of higher design load or point load
values.
* Construction without a stabilising support batten is also possible.
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
This construction applies to residential partition slabs between rooms at the same tem-
perature. No additional insulation is necessary. See “Overview of maximum additional
insulation” with regard to allowable equalisation insulation.
Construction
according to EnEV, EN 1264, DIN 1055, 18202 and 4108
Construction number 44
Technical Data Floors/ceilings between rooms at the same temperature
6
7
© Danfoss 11/2008
VA.CR.I1.02
Danfoss HES