Danfoss SpeedUp Eco - Liquid screed User guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp Eco - Liquid screed User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application sheet
SpeedUp Eco
Carpet / tiles / parquet / laminate / synthetics
Liquid screed
1
2
3
4
5
1 Carpet / Tiles / Parquet
2 Liquid screed (≥ CAF F5) 35 mm
3 SpeedUp Eco system foil
4 SpeedUp Eco heat panel + FH composite pipe 30 mm
5 Support batten (30mm)*
6 SpeedUp Eco perimeter insulation
7 If necessary moisture barrier
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 65 mm Height excluding oor nish
Weight 78 kg / m² Weight excluding oor nish
Thermal resistance R 0,75 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 1,09 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN
Impact subsonic noise reduction 24 dB Calculation value according to DIN 4109 on massive construction
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
For CAF-F4 self-levelling screeds a screed thickness of 40 mm must be maintained. The
screed thicknesses must be adjusted in case of higher design load or point load values. *
Construction without a stabilising support batten is also possible. Observe all installa-
tion instructions and manufacturer’s instructions.
Additional insulation
This construction applies to residential partition slabs between rooms at the same tem-
perature. No additional insulation is necessary. See “Overview of maximum additional
insulation” with regard to allowable equalisation insulation.
Construction
According to EnEV, EN 1264, DIN 1055, 18202, 18560, 4108 and 4109
Construction number 96
Technical Data Floors/ceilings between rooms at the same temperature
6
7
© Danfoss 11/2008
VA.CS.Q1.02
Danfoss HES
/