Application sheet
SpeedUp
Laminate
Strongboard tile and laminate
1
2
3
4
5
1 Laminate ≥ 8 mm
2 Strongboard tile and laminate 5 mm
3 If necessary moisture barrier
4 SpeedUp heat panel + FH composite pipe 30 mm
5 Support batten (30mm)
6 SpeedUp perimeter insulation
Floor nish ≥ 8 mm Laminate; strength without subsonic noise lamination
Construction height ≥ 43 mm Height including oor nish
Weight ~ 15 kg / m² Weight including oor nish
Thermal resistance R 0,86 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 0,97 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 2,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 19 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Oce spaces, hallways in oce buildings, medical oces, stations and spaces with
human occupancy, and commercial spaces with oor areas up to 50 m² in residential or
oce buildings. Corresponds to categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Header panels and cut modular panels at the edges of the area must be glued to the
unnished oor.
Protect laminate against moisture penetration from below if necessary (vapour barrier).
Strongboard is used under the laminate as a structural and subsonic noise reduction
layer.
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
This construction applies to residential partition slabs between rooms at the same tem-
perature. No additional insulation is necessary. See “Overview of maximum additional
insulation” with regard to allowable equalisation insulation.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 41
Technical Data Floors/ceilings between rooms at the same temperature