4
7301793-100 Rev. D
INSTALL AND CONNECT MIXING VALVE
(MIXING VALVE IS OPTIONAL)
CONNECT MIXING VALVE TO WATER SUPPLIES
11
10
12
ELECTRICAL HOOK-UP AND INSTALLATION
COLD WATER
OR TEMPERED
WALL SUPPLY
ELECTRONIC
BOX
1
2
4
3
3
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Proximity ICU Faucet
Certified to comply with ASME A112.18.1M
© 2011 American Standard
To learn more about American Standard Faucets visit our website at: www.americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-306-1093)
M965119
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ, s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055.193
6056.193
MODEL NUMBERS
6055 / 6056 ICU Faucet shown Installed on
American Standard 9118.111 ICU Sink
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
ENCLOSURE (2).
2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to FLEXIBLE
SUPPLY HOSE (3). Tighten to make a water tight connection. Use
two wrenches to tighten if necessary.
3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.
Connection on FLEXIBLE SUPPLY (3) is 3/8" compression. Use
adjustable wrench to tighten connection. Do not over tighten.
Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom of
the ENCLOSURE (1) base. If additional supply length is
required, installer must purchase parts separately. Important: If
FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.
9
CONNECT WATER SUPPLY TO ENCLOSURE
AND TO COLD OR TEMPERED WALL SUPPLY
1. Remove COVER from MIXING VALVE.
2. Install FIBER SEAL WASHER (4) on MIXING VALVE
NIPPLE (3). Hold MIXING VALVE (1) in place with one hand
and with your other hand thread SWIVEL NUT (2) onto
MIXING VALVE NIPPLE (3). Use an adjustable wrench to
tighten SWIVEL NUT (2).
3. Place MIXING VALVE BOX onto MOUNTING PLATE. Align
BOX with mounting holes. Attach with SCREWS provided.
4. Replace COVER and tighten securely.
NOTE: For complete detailed installation and
operating instructions see installations instructions
supplied with mixing valve. No. M968808
For complete detailed installation and operating instructions see
installations instructions supplied with ICU FAUCET. No. M965119
1
2
1
2
3
4
2
ADJUSTABLE
WRENCH
HOT
MIXING VALVE
ELECTRONIC
BOX
COLD
1. Turn off Hot and Cold water supplies before beginning.
2. Connect FLEXIBLE SUPPLIES directly to wall supplies.
Connections on MIXER supplies are 3/8" compression. Connect left
supply to Hot and right supply to Cold wall supply. Use adjustable
wrench to tighten connections. Do not over tighten.
3. Faucet supplies measure 20" from the bottom of the
ENCLOSURE (3) base.
Note: If additional supply length is required, installer must
purchase parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop as to
avoid kinking.
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
No. M965119