Digital Monitoring Products XTLC User guide

Type
User guide
INSTALLATION GUIDE
XTLC PANEL
MODEL XTLC
INSTALLATION GUIDE
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changesormodicationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’s
authority to operate the equipment.
This device has been designed to operate with the integrated 1100 Series PCB antenna having a maximum gain of
1.8 dB. Antennas having a gain greater than 1.8 dB are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
If necessary, the installer should consult the dealer or an experienced radio/television technician for additional
suggestions.Theinstallermayndthefollowingbooklet,preparedbytheFederalCommunicationsCommission,
helpful:
“How to identify and Resolve Radio-TV Interference Problems.”
ThisbookletisavailablefromtheU.S.GovernmentPrintingOfce,WashingtonD.C.20402
StockNo.004-000-00345-4
©2015DigitalMonitoringProducts,Inc.
InformationfurnishedbyDMPisbelievedtobeaccurateandreliable.
This information is subject to change without notice.
XTLC Installation Guide Digital Monitoring Products
i
TABLE OF CONTENTS
Panel Specications
1.1 Power Supply .............................................................................1
1.2 Communication ...........................................................................1
1.3 Keypads .....................................................................................1
1.4 Number of Zones ........................................................................1
1.5 EnclosureSpecications ..............................................................1
Introduction
2.1 SystemCongurations .................................................................1
2.2 Caution Notes .............................................................................1
2.3 Compliance Instructions ..............................................................1
System Components
3.1 Accessory Devices .......................................................................2
Installation
4.1 MountingLocationInformation ....................................................3
4.2 MountingtheEnclosure ...............................................................3
Primary Power Supply
5.1 DC Input ....................................................................................3
Secondary Power Supply
6.1 Standby Battery ..........................................................................4
6.2 Replacement ..............................................................................4
6.3 Battery Supervision .....................................................................4
LED Operation
7.1BacklitLogo ....................................................................................5
RESET Button
8.1 Description .................................................................................5
Programming (PROG) Connection
9.1 ProgrammingConnection ............................................................5
On-Board 1100 Series Wireless
10.1 Wireless Antenna ........................................................................5
10.2 WirelessLEDOperation ...............................................................5
Wireless Keypads
11.1 MountingKeypads ......................................................................6
11.2 Wireless Keypad Association ........................................................6
Wireless Zones
12.1 Description .................................................................................6
Wireless Key Fobs and Outputs
13.1 Description .................................................................................6
Flash LOAD Button
14.1 Description ................................................................................6
Listed Compliance Specications
15.1 Introduction ...............................................................................8
15.2 UseMarking ...............................................................................8
15.3 NFPA 72 .....................................................................................8
15.4 TypesOfService .........................................................................8
15.5 Bypass Reports ...........................................................................8
15.6 Battery Standby ..........................................................................8
Digital Monitoring Products XTLC Installation Guide
ii
TABLE OF CONTENTS
Household Burglar-Alarm System Units
ANSI/UL 1023
16.1 Bell Cutoff ..................................................................................8
16.2 Entry Delay ................................................................................8
16.3 Exit Delay ...................................................................................8
16.4 Wireless External Contact ............................................................8
16.5 Wireless Supervision Time ...........................................................8
16.6 Wireless Audible Annunciation .....................................................8
16.7 Panel location .............................................................................8
16.8 Test Frequency ...........................................................................8
Central Station Burglar Alarm Units
ANSI/UL 1610
17.1 Supervision ................................................................................9
17.2 Remote Disarm ...........................................................................9
17.3 Central Station ............................................................................9
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specications
18.1 BellOutputDenition ..................................................................9
18.2 HouseholdSystem ......................................................................9
18.3 Wireless Supervision Time ...........................................................9
18.4 Test Frequency ...........................................................................9
18.5 Wired Modules ............................................................................9
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
19.1 ShippingDefaultsandRecommendedProgramming ....................10
Revisions to This Document
Revisions ...........................................................................................11
Certications
XTLC Installation Guide Digital Monitoring Products
1
SYSTEM COMPONENTS
Panel Specications
1.1 Power Supply
Input:   12VDC
StandbyBattery: 3.7VDCLithium
All circuits inherent power limited.
1.2 Communication
TheXTLCcontainsbuilt-inCellularcommunicationtoDMPModelSCS-1RorSCS-VRReceivers.Cellular
ServiceisrequiredbeforeusingtheXTLCforsignaltransmission.TheXTLCpanelisreadyforactivation
withSecureComWireless,LLC.Moreinformationisavailableatwww.securecomwireless.comorseeCellular
ActivationintheXTLCProgrammingGuide(LT-1108).
1.3 Keypads
Youcanconnectupto4alphanumeric9000Serieswirelesskeypads.
1.4 Number of Zones
•XTLChas28wirelessinitiatingzonesnumbered1-28
•ZoneandOutputnumbers31to34and41to44cansupport1100SeriesKeyFobs,OutputModules,or
sirens
1.5 Enclosure Specications
TheXTLCpanelshipsinaplasticenclosurewithauser’sguideandprogrammingsheets.
Size Color
5.5”Wx3.75”Hx1”D White(W)
Introduction
2.1 System Congurations
The panel can be programmed to operate as any of the following system types:
•All/Perimetersystemthatprovidesoneperimeterareaandoneinteriorarea
•Home/Sleep/Awaysystemthatprovidesoneperimeter,oneinterior,andonebedroomarea.Thebedroom
area provides for any protection devices the user wants disarmed during their sleeping hours and armed
in the Away mode.
•Sixareasystemthatprovidesareasofprotectionthatcanbeindependentlyarmedordisarmed.
2.2 Caution Notes
Throughoutthisguideyouwillseecautionnotescontaininginformationyouneedtoknowwheninstalling
thepanel.Thesecautionsareindicatedwithayieldsign.Wheneveryouseeacautionnote,makesureyou
completely read and understand its information. Failing to follow the caution note can cause damage to the
equipment or improper operation of one or more components in the system.
2.3 Compliance Instructions
ForapplicationsthatmustconformtoalocalauthoritiesinstallationstandardoraNationalRecognized
TestingLaboratorycerticatedsystem,pleaseseetheListedComplianceSpecicationssectionneartheend
of this guide for additional instructions
Digital Monitoring Products XTLC Installation Guide
2
INTRODUCTION
System Components
3.1 Accessory Devices
DMP Two-Way Wireless Devices
1100R Repeater Provides additional range for wireless devices.
1101UniversalTransmitter Provides both internal and external contacts that may be used at the same time to yield two
individualreportingzonesfromonewirelesstransmitter.
1102UniversalTransmitter Provides one external contact.
1103UniversalTransmitter Provides bothinternalandexternalcontactsthatmaybeusedatthesametimetoyieldtwo
individualreportingzonesfromonewirelesstransmitter.RequiresEOLresistorforexternal
contact. ProvidesDisarm/Disablefunctionality.
1106UniversalTransmitter Provides both internal and external contacts that may be used at the same time to yield two
individualreportingzonesfromonewirelesstransmitter.
1107MicroWindowTransmitter* Provides survey capability for window applications.
1114Four-ZoneExpander* ProvidesfourwirelesszoneswithEOLresisters.
1116RelayOutput* Provides one Form C relay.
1117LEDAnnunciator* Provides a visual system status indicator.
1119DoorSounder* Provides a wireless sounder with integrated door contact.
1121PIRMotionDetector* Provides motion detection with pet immunity.
1126RMotionDetector* CeilingmountmotiondetectorwithpanelprogrammablesensitivityandDisarm/Disable
functionality.
1127C/1127WPIRMotion
Detector
WallmountmotiondetectorwithpanelprogrammablesensitivityandDisarm/Disable
functionality.
1129GlassbreakDetector* Detectstheshatteringofframedglassmountedinanoutsidewallandprovidesfull-pattern
coverage and false-alarm immunity.
1131RecessedContact*
Provides concealed protection for doors, windows or other applications.
1135/1135DBSiren* Provides a wireless siren.
1139BillTrap* Provides a silent alarm option for use in cash drawers.
1141WallButton* One-buttonwirelesstransmitterdesignedtobewall-mounted.
1142BCTwo-buttonPanicBelt
Clip Transmitter
Provides portable two-button panic operation.
1142Two-buttonPanic
Transmitter
Provides permanently mounted under-the-counter two-button panic operation.
1144-4(Four-Button)*
1144-2(Two-Button)*
1144-1(One-Button)*
KeyFobtransmittersdesignedtoclipontoakeyringorlanyard.
1148PersonalPendant Wirelessemergencytransmitterdesignedtobewornasawristbandoronabreak-away
lanyard.
1161ResidentialSmokeDetector Residentialsmokedetectorwithsounder.
1162ResidentialSmokeDetector Residentialsmoke/heatdetectorwithsounderandxedrate-of-riseheatdetector.
1164WirelessSynchronized
SmokeDetector
Commercialorresidential,batterypowered,wireless,lowprole,photoelectricsmoke
detector,withsynchronizingsounder.
1183-135FHeatDetector Fixed temperature heat detector.
1183-135RHeatDetector Fixed temperature and rate-of-rise heat detector.
1184CarbonMonoxideDetector CarbonMonoxidedetector.
Interface Module
738ZZ-WaveInterfaceModule* ProvidesconnectionforZ-Wavemodules.
Keypads
9000SeriesLCDkeypads Allowsyoutocontrolthepanelfromvariousremotelocationsusing9000SeriesWireless
Keypads.
9862WirelessGraphic
TouchscreenKeypad
Allows you to control the panel from various remote locations.
* These devices have not been investigated and shall not be used in listed installations.
XTLC Installation Guide Digital Monitoring Products
3
SYSTEM COMPONENTS
Installation
4.1 Mounting Location Information
A location should be selected that is centrally located between the 1100 Series transmitters used in the
installation.InstalltheXTLCawayfrommetalobjects.Mountingthepanelonornearmetalsurfaces
impairsperformance.Whenselectingthepropermountinglocationofatransmitter,refertotheLEDSurvey
Operationsectionofthespecicinstallationguideforthetransmitterbeinginstalled.
4.2 Mounting the Enclosure
TheenclosurefortheXTLCpanelmustbemountedusingtheprovided#6screwsinthefourmountingholes
showninFigure1.Mounttheenclosureinasecure,dryplaceawayfrommetalobjectstoprotectthepanel
fromdamageduetotamperingortheelements.Mountthepanelaminimumof4feetfromanywireless
transmitters or repeaters. It is not necessary to remove the PCB when installing the enclosure.
Mounting Hole Locations
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTLC
TX RF RX
S
N
Figure 1: Mounting Hole Locations
Primary Power Supply
5.1 DC Input
MounttheXTLCpanelnearawalloutletfortheModel372-500plug-inDCpowersupply.Inadditionto
poweringthepanel,theDCplug-inpowersupplyalsochargestheback-upbattery.The372-500mustbe
locatedwithin100feetofthepanelusing22AWGwire.Usethefollowingstepstoconnecttheplug-inpower
supply:
OBSERVE POLARITY
1. Using22AWGwire,connectthepanelPWRrstterminal(+)tothepositiveterminalonthepower
supply.
2. ConnectthepanelPWRsecondterminal(-)tothenegativeterminalonthepowersupply.
3. Plugthepowersupplyintoa120VoltAC,60Hzdedicatedoutletnotcontrolledbyaswitch.
Figure2:DCPowerSupplyConnection
Wire Exit for DC
Power Supply
+
+
Model 372-500
DC Plug-in
Power
Supply
Use 22 AWG for
Power Supply connection
_
_
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTLC
TX RF RX
S
N
Digital Monitoring Products XTLC Installation Guide
4
INSTALLATION
Secondary Power Supply
6.1 Standby Battery
TheXTLCrechargeablebatteryisusedtoprovidebackupbatterypowerwhenDCpowerisnotavailable.The
batteryisintendedforbackuppoweronlyandnottooperatethepanelonadailybasis.Ifthebatteryislow,
or not plugged into the BAT battery connector, a low battery condition is indicated by the panel.
Note:Ifremovingthepanelfromservice,disconnectthebackupbatteryfromthepanelconnector.
6.2 Replacement
Usethefollowingstepstoreplacethepanelstandbybattery.DMPrecommendsreplacingthebatteryevery3
years under normal use.
1. Unplugthebatteryconnector(BAT)fromthepanel.
2. Ifinstalled,removethe2screwsfromthePCB.
3. LoosenthetopPCBsnaps.
4. LeanthepanelPCBforwardandliftoutfromthebottomPCBsnaps.
5. Remove and properly dispose of the used battery.
Caution:Riskofre,explosion,andburns.Donotdisassemble,heatabove212°F(100°C),
or incinerate. Properly dispose of used batteries.
6. Place the new battery into the housing base with the battery wires directed toward the bottom
rightcorner.SeeFigure2.
7. Set the PCB into the bottom snaps and press into the top snaps to secure in place.
8. Plugthebatteryintothepanelconnector(BAT).
6.3 Battery Supervision
ThepanelteststhebatteryonceeveryhourwhenDCpowerispresent.Thistestoccurs15minutespast
eachhourandlastsforveseconds.Aloadisplacedonthebatteryandifthebatteryvoltageislow,alow
batteryisdetected.IfDCpowerhasfailed,alowbatteryisdetectedanytimethebatteryvoltagefalls
below3.7V.
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTLC
TX RF RX
S
N
PCB Screw Locations
Top PCB Snaps
Bottom PCB Snaps Battery
connector
3.7V
Rechargeable
Battery
Figure 4: Standby Battery ReplacementFigure 3: PCB Screw Locations
XTLC Installation Guide Digital Monitoring Products
5
INSTALLATION
LED Operation
7.1 Backlit Logo
ThebacklitlogoindicatesthePowerandArmedstatusofthepanel.Dependingontheoperation,theLED
displaysinRedorGreenaslistedinthetable.
Color and Activity Operation
GreenSteady PanelDisarmed,PrimaryPowerOK,BatteryOK
GreenBlinking PanelDisarmed,PrimaryPowerOK,BatteryFault
NoLight PanelDisarmed,PrimaryPowerFault,BatteryOK
Red Steady PanelArmed,PrimaryPowerOK,BatteryOK
Red/GreenAlternate PanelArmed,PrimaryPowerOK,BatteryFault
RedBlinking PanelArmed,PrimaryPowerFault,BatteryOK
RESET Button
8.1 Description
TheRESETbuttonislocatedontherightsideofthecircuitboardandisusedtoresettheXTLC
microprocessor.Toresetthepanelpriortoreprogramming,presstheRESETbuttonwithoutpoweringdown
thesystem.Afterresettingthepanel,beginprogrammingwithin30minutes.Ifyouwaitlongerthan30
minutes, you must reset the panel again.
Programming (PROG) Connection
9.1 Programming Connection
Alocking4-pinPROGheaderisprovidedtoconnectakeypadwhenusingaDMPModel330Programming
Cable.Thisprovidesaquickandeasyconnectionforprogrammingthepanel.Afterprogrammingis
complete,removethekeypad.
Installing the 738Z
Toconnectthewiringofthe738ZtothePROGheaderofthepanel,useaPC-0140ConnectorAssembly
(includedwiththe738Z)forconnectionofaModel300harness.The738Zonlyoperateswhenprimarypower
is present.
Note:ThePROGheaderisnotintendedtoprovideaKeypadDataBusconnection.Theprogrammingkeypad
isoperationalonlywhenprimarypowerisappliedtotheXTLC.
On-Board 1100 Series Wireless
10.1 Wireless Antenna
TheXTLCWirelessAntennaisintegratedintothecircuitboard.Thebuilt-inwirelessreceiveroperateswith
DMP1100Seriestransmitters.Seesection3.1foralistofaccessorydevices.
10.2 Wireless LED Operation
Green (TX):ThegreenLEDasheseverytimethereceivertransmits(32timespersecond).Ifthepanel
isreset,orthepanelispoweredoff,thegreenLEDisoff.Undernormaloperation,thegreenLEDashes
constantly with no interruption or change.
Yellow (RX):TheyellowLEDasheseverytimetheXTLCreceivesamessagefromaprogrammedwireless
transmitter.Whenamessageissentbyatransmitter,typicallybypressingorreleasingthetamperswitch,
theyellowLEDshouldashindicatingthatthepanelreceivedamessagefromthetransmitter.IftheLED
neverashes,thetransmitterisnotgettingthroughtothepanel.Thiscouldbebecauseofamisprogrammed
serialnumberorthetransmitteristoofaraway.Undernormaloperation,theyellowLEDashesatevery
tripofeverywirelesstransmitterandwhenthetransmittersperformtheirperiodiccheck-in.Itisnot
unusualforthisLEDtostayoffformanyminutesatatimewhennotransmittersarecommunicating.
Digital Monitoring Products XTLC Installation Guide
6
INSTALLATION
Wireless Keypads
11.1 Mounting Keypads
DMPkeypadshaveremovablecoversthatallowthebasetobemountedonawall,deskstandorotherat
surface using the screw holes provided on each corner.
11.2 Wireless Keypad Association
EnableWirelessKeypadAssociationoperationonboththekeypadandpanel.
ToenablewirelesskeypadassociationoperationonaLCDWirelesskeypad(Models9060and9063),pressand
holdtheBackArrowkeyandCMDuntilSETBRIGHTNESSdisplays.
ToenableassociationoperationonaWirelessGraphicsTouchscreenkeypad(Model9862),accesstheOptions
menuthroughthecarouselmenu.WhileintheOptionsdisplay,presstheInstallerOptionsicon.
OneithertheLCDorGrapicsWirelesskeypad,enterthecode3577
(INST)atthekeypadandpressCMD.PressKPDRFtostarttheRF
surveycommunication.Thekeypaddisplaysitswirelessserialnumber
andRFSURVEY.
ThekeypadPower/ArmedLEDturnsRed,indicatingcommunication
hasnotyetbeenestablishedwiththepanelreceiver.Whensuccessful
communicationhasbeenestablished,thePower/ArmedLEDturns
BlueonGraphicskeypadsorGreenonLCDkeypads.
ToenableassociationoperationintheXTLSeriespanel,presstheXTL
SeriesRESETbuttonthreetimesallowingthewirelessTRANSMITLED
(TX)locatednearthetopofthePCBtobeginashingbetweeneach
press.Wheninkeypadassociation,theXTLSeriesRedandGreenlogo
LEDsturnonsteady.
For60secondsthepanellistensforwirelesskeypadsthatareinRF
Survey and have not been programmed, or associated into another
panel.Wirelesskeypadsareassignedtotherstopendeviceposition
inDeviceSetupautomatically,basedupontheorderinwhichthey
aredetected.ThekeypadlogoturnsGreentoindicateithasbeen
associated with the panel.
NOTE:Amaximumoffourwirelesskeypadsareallowedoneachpanel.
Wireless Zones
12.1 Description
XTLCpanelsprovide28wirelesszonesnumbered1to28.Adefaultzonename,zonetype,andarea
assignmentaredescribedintheXTLCProgrammingGuide(LT-1108)andcanbechangedinZoneInformation
programming as needed. The defaults are provided as a programming convenience to help reduce
installation time.
Wireless Key Fobs and Outputs
13.1 Description
XTLCpanelsprovide8wirelesskeyfoboroutputaddressesnumbered31to34and41to44.Adefaultname
is provided as a programming convenience to help reduce installation time. The default names are described
intheXTLCProgrammingGuide(LT-1108)andcanbechangedinOutputInformationorZoneInformation
programming as needed.
+_
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTL
TX RF RX
S
N
CR7
CR6
Red LED
Green LED
Transmit LED
Figure 5: XTLC Transmit and Receive
LEDs & Backlit Logo LEDs
XTLC Installation Guide Digital Monitoring Products
7
INSTALLATION
Flash LOAD Button
14.1 Description
TheXTLCpanelsoftwarecanbeupdatedviathepanel’sProgramming(PROG)header.Toupdatethepanel
with a new software version, complete the following steps at the protected premise:
Model 399 Cable
1. ConnectaDMP399CablefromthePROGheadertotheserialportofyourPCoperatingRemoteLink
andcontainingtheXTLCRUle.
2. StartRemoteLinkandcreateoropenthecontrolpanelaccountthatmatchesthepaneltobeupdated.
3. SettheConnectionInformationTypetoDirectwithabaudrateof38400andchoosetheappropriate
COMport.
4. SelectPanel>RemoteUpdate,thenselectthecorrectRUleforthepanel.
5. PressandholdtheLOADbutton,thenpressandreleasetheRESETbutton.
6. ReleasetheLOADbuttonandclick<Update>inRemoteLink.
7. Afterthesoftwareupdateiscompleted,removethe399cableandpresstheRESETbuttontoresume
normal panel operation.
Model 400 USB Flash Module
1. PressandholdtheLOADswitch.WhileholdingtheLOADswitch,pressandreleasetheRESETswitch
2. ReleasetheLOADswitch.
3. ConnecttheUSBashdrivetotheModel400andconnecttheassemblytothepanelsPROGheader.
TheLEDontheModel400willashanddisplaysteadygreen.
4. PressandreleasetheloadbuttonontheModel400toinitiatethermwareupdate.TheLEDonmodel
400willashslowly.IftheLEDdisplaysfastashesitmeansthermwareupdatewasunsuccessful.
5. Theupdatewilltakeapproximately4.5minutesandwhencompletetheLEDontheModel400will
display steady green.
6. PressandreleasetheRESETswitchthenremovetheUSBashdriveandModel400assembly.For
additionalinformationseeModel400USBFlashModuleInstallationGuide(LT-1402).
Digital Monitoring Products XTLC Installation Guide
8
COMPLIANCE
Listed Compliance Specications
15.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstalling
theXTLCinaccordancewithanyoftheANSIorSIAburglarystandards.Additionalspecicationsmaybe
required by a particular standard.
15.2 Use Marking
CommercialCentralStation,HouseholdBurglarandFireControlUnit.
15.3 NFPA 72
ThisequipmentshouldbeinstalledinaccordancewithChapter11oftheNationalFireAlarmCode,
ANSI/NFPA72-2002,(NationalFireProtectionAssociation,BatterymarchPark,Quincy,MA02269).Printed
information describing proper installation, operation, testing, maintenance, evacuation planning, and repair
serviceistobeprovidedwiththisequipment.Warning:Owner’sinstructionnotice,nottoberemovedby
anyone except occupant.
15.4 Types Of Service
SuitableforCentralStationCellular.SuitableforHouseholdFireandHouseholdBurglary.Testweekly.
15.5 Bypass Reports
ThebypassreportsmustbeprogrammedasYESforalllistedburglaryapplications.
15.6 Battery Standby
TheXTLCisshippedwithabatteryfor24hourbatterystandbyoperation.
Household Burglar-Alarm System Units
ANSI/UL 1023
16.1 Bell Cutoff
Thebellcutofftimecannotbelessthan4minutes.
16.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan45seconds.
16.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
16.4 Wireless External Contact
Whenused,theExternalContactof1101,1102,or1106transmittersmustbeprogrammedNormallyClosed.
16.5 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).
16.6 Wireless Audible Annunciation
TheWirelessAudibleoptionmustbeselectedasDAYforresidentialapplications.
16.7 Panel location
Mountpanelinsideprotectedarea.
16.8 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
XTLC Installation Guide Digital Monitoring Products
9
COMPLIANCE
Central Station Burglar Alarm Units
ANSI/UL 1610
17.1 Supervision
CommercialBurglaryisprovidedwhentheCellCheck-inandFailTimetimeissetto3minutes.
Note:TheSecureComWirelesstextplanselectedforthepanelshouldmatchorexceedtheprogrammed
MonthlyLimitoradditionalcellularchargesmayapply.
17.2 Remote Disarm
REMOTEDISARMmustbeprogrammedasNO.
17.3 Central Station
MESSAGETOTRANSMITprogrammingforzonesmustnotbesettoLOCAL(L).
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specications
18.1 Bell Output Denition
ThewirelesssirenoftheXTLCpanelmustbeprogrammedtooperatesteadyonburglaryalarmsand
temporalonrealarms.SeetheXTLCProgrammingGuide(LT-1108).
18.2 Household System
An alarm sounding device must be installed indoors so that it is clearly heard in all sleeping areas.
18.3 Wireless Supervision Time
TheZoneInformationSupervisionTimemustbe3minutesforredevices.SeetheXTLCProgrammingGuide.
18.4 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
18.5 Wired Modules
ModulesthatconnecttothePROGheader,suchasthe738Z,mustnotbeusedsincethebatterystandby
timewillbereducedbelowthe24hourminimum.
Digital Monitoring Products XTLC Installation Guide
10
COMPLIANCE
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
19.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-1108
SECTION #
REQUIREMENT RANGE SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1ExitTime 8.6ExitDelay Required
(Programmable) 45sec.-250sec. 60
Seconds 60 Seconds
4.2.2.2Progress
Annunciation 13.13PrewarnAddress Allowed Individualkeypadsmay
bedisabledperzone
All
keypads
enabled
Allkeypadsenabled
4.2.2.3ExitTimeRestart 8.6ExitDelay RequiredOption For re-entry during exit
time Enabled Enabled
4.2.2.5AutoStayArmon
UnvacatedPremises
8.15OccupiedPremise
-SeeInstallGuide
RequiredOption
(exceptfor
remotearming)
OccupiedPremiseNO/
YESoption Enabled
EnabledYes
for Residential
Applications
4.2.4.4ExitTimeand
Progress Annunciation/
Disable-forRemoteArm
NotAvailableon
Remote Arming AllowedOption
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1EntryDelay(s) 8.5EntryDelay
Required
(Programmable)
OnlyuseEntry
Delay1.Donot
useEntryDelay2.
30sec.–240Sec.** 30
Seconds
Atleast30
Seconds **
4.2.5.1AbortWindow–
forNon-FireZones 3.3TransmitDelay RequiredOption Disablebyzoneorzone
type
Enabled
NTDYEX
Zone
Enabled
4.2.5.1AbortWindow
Time–forNon-FireZones 3.3TransmitDelay Required
(Programmable)
20sec.,30sec.,or
40sec.**
30
Seconds
Atleast20
Seconds **
4.2.5.1.2Abort
Annunciation 3.3TransmitDelay RequiredOption Annunciate that no
alarm was transmitted Yes Yes
4.2.5.4.1Cancel
Annunciation
AlwaysEnabled-Not
Programmable RequiredOption
Annunciate that a
Cancel was transmitted
(S49)
Always
Enabled Yes
4.2.6.1&4.2.6.2Duress
Feature
UserCode+1=
AmbushCodeNot
Available
AllowedOption
No1+derivativeof
another user code/no
duplicates with other
user codes
Code+1
Always
Disabled
NotProgrammable
4.3.1CrossZoning 13.16CrossZone RequiredOption Yes/NoZone
Programming No
Enabledusing
two or more
programmedzones
4.3.1ProgrammableCross
Zoning Time 8.7CrossZoneTime Allowed 4sec.-250sec. 0 Seconds Perwalkpathin
protected premises
4.3.2SwingerShutdown NotAvailable—Always
On Required 1-6 trips 2trips 2trips
4.3.2SwingerShutdown
Disable 13.12SwingerBypass Allowed For non-police response
zones Yes Enabled(allzones)
4.3.3FireAlarm
Verication 13.5ZoneType RequiredOption FV Type Zone No
Yes as required
(unlesssensorscan
selfverify)
4.6.3SystemTest 16.6WalkTest Allowed Test all protection
devices N/A N/A
4.6.5Communications 16.6WalkTest NotAllowed N/A N/A N/A
*Programmingatinstallationmaybesubordinatetootherlistedrequirementsfortheintendedapplication.
**ForlistedInstallations,combinedEntryDelayandTransmitDelayshouldnotexceed1minute.
LocalBell
Allnon-rezonessuchasNight,Day,Exit,Aux1andAux2mustbeprogrammedforlocalbellenabledwithabellcutofftimeset
toaminimumof6minutestoprovideacancelwindowof5minutesorgreater.Thisdoesnotapplytomanuallyoperatedzone
typessuchasPanicandEmergency.
TherequirementsaresupersededbyanyrequirementsforCommercialBurglar,HouseholdFireWarning,orHouseholdBurglar
applications.
MinimumInstallationRequirements:SIACP-01-2010minimumsysteminstallationrequirementsincludeanXTLC,an1135Wireless
Siren,a9000SeriesWirelesskeypad,andcommunicationtoanSCS-1Rreceiver.
XTLC Installation Guide Digital Monitoring Products
11
REVISIONS
Revisions to This Document
Revisions
This section explains the changes that were made to this document during this revision. This section lists the
version,sectionnumberwithheading,andaquicksummaryofthechange.
Ver. SectionNumberandHeading SummaryofChanges
1.06 18.3WirelessExternalContact Removed1101,1102,and1105section
1.05 Entiredocument AddedreferencestoXTL/XTLC
 3.1AccessoryDevices  Addedreferencefor1135DBSiren
9.1ProgrammingConnection AddedreferenceforInstallingthe738Z
 18.5WiredModules  Added738Zreference
1.04 3.1AccessoryDevices  Addedreferencefor1184COdetectorand738Zmodule
1.03 3.1AccessoryDevices  Addedreferencesfor1183-135Fand183-135R
1.02 19.1FalseAlarmReduction UpdatedforSIACP-01-2010,4.3.2SwingerShutdownrange
     Added4.3.1CrossZoning,4.3.3FireAlarmVerication,
     4.6.3SystemTest,4.6.5Communication
1.01 2.3ComplianceInstruction Addedsection
 3.1AccessoryDevices  Addedreferencetoproductsnotforuseinlistedinstallations,
     added1161,1162SmokeDetectors
4.2MountingtheEnclosure Addedreferencetominimumseparationofpanel/transmitters
 5.1DCInput   Updatedpowercircuitrequirementonstep3
 6.2Replacement  AddedgureandreferencetoremovePCBscrewsifinstalled
15.1-15.6ListedCompliance Addedsections
16.1 - 16.8 Household Burglar Added sections
17.1-17.3CentralStation Addedsections
18.1 - 18.5 Household Fire Added sections
19.1ANSI/SIACP-01-2007 Addedsection
 ListingsandApprovals  AddedETLandUnderwritersLaboratorieslistings
800-641-4282
INTRUSION FIRE ACCESS NETWORKS
www.dmp.com 2500 North Partnership Boulevard
Designed, Engineered and
Assembled in U.S.A. Springeld, Missouri 65803-8877
LT-1105 1.06 © 2016 Digital Monitoring Products, Inc.
16144
Certications
ANSI/SIACP-01FalseAlarmReduction
ANSI/UL1023 HouseholdBurglar
ANSI/UL985 HouseholdFireWarning
ANSI/UL1610 CentralStationBurglar(Cellular)
CaliforniaStateFireMarshall(CSFM)
FCCWirelessApprovals
FCCPart15ID:CCKPC0117
IndustryCanadaID:5251A-PC0117
FCCCellularApprovalsforXTLC
CellularFCCPart15:MIVCNN0301
CellularIndustryCanada:4160A-CNN0301
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Digital Monitoring Products XTLC User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI