  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp - Gypsum fibre element User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application sheet
SpeedUp
Carpet / tiles / parquet / laminate / synthetics
Gypsum bre element (Fermacell)
1
2
3
4
5
1 Carpet / tiles / parquet
2 Gypsum bre element (Fermacell) 20 mm
3 SpeedUp heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 SpeedUp perimeter insulation
6 If necessary, vapour seal / impact sound
insulation.
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 50 mm Height excluding oor nish
Weight ~ 28 kg / m² Weight excluding oor nish
Thermal resistance R 0,86 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 0,97 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,5 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 14 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3. Oce spaces, hallways in oce
buildings, medical oces, stations and spaces with human occupancy, and commercial
spaces with oor areas up to 50 m² in residential or oce buildings. Corresponds to
categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
This construction applies to residential partition slabs between rooms at the same tem-
perature. No additional insulation is necessary. See “Overview of maximum additional
insulation” with regard to allowable equalisation insulation.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 5
Technical Data Floors/ceilings between rooms at the same temperature
6
© Danfoss 11/2008
VA.CR.A1.02